The ideal closed-loop voltage gain of an inverting operational-amplifier circuit is the negative ratio of feedback resistance to input resistance. The negative sign indicates a 180° phase inversion for sinusoidal signals within the circuit's operating bandwidth.
Op-Amp Closed-Loop Gain (Inverting)
The ideal closed-loop voltage gain of an inverting operational-amplifier circuit is the negative ratio of feedback resistance to input resistance. The negative sign indicates a 180° phase inversion for sinusoidal signals within the circuit's operating bandwidth.
\(A_{\mathrm{v}} = V_{\mathrm{out}}/V_{\mathrm{in}} = -R_{\mathrm{f}}/R_{\mathrm{in}}\)
What this formula means
Scientific principle
Principle
Negative feedback drives the inverting input voltage close to the non-inverting input voltage. When the non-inverting input is grounded, the inverting input becomes a virtual ground under ideal linear-operation assumptions.
Derivation
1. For an ideal op-amp operating with negative feedback, the input currents are approximately zero.
2. With the non-inverting input grounded, the inverting input is approximately at 0 V.
3. The current through the input resistor is I_in = V_in/R_in.
4. Since almost no current enters the op-amp input, the same current flows through the feedback resistor.
5. The feedback current is I_f = (0 − V_out)/R_f = −V_out/R_f.
6. Equating currents gives V_in/R_in = −V_out/R_f.
7. Rearranging gives V_out/V_in = −R_f/R_in.
Final Result
A_v = −R_f/R_in
Output Relation
V_out = −(R_f/R_in)V_in
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
A_v | Closed-loop voltage gain | Dimensionless |
V_out | Output voltage | V |
V_in | Input voltage | V |
R_f | Feedback resistance | Ω |
R_in | Input resistance | Ω |
SI units and conversions
Voltage Gain
Dimensionless
Resistance
Ω
Voltage
V
Dimensional Formula
Voltage gain: dimensionless
Conditions of use
The op-amp must operate with negative feedback.
The non-inverting input is assumed to be grounded.
The op-amp should remain within its linear output range and supply-voltage limits.
Input and feedback impedances are assumed to be resistive for the stated formula.
The input frequency should lie within the circuit's usable closed-loop bandwidth.
Limitations and assumptions
Real op-amps have finite open-loop gain and bandwidth.
Input offset voltage, input bias current, and finite input impedance can produce errors.
Output saturation occurs when the required output exceeds the available output-voltage range.
The gain becomes frequency-dependent when the op-amp's bandwidth and parasitic capacitances are considered.
The negative sign describes phase inversion; it does not mean that the gain magnitude is negative.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
An inverting amplifier has R_f = 100 kΩ and R_in = 10 kΩ. Calculate its closed-loop gain. |
| The closed-loop voltage gain is −10. |
An ideal inverting amplifier has R_f = 47 kΩ, R_in = 4.7 kΩ, and input voltage V_in = 0.2 V. Find its output voltage. |
| The ideal output voltage is −2 V, provided the op-amp can produce this voltage without saturation. |
Real-world applications
Signal inversion
Audio signal amplification
Sensor signal conditioning
Weighted summing amplifiers
Analog computing circuits
Formula Meaning
The ideal closed-loop voltage gain of an inverting operational-amplifier circuit is the negative ratio of feedback resistance to input resistance. The negative sign indicates a 180° phase inversion for sinusoidal signals within the circuit's operating bandwidth.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.