The slew rate of an operational amplifier is the maximum rate at which its output voltage can change with time. It is commonly expressed in volts per microsecond.
Op-Amp Slew Rate
The slew rate of an operational amplifier is the maximum rate at which its output voltage can change with time. It is commonly expressed in volts per microsecond.
\(SR = \max|dV_{\mathrm{out}}/dt|\)
What this formula means
Scientific principle
Principle
An operational amplifier has internal current and capacitance limitations. During large-signal transitions, the available internal current charges or discharges compensation capacitances at a limited rate, restricting the maximum output-voltage slope.
Derivation
1. The instantaneous output-voltage rate of change is dV_out/dt.
2. The slew rate is defined as the maximum magnitude of this rate.
3. Therefore, SR = max|dV_out/dt|.
4. For an approximately linear output transition, SR can be estimated as |ΔV_out|/Δt.
5. For a sinusoidal output V_out = V_p sin(2πft), the maximum slope is 2πfV_p.
6. To avoid slew-rate distortion, the required maximum slope must not exceed the specified slew rate.
Final Result
SR = max|dV_out/dt|
Sinusoidal Condition
SR_required = 2πfV_p ≤ SR
Maximum Frequency
f_max = SR/(2πV_p)
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
SR | Slew rate | V/s or V/μs |
V_out | Output voltage | V |
t | Time | s |
ΔV_out | Output-voltage change during a transition | V |
Δt | Time interval of the transition | s |
f | Sinusoidal signal frequency | Hz |
V_p | Peak output-voltage amplitude | V |
SI units and conversions
Slew Rate
V/s or V/μs
Frequency
Hz
Dimensional Formula
Slew rate: [M L² T⁻⁴ I⁻¹]
Conditions of use
The maximum output slope should be measured under specified load and supply conditions.
For a sinusoidal signal, V_p must represent peak amplitude rather than peak-to-peak voltage.
The sinusoidal condition assumes the amplifier is expected to reproduce the waveform without slew-rate limitation.
The output must remain within the permitted voltage swing.
The manufacturer's slew-rate specification should be used for a particular op-amp.
Limitations and assumptions
Slew rate is a large-signal limitation and is different from small-signal bandwidth.
The specified slew rate can depend on supply voltage, load capacitance, and operating conditions.
Meeting the slew-rate condition does not guarantee low distortion; bandwidth and other limitations must also be considered.
The formula does not describe all nonlinear distortion mechanisms.
For complex waveforms, the maximum instantaneous slope rather than only the fundamental frequency must be considered.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
An op-amp output changes by 10 V in 2 μs. Estimate the slew rate. |
| The estimated slew rate is 5 V/μs. |
An op-amp has a slew rate of 1 V/μs and must produce a sinusoidal output with a peak amplitude of 5 V. Estimate the maximum frequency allowed by the slew-rate condition. |
| The theoretical slew-rate-limited maximum frequency is approximately 31.8 kHz. |
Real-world applications
Audio amplifier design
High-speed signal processing
Waveform-generation circuits
Large-signal amplifier characterization
Operational-amplifier selection
Formula Meaning
The slew rate of an operational amplifier is the maximum rate at which its output voltage can change with time. It is commonly expressed in volts per microsecond.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.