✦ScienexySCIENCE KNOWLEDGE LIBRARY
General science · SCI-FORM-ENG-1527

MOSFET Drain Current (Saturation Region)

The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.

\(I_{\mathrm{D}} = \frac{1}{2} \mu_{\mathrm{n}} C_{\mathrm{ox}} (W/L)(V_{\mathrm{GS}} - V_{\mathrm{TH}})^{2}\)

What this formula means

The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.

Scientific principle

Principle

As drain-source voltage increases, the inversion channel becomes progressively weaker near the drain. At the onset of saturation, the channel reaches pinch-off at the drain end. In the ideal long-channel model, further increases in drain voltage produce little change in drain current.

Derivation

  • 1. Define the gate overdrive voltage as V_OV = V_GS − V_TH.

  • 2. The triode-region current is I_D = μ_nC_ox(W/L)[V_OVV_DS − V_DS²/2].

  • 3. At the ideal onset of saturation, V_DS = V_OV.

  • 4. Substituting this condition gives I_D = μ_nC_ox(W/L)[V_OV² − V_OV²/2].

  • 5. Simplifying gives I_D = ½μ_nC_ox(W/L)V_OV².

  • 6. Replacing V_OV with V_GS − V_TH gives the final equation.

Final Result

I_D = ½ μ_n C_ox (W/L)(V_GS − V_TH)²

Region Condition

V_GS > V_TH and V_DS ≥ V_GS − V_TH

Channel Length Modulation Model

I_D ≈ ½ μ_n C_ox(W/L)(V_GS − V_TH)²(1 + λV_DS)

Note

The channel-length-modulation factor is an approximate practical correction; λ is the channel-length modulation parameter.

Variables and their meanings

SymbolMeaningUnit

I_D

Drain current

A

μ_n

Electron mobility

m²/(V·s)

C_ox

Gate-oxide capacitance per unit area

F/m²

W

Channel width

m

L

Channel length

m

V_GS

Gate-to-source voltage

V

V_TH

Threshold voltage

V

V_DS

Drain-to-source voltage

V

λ

Channel-length modulation parameter

V⁻¹

SI units and conversions

Drain Current

A

Mobility

m²/(V·s)

Oxide Capacitance Per Area

F/m²

Voltage

V

Dimensional Formula

Drain current: [I]

Conditions of use

  • The formula is for a conventional long-channel n-channel enhancement MOSFET.

  • The gate-source voltage must exceed threshold voltage.

  • The drain-source voltage must satisfy V_DS ≥ V_OV.

  • The ideal equation assumes channel-length modulation is negligible.

  • The device must remain within its specified voltage, current, and power limits.

Limitations and assumptions

  • The ideal square-law equation assumes constant carrier mobility and a long channel.

  • Short-channel devices may exhibit velocity saturation and other effects that invalidate the simple square-law model.

  • Channel-length modulation causes practical drain current to increase with V_DS.

  • Body effect changes V_TH when the body-source voltage is nonzero.

  • Subthreshold conduction is not described by this saturation equation.

Step-by-step worked examples

ProblemSolutionAnswer

A long-channel nMOS has μ_nC_ox(W/L) = 2 mA/V², V_GS = 3 V, V_TH = 1 V, and V_DS = 3 V. Calculate the ideal saturation drain current.

  • Given: K = μ_nC_ox(W/L) = 2 mA/V².

  • Overdrive: V_OV = 3 − 1 = 2 V.

  • Region check: V_DS = 3 V ≥ 2 V, so saturation is satisfied.

  • I_D = ½K V_OV².

  • I_D = ½ × 2 × 2² mA.

  • I_D = 4 mA.

The ideal saturation drain current is 4 mA.

A MOSFET has μ_nC_ox(W/L) = 1.5 mA/V², V_GS = 5 V, V_TH = 2 V, and V_DS = 4 V. Find its ideal saturation current.

  • Overdrive: V_OV = 5 − 2 = 3 V.

  • Region check: 4 V ≥ 3 V, so the saturation condition is satisfied.

  • I_D = ½ × 1.5 × 3² mA.

  • I_D = 0.75 × 9 mA.

  • I_D = 6.75 mA.

The ideal saturation drain current is 6.75 mA.

Real-world applications

  • MOSFET amplifier design

  • CMOS logic transistor modelling

  • Analog integrated circuits

  • Current-source and current-mirror analysis

  • MOSFET operating-point calculations

Formula Meaning

The long-channel MOSFET saturation-region equation estimates drain current when the channel is pinched off near the drain and the drain-source voltage is at least as large as the gate overdrive voltage.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source