Potential Evapotranspiration (Thornthwaite)

The Thornthwaite method estimates monthly potential evapotranspiration primarily from mean monthly air temperature and an annual heat index. It also includes corrections for daylight duration and month length.

\(PET_{m} = 16(L/12)(N/30)(10T_{m}/I)a\)

What this formula means

The Thornthwaite method estimates monthly potential evapotranspiration primarily from mean monthly air temperature and an annual heat index. It also includes corrections for daylight duration and month length.

Scientific principle

Principle

The Thornthwaite method uses air temperature as an empirical indicator of the thermal energy available for evapotranspiration. It calculates an annual temperature-based heat index and uses it to estimate monthly potential evapotranspiration under standardized climatic assumptions.

Derivation

  • 1. Calculate the monthly heat-index contribution for each month using the mean monthly temperature.

  • 2. Sum the monthly contributions to obtain the annual heat index I.

  • 3. Calculate the empirical exponent a from I.

  • 4. Estimate the uncorrected monthly potential evapotranspiration using 16(10Tₘ/I)ᵃ.

  • 5. Apply the daylight-duration correction L/12, where L is average daylight duration in hours.

  • 6. Apply the month-length correction N/30, where N is the number of days in the month.

  • 7. The corrected result is the estimated monthly potential evapotranspiration.

Final Result

PETₘ = 16(L/12)(N/30)(10Tₘ/I)ᵃ

Annual Heat Index

I = Σ[(Tᵢ/5)¹·⁵¹⁴] for months with Tᵢ > 0°C

Empirical Exponent

a = 6.75 × 10⁻⁷I³ − 7.71 × 10⁻⁵I² + 1.792 × 10⁻²I + 0.49239

Interpretation

The method estimates potential rather than actual evapotranspiration and is based mainly on temperature and astronomical daylight information.

Variables and their meanings

SymbolMeaningUnit

PETₘ

Corrected potential evapotranspiration for the month

mm/month

L

Average daylight duration for the month

hours/day

N

Number of days in the month

Days

Tₘ

Mean monthly air temperature

°C

I

Annual temperature-based heat index

Dimensionless

Tᵢ

Mean temperature for month i, included when positive

°C

a

Empirical exponent calculated from annual heat index

Dimensionless

SI units and conversions

Potential Evapotranspiration

mm/month

Temperature

°C

Daylight Duration

hours/day

Month Length

Days

Heat Index

Dimensionless

Empirical Exponent

Dimensionless

Conditions of use

  • The method is conventionally applied to monthly mean temperatures.

  • Only positive monthly temperatures contribute to the conventional annual heat-index calculation.

  • The annual heat index must be calculated using the full set of relevant monthly temperature data.

  • The daylight-duration correction must correspond to the location and month.

  • The month-length correction must use the actual number of days in the month.

  • Temperature must be expressed in degrees Celsius.

Limitations and assumptions

  • The method is empirical and primarily temperature-based.

  • It does not explicitly account for wind speed, humidity, or measured solar radiation.

  • It may be less accurate in arid, high-altitude, or unusual climatic environments.

  • Potential evapotranspiration is not identical to actual evapotranspiration when soil water is limited.

  • The result depends on the accuracy of the monthly temperature series and daylight correction.

Step-by-step worked examples

ProblemSolutionAnswer

For an illustrative month, assume annual heat index I = 40, empirical exponent a = 1.0, mean monthly temperature Tₘ = 20°C, daylight duration L = 12 hours/day, and month length N = 30 days. Calculate monthly potential evapotranspiration.

  • Given: I = 40.

  • a = 1.0.

  • Tₘ = 20°C.

  • L = 12 hours/day.

  • N = 30 days.

  • PETₘ = 16(L/12)(N/30)(10Tₘ/I)ᵃ.

  • PETₘ = 16(12/12)(30/30)(200/40)¹.

  • PETₘ = 16 × 1 × 1 × 5.

  • PETₘ = 80 mm/month.

The estimated monthly potential evapotranspiration is 80 mm/month.

An illustrative month has I = 50, a = 1.2, Tₘ = 25°C, L = 14 hours/day, and N = 31 days. Calculate monthly potential evapotranspiration.

  • Given: I = 50.

  • a = 1.2.

  • Tₘ = 25°C.

  • L = 14 hours/day.

  • N = 31 days.

  • PETₘ = 16(14/12)(31/30)(250/50)¹·².

  • Temperature-index term = 5¹·² ≈ 6.8986.

  • Daylight correction = 14/12 ≈ 1.1667.

  • Month-length correction = 31/30 ≈ 1.0333.

  • PETₘ ≈ 16 × 1.1667 × 1.0333 × 6.8986.

  • PETₘ ≈ 133.5 mm/month.

The estimated monthly potential evapotranspiration is approximately 133.5 mm/month.

Real-world applications

  • Long-term climatic water-balance studies

  • Historical evapotranspiration estimation

  • Regional drought assessment

  • Hydrological modeling

  • Climate classification research

  • Water-resource studies with limited meteorological data