The bandwidth of a resonant circuit is the difference between its upper and lower half-power frequencies. For a conventional second-order resonant response, bandwidth equals resonant frequency divided by quality factor.

\(BW = f_{2} - f_{1} = f_{0}/Q\)

What this formula means

The bandwidth of a resonant circuit is the difference between its upper and lower half-power frequencies. For a conventional second-order resonant response, bandwidth equals resonant frequency divided by quality factor.

Scientific principle

Principle

A resonant circuit responds strongly near its resonant frequency. The bandwidth describes the frequency range over which the response remains above the half-power threshold. The quality factor measures how sharply the circuit responds around resonance.

Derivation

  • Let f₁ represent the lower half-power frequency.

  • Let f₂ represent the upper half-power frequency.

  • Bandwidth is defined as BW = f₂ − f₁.

  • For a conventional second-order resonator, quality factor is Q = f₀/BW.

  • Rearranging gives BW = f₀/Q.

  • For a series RLC circuit, Q = ω₀L/R = 1/(ω₀CR).

  • Therefore, BW = R/(2πL) in hertz for an ideal series RLC circuit.

Final Result

BW = f₂ − f₁ = f₀/Q. For an ideal series RLC circuit, BW = R/(2πL).

Variables and their meanings

BW

Bandwidth.

F₁

Lower half-power frequency.

F₂

Upper half-power frequency.

F₀

Resonant frequency.

Q

Quality factor.

R

Series resistance.

L

Inductance.

C

Capacitance.

SI units and conversions

BW

Hz.

F₁

Hz.

F₂

Hz.

F₀

Hz.

Q

Dimensionless.

R

Ω.

L

H.

C

F.

Conditions of use

  • The lower and upper frequencies must be defined using the same half-power criterion.

  • The resonator should behave approximately as a second-order system.

  • The equation BW = f₀/Q applies when Q is defined using the corresponding resonant bandwidth.

  • For the series RLC expression, the circuit must use the ideal series topology.

Limitations and assumptions

  • The formula does not describe arbitrary filter bandwidth definitions.

  • Loaded and unloaded quality factors may differ.

  • Component tolerances and parasitic losses affect practical bandwidth.

  • The exact response shape depends on circuit topology and measurement convention.

  • The approximation should not be applied indiscriminately to multi-resonant systems.

Step-by-step worked examples

ProblemSolutionAnswer

A resonant circuit has f₀ = 1000 Hz and quality factor Q = 20. Calculate bandwidth.

  • BW = f₀/Q.

  • BW = 1000/20.

  • BW = 50 Hz.

Bandwidth = 50 Hz.

A resonant circuit has lower half-power frequency f₁ = 900 Hz and upper half-power frequency f₂ = 1100 Hz. Calculate bandwidth.

  • BW = f₂ − f₁.

  • BW = 1100 − 900.

  • BW = 200 Hz.

Bandwidth = 200 Hz.

Real-world applications

  • Designing radio and communication filters.

  • Analyzing frequency-selective circuits.

  • Determining resonator selectivity.

  • Designing band-pass and band-stop networks.

  • Studying quality factor and energy losses.