Reactive power describes the rate of energy exchange between an AC source and reactive circuit elements such as inductors and capacitors. For sinusoidal steady-state conditions, it is the product of RMS voltage, RMS current and the sine of their phase difference.
Reactive Power
Reactive power describes the rate of energy exchange between an AC source and reactive circuit elements such as inductors and capacitors. For sinusoidal steady-state conditions, it is the product of RMS voltage, RMS current and the sine of their phase difference.
\(Q = V_{rms} I_{rms} \sin \phi\)
What this formula means
Scientific principle
Principle
Inductors and capacitors store energy temporarily in magnetic and electric fields and return that energy to the circuit. This alternating energy exchange contributes reactive power but does not represent net energy conversion over a complete cycle in an ideal reactive element.
Derivation
For sinusoidal steady-state operation, apparent power magnitude is S = VᵣₘₛIᵣₘₛ.
The complex power is S̃ = P + jQ.
The phase angle between voltage and current is φ.
The real component is P = VᵣₘₛIᵣₘₛ cos φ.
The imaginary component is Q = VᵣₘₛIᵣₘₛ sin φ.
Therefore, reactive power is Q = VᵣₘₛIᵣₘₛ sin φ.
Under the passive sign convention, inductive loads normally have positive Q and capacitive loads normally have negative Q.
Final Result
Q = VᵣₘₛIᵣₘₛ sin φ, with sign determined by the adopted power convention.
Variables and their meanings
Q
Reactive power.
Vᵣₘₛ
RMS voltage.
Iᵣₘₛ
RMS current.
Φ
Voltage-current phase angle.
P
Average real power.
S̃
Complex power.
S
Apparent power magnitude.
SI units and conversions
Q
var.
Vᵣₘₛ
V.
Iᵣₘₛ
A.
Φ
rad or degrees.
P
W.
S
VA.
Conditions of use
Voltage and current should be sinusoidal and at the same frequency.
RMS voltage and current values must be used.
The phase angle must be defined consistently.
The passive sign convention should be stated when assigning positive or negative reactive power.
Limitations and assumptions
For nonsinusoidal waveforms, the simple sine formula does not capture all reactive and distortion-related effects.
Reactive power is not equivalent to real energy consumption.
Different engineering standards may use different sign conventions.
The formula describes steady-state sinusoidal operation, not switching transients.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A sinusoidal AC circuit has RMS voltage 230 V, RMS current 5 A and power factor angle 36.87°. Calculate reactive power. |
| Reactive power magnitude = 690 var. Its sign depends on whether the load is inductive or capacitive. |
A theoretical AC circuit has RMS voltage 120 V, RMS current 3 A and phase angle 30°. Calculate reactive power. |
| Reactive power magnitude = 180 var. |
Real-world applications
Analyzing inductive and capacitive AC loads.
Power-factor correction studies.
Designing capacitor banks and reactive compensation systems.
Understanding power flow in electrical grids.
Evaluating apparent, real and reactive power relationships.
Formula Meaning
Reactive power describes the rate of energy exchange between an AC source and reactive circuit elements such as inductors and capacitors. For sinusoidal steady-state conditions, it is the product of RMS voltage, RMS current and the sine of their phase difference.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.