BJT transconductance measures how strongly a small change in base-emitter voltage changes the collector current at a specified operating point. For an ideal BJT in forward-active operation, it equals collector current divided by thermal voltage.
BJT Transconductance
BJT transconductance measures how strongly a small change in base-emitter voltage changes the collector current at a specified operating point. For an ideal BJT in forward-active operation, it equals collector current divided by thermal voltage.
\(g_{\mathrm{m}} = I_{\mathrm{C}}/V_{\mathrm{T}} = I_{\mathrm{C}} q/(k_{\mathrm{B}} T)\)
What this formula means
Scientific principle
Principle
The collector current of an ideal BJT in forward-active operation depends exponentially on base-emitter voltage. Differentiating this exponential current-voltage relationship gives the small-signal transconductance.
Derivation
1. The ideal forward-active collector-current relation is I_C = I_S exp(V_BE/V_T), when the reverse-saturation contribution is negligible.
2. Transconductance is defined as the derivative of collector current with respect to base-emitter voltage: g_m = ∂I_C/∂V_BE.
3. Differentiating gives g_m = (I_S/V_T)exp(V_BE/V_T).
4. Since I_C = I_S exp(V_BE/V_T), substitution gives g_m = I_C/V_T.
5. Thermal voltage is V_T = k_B T/q.
6. Therefore, g_m = I_C q/(k_B T).
Final Result
g_m = I_C/V_T = I_C q/(k_B T)
Interpretation
A larger collector bias current produces a larger BJT transconductance at the same temperature.
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
g_m | Small-signal transconductance | S or A/V |
I_C | DC collector operating current | A |
V_T | Thermal voltage, V_T = k_B T/q | V |
k_B | Boltzmann constant | J/K |
T | Absolute temperature | K |
q | Magnitude of the elementary charge | C |
I_S | Reverse-saturation current parameter in the ideal BJT model | A |
SI units and conversions
Transconductance
S = A/V
Thermal Voltage
V
Temperature
K
Dimensional Formula
Transconductance: [M⁻¹ L⁻² T³ I²]
Conditions of use
The transistor should be operating in the forward-active region.
The collector current should be sufficiently above leakage-dominated levels for the ideal exponential approximation to be useful.
The operating temperature must be expressed in kelvin when calculating thermal voltage.
The result represents small-signal behaviour around a DC operating point.
The applied small-signal variation should be sufficiently small for linearization.
Limitations and assumptions
The formula assumes an ideal exponential BJT current-voltage relationship.
High-level injection, series resistance, recombination, and self-heating can change the practical result.
Transconductance is an operating-point quantity, not a fixed value for the transistor.
The formula does not directly describe large-signal transistor behaviour.
At approximately 300 K, V_T is about 25.85 mV; this value changes with temperature.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
An ideal BJT operates at a collector current of 2 mA at approximately 300 K. Using V_T = 25.85 mV, calculate its transconductance. |
| The transconductance is approximately 77.4 mS. |
A BJT has a collector current of 5 mA at a temperature where the thermal voltage is 26 mV. Determine its transconductance. |
| The transconductance is approximately 192.3 mS. |
Real-world applications
Small-signal BJT amplifier design
Differential amplifier analysis
Analog integrated-circuit design
Transistor gain estimation
Bias-point and frequency-response analysis
Formula Meaning
BJT transconductance measures how strongly a small change in base-emitter voltage changes the collector current at a specified operating point. For an ideal BJT in forward-active operation, it equals collector current divided by thermal voltage.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.