✦ScienexySCIENCE KNOWLEDGE LIBRARY
General science · SCI-FORM-ENG-1544

Closed-Loop Transfer Function

The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.

\(T(s) = G(s)/[1 + G(s)H(s)]\)

What this formula means

The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.

Scientific principle

Principle

Negative feedback compares the reference input with a measured or estimated output signal. The resulting error is processed by the forward-path system, while the feedback path returns a portion of the output to the comparison point.

Derivation

  • 1. Let R(s) be the reference input and Y(s) the system output.

  • 2. For negative feedback, the error signal is E(s) = R(s) − H(s)Y(s).

  • 3. The forward-path relation is Y(s) = G(s)E(s).

  • 4. Substitute the error expression: Y(s) = G(s)[R(s) − H(s)Y(s)].

  • 5. Expand: Y(s) = G(s)R(s) − G(s)H(s)Y(s).

  • 6. Collect output terms: Y(s)[1 + G(s)H(s)] = G(s)R(s).

  • 7. Divide by R(s)[1 + G(s)H(s)] to obtain the closed-loop transfer function.

Final Result

T(s) = Y(s)/R(s) = G(s)/[1 + G(s)H(s)]

Unity Feedback Case

T(s) = G(s)/[1 + G(s)]

Characteristic Equation

1 + G(s)H(s) = 0

Variables and their meanings

SymbolMeaningUnit

T(s)

Closed-loop transfer function

Output unit divided by reference-input unit

G(s)

Forward-path transfer function

Depends on system signals

H(s)

Feedback-path transfer function

Depends on system signals

R(s)

Reference-input transform

Reference unit × s

Y(s)

Output transform

Output unit × s

E(s)

Error-signal transform

Error unit × s

SI units and conversions

Closed Loop Transfer Function

Depends on the reference and output quantities

Loop Gain

Dimensionless for a properly scaled feedback loop

Dimensional Formula

Depends on the physical input-output relationship

Conditions of use

  • The standard negative-feedback configuration must be used.

  • The forward and feedback paths must be represented by valid transfer functions.

  • The system is assumed to be linear and time-invariant.

  • Initial conditions are assumed to be zero when using transfer functions.

  • The feedback sign must be checked; positive feedback produces a different denominator.

Limitations and assumptions

  • The formula does not guarantee closed-loop stability.

  • Closed-loop poles are determined by the characteristic equation 1 + G(s)H(s) = 0.

  • Unmodelled delays and high-frequency dynamics can significantly affect stability.

  • The formula assumes that the system can be represented by the chosen linear models.

  • For multivariable systems, transfer functions become matrices and the scalar formula must be generalized.

Step-by-step worked examples

ProblemSolutionAnswer

A negative-feedback system has G(s) = 10/(s + 2) and unity feedback. Find its closed-loop transfer function.

  • Given: G(s) = 10/(s + 2), H(s) = 1.

  • Use: T(s) = G(s)/[1 + G(s)H(s)].

  • T(s) = [10/(s + 2)]/[1 + 10/(s + 2)].

  • Combine the denominator: 1 + 10/(s + 2) = (s + 12)/(s + 2).

  • T(s) = [10/(s + 2)] × [(s + 2)/(s + 12)].

  • T(s) = 10/(s + 12).

The closed-loop transfer function is T(s) = 10/(s + 12).

A system has forward gain G(s) = 5 and feedback gain H(s) = 0.2. Calculate its closed-loop gain.

  • Use: T = G/(1 + GH).

  • Substitute: T = 5/[1 + (5 × 0.2)].

  • T = 5/(1 + 1).

  • T = 5/2.

  • T = 2.5.

The closed-loop gain is 2.5.

Real-world applications

  • Feedback amplifier design

  • Motor-speed control

  • Temperature-control systems

  • Robotic control loops

  • Industrial process regulation

Formula Meaning

The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source