✦ScienexySCIENCE KNOWLEDGE LIBRARY
General science · SCI-FORM-ENG-1508

Admittance of a Parallel RLC Circuit

The total admittance of an ideal parallel RLC circuit is the sum of its conductance and complex susceptance. Admittance is the reciprocal of impedance.

\(Y = 1/R + j(\omega C - 1/(\omega L))\)

What this formula means

The total admittance of an ideal parallel RLC circuit is the sum of its conductance and complex susceptance. Admittance is the reciprocal of impedance.

Scientific principle

Principle

In a parallel circuit, all branches share the same voltage and their currents add. Admittance provides a convenient representation because branch admittances add directly.

Derivation

  • For the resistor branch, admittance is Y_R = 1/R.

  • For the capacitor branch, admittance is Y_C = jωC.

  • For the inductor branch, admittance is Y_L = 1/(jωL) = −j/(ωL).

  • The total parallel admittance is the sum of branch admittances.

  • Therefore, Y = Y_R + Y_C + Y_L.

  • Substituting gives Y = 1/R + jωC − j/(ωL).

  • Combining the imaginary terms gives Y = 1/R + j(ωC − 1/(ωL)).

Final Result

Y = G + jB = 1/R + j(ωC − 1/(ωL)).

Variables and their meanings

Y

Complex admittance.

G

Conductance.

B

Susceptance.

R

Parallel resistance.

L

Inductance.

C

Capacitance.

Ω

Angular frequency.

J

Imaginary unit.

SI units and conversions

Y

S.

G

S.

B

S.

R

Ω.

L

H.

C

F.

Ω

rad·s⁻¹.

Conditions of use

  • The resistor, capacitor and inductor must be connected in parallel across the same two nodes.

  • The circuit is analyzed in sinusoidal steady state.

  • The components are assumed ideal and linear.

  • All branch quantities must use the same angular frequency.

Limitations and assumptions

  • Parasitic resistance and inductance are not included unless added to the model.

  • Real capacitors and inductors have frequency-dependent losses.

  • The formula does not describe switching transients.

  • A practical network with additional branches requires their admittances to be included.

Step-by-step worked examples

ProblemSolutionAnswer

An ideal parallel RLC circuit has R = 100 Ω, L = 0.1 H, C = 100 μF and ω = 100 rad·s⁻¹. Calculate its admittance.

  • Y = 1/R + j(ωC − 1/(ωL)).

  • G = 1/100 = 0.01 S.

  • ωC = 100 × 0.0001 = 0.01 S.

  • 1/(ωL) = 1/(100 × 0.1) = 0.1 S.

  • Y = 0.01 + j(0.01 − 0.1).

  • Y = 0.01 − j0.09 S.

Y = 0.01 − j0.09 S.

A parallel RLC model has R = 200 Ω, L = 0.5 H, C = 20 μF and ω = 500 rad·s⁻¹. Calculate Y.

  • G = 1/200 = 0.005 S.

  • ωC = 500 × 20 × 10⁻⁶ = 0.01 S.

  • 1/(ωL) = 1/(500 × 0.5) = 0.004 S.

  • Y = 0.005 + j(0.01 − 0.004).

  • Y = 0.005 + j0.006 S.

Y = 0.005 + j0.006 S.

Real-world applications

  • Analyzing parallel resonant circuits.

  • Designing electrical filters.

  • Studying conductance and susceptance.

  • Calculating current in parallel AC branches.

  • Analyzing power-system shunt components.

Formula Meaning

The total admittance of an ideal parallel RLC circuit is the sum of its conductance and complex susceptance. Admittance is the reciprocal of impedance.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source