The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.
Closed-Loop Transfer Function
The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.
\(T(s) = G(s)/[1 + G(s)H(s)]\)
What this formula means
Scientific principle
Principle
Negative feedback compares the reference input with a measured or estimated output signal. The resulting error is processed by the forward-path system, while the feedback path returns a portion of the output to the comparison point.
Derivation
1. Let R(s) be the reference input and Y(s) the system output.
2. For negative feedback, the error signal is E(s) = R(s) − H(s)Y(s).
3. The forward-path relation is Y(s) = G(s)E(s).
4. Substitute the error expression: Y(s) = G(s)[R(s) − H(s)Y(s)].
5. Expand: Y(s) = G(s)R(s) − G(s)H(s)Y(s).
6. Collect output terms: Y(s)[1 + G(s)H(s)] = G(s)R(s).
7. Divide by R(s)[1 + G(s)H(s)] to obtain the closed-loop transfer function.
Final Result
T(s) = Y(s)/R(s) = G(s)/[1 + G(s)H(s)]
Unity Feedback Case
T(s) = G(s)/[1 + G(s)]
Characteristic Equation
1 + G(s)H(s) = 0
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
T(s) | Closed-loop transfer function | Output unit divided by reference-input unit |
G(s) | Forward-path transfer function | Depends on system signals |
H(s) | Feedback-path transfer function | Depends on system signals |
R(s) | Reference-input transform | Reference unit × s |
Y(s) | Output transform | Output unit × s |
E(s) | Error-signal transform | Error unit × s |
SI units and conversions
Closed Loop Transfer Function
Depends on the reference and output quantities
Loop Gain
Dimensionless for a properly scaled feedback loop
Dimensional Formula
Depends on the physical input-output relationship
Conditions of use
The standard negative-feedback configuration must be used.
The forward and feedback paths must be represented by valid transfer functions.
The system is assumed to be linear and time-invariant.
Initial conditions are assumed to be zero when using transfer functions.
The feedback sign must be checked; positive feedback produces a different denominator.
Limitations and assumptions
The formula does not guarantee closed-loop stability.
Closed-loop poles are determined by the characteristic equation 1 + G(s)H(s) = 0.
Unmodelled delays and high-frequency dynamics can significantly affect stability.
The formula assumes that the system can be represented by the chosen linear models.
For multivariable systems, transfer functions become matrices and the scalar formula must be generalized.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A negative-feedback system has G(s) = 10/(s + 2) and unity feedback. Find its closed-loop transfer function. |
| The closed-loop transfer function is T(s) = 10/(s + 12). |
A system has forward gain G(s) = 5 and feedback gain H(s) = 0.2. Calculate its closed-loop gain. |
| The closed-loop gain is 2.5. |
Real-world applications
Feedback amplifier design
Motor-speed control
Temperature-control systems
Robotic control loops
Industrial process regulation
Formula Meaning
The closed-loop transfer function of a standard negative-feedback system is the ratio of the forward-path transfer function to one plus the product of the forward-path and feedback-path transfer functions.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.