The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.
MOSFET Drain Current (Saturation Region)
The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.
\(I_{\mathrm{D}} = \frac{1}{2} \mu_{\mathrm{n}} C_{\mathrm{ox}} (W/L)(V_{\mathrm{GS}} - V_{\mathrm{TH}})^{2}\)
What this formula means
Scientific principle
Principle
As drain-source voltage increases, the inversion channel becomes progressively weaker near the drain. At the onset of saturation, the channel reaches pinch-off at the drain end. In the ideal long-channel model, further increases in drain voltage produce little change in drain current.
Derivation
1. Define the gate overdrive voltage as V_OV = V_GS − V_TH.
2. The triode-region current is I_D = μ_nC_ox(W/L)[V_OVV_DS − V_DS²/2].
3. At the ideal onset of saturation, V_DS = V_OV.
4. Substituting this condition gives I_D = μ_nC_ox(W/L)[V_OV² − V_OV²/2].
5. Simplifying gives I_D = ½μ_nC_ox(W/L)V_OV².
6. Replacing V_OV with V_GS − V_TH gives the final equation.
Final Result
I_D = ½ μ_n C_ox (W/L)(V_GS − V_TH)²
Region Condition
V_GS > V_TH and V_DS ≥ V_GS − V_TH
Channel Length Modulation Model
I_D ≈ ½ μ_n C_ox(W/L)(V_GS − V_TH)²(1 + λV_DS)
Note
The channel-length-modulation factor is an approximate practical correction; λ is the channel-length modulation parameter.
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
I_D | Drain current | A |
μ_n | Electron mobility | m²/(V·s) |
C_ox | Gate-oxide capacitance per unit area | F/m² |
W | Channel width | m |
L | Channel length | m |
V_GS | Gate-to-source voltage | V |
V_TH | Threshold voltage | V |
V_DS | Drain-to-source voltage | V |
λ | Channel-length modulation parameter | V⁻¹ |
SI units and conversions
Drain Current
A
Mobility
m²/(V·s)
Oxide Capacitance Per Area
F/m²
Voltage
V
Dimensional Formula
Drain current: [I]
Conditions of use
The formula is for a conventional long-channel n-channel enhancement MOSFET.
The gate-source voltage must exceed threshold voltage.
The drain-source voltage must satisfy V_DS ≥ V_OV.
The ideal equation assumes channel-length modulation is negligible.
The device must remain within its specified voltage, current, and power limits.
Limitations and assumptions
The ideal square-law equation assumes constant carrier mobility and a long channel.
Short-channel devices may exhibit velocity saturation and other effects that invalidate the simple square-law model.
Channel-length modulation causes practical drain current to increase with V_DS.
Body effect changes V_TH when the body-source voltage is nonzero.
Subthreshold conduction is not described by this saturation equation.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A long-channel nMOS has μ_nC_ox(W/L) = 2 mA/V², V_GS = 3 V, V_TH = 1 V, and V_DS = 3 V. Calculate the ideal saturation drain current. |
| The ideal saturation drain current is 4 mA. |
A MOSFET has μ_nC_ox(W/L) = 1.5 mA/V², V_GS = 5 V, V_TH = 2 V, and V_DS = 4 V. Find its ideal saturation current. |
| The ideal saturation drain current is 6.75 mA. |
Real-world applications
MOSFET amplifier design
CMOS logic transistor modelling
Analog integrated circuits
Current-source and current-mirror analysis
MOSFET operating-point calculations
Formula Meaning
The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.