The Zener diode current is the current supplied through the series resistor minus the current drawn by the load. The equation describes a regulated Zener-diode circuit operating in its reverse-breakdown region.
Zener Diode Current
The Zener diode current is the current supplied through the series resistor minus the current drawn by the load. The equation describes a regulated Zener-diode circuit operating in its reverse-breakdown region.
\(I_{\mathrm{Z}} = (V_{\mathrm{S}} - V_{\mathrm{Z}})/R_{\mathrm{S}} - I_{\mathrm{L}}\)
What this formula means
Scientific principle
Principle
A reverse-biased Zener diode maintains an approximately constant voltage across itself when it operates within its specified breakdown-current range. A series resistor limits the total current and protects the diode.
Derivation
1. Let V_S be the DC supply voltage, V_Z the Zener voltage, and R_S the series resistance.
2. By Ohm’s law, the current through the series resistor is I_S = (V_S − V_Z)/R_S.
3. At the circuit node, Kirchhoff’s Current Law gives I_S = I_Z + I_L.
4. Rearranging gives the Zener current: I_Z = I_S − I_L.
5. Substituting the resistor-current expression gives the final relation.
Final Result
I_Z = (V_S − V_Z)/R_S − I_L
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
I_Z | Zener diode reverse current | A |
V_S | Supply voltage | V |
V_Z | Zener breakdown voltage | V |
R_S | Series current-limiting resistance | Ω |
I_L | Load current | A |
I_S | Current through the series resistor | A |
SI units and conversions
Current
A
Voltage
V
Resistance
Ω
Dimensional Formula
Current: [I]; voltage: [M L² T⁻³ I⁻¹]; resistance: [M L² T⁻³ I⁻²]
Conditions of use
The Zener diode must be reverse-biased and operating in its breakdown region.
The supply voltage must be greater than the Zener voltage for positive series current.
The calculated Zener current must remain within the diode's specified operating-current range.
The diode's power dissipation must not exceed its rated limit.
The series resistor must be included to limit current.
Limitations and assumptions
The equation assumes an approximately constant Zener voltage.
Real Zener diodes have dynamic resistance, so their voltage changes slightly with current.
The diode may leave its regulation region if the load current becomes too high or the supply voltage becomes too low.
Temperature changes can affect the Zener voltage.
The equation alone does not verify the diode's power rating; P_Z = V_Z I_Z must also be considered.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A Zener regulator has a 12 V supply, a 5.1 V Zener diode, a 330 Ω series resistor, and a load current of 10 mA. Calculate the Zener current. |
| The Zener current is approximately 10.91 mA. |
A Zener regulator has V_S = 15 V, V_Z = 6 V, R_S = 450 Ω, and I_L = 8 mA. Determine the Zener current. |
| The Zener current is 12 mA. |
Real-world applications
Shunt voltage regulators
Reference-voltage circuits
Overvoltage protection circuits
Voltage-clamping networks
Input protection in electronic equipment
Formula Meaning
The Zener diode current is the current supplied through the series resistor minus the current drawn by the load. The equation describes a regulated Zener-diode circuit operating in its reverse-breakdown region.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.