Closed-Loop Sensitivity Function

The closed-loop sensitivity function describes how the closed-loop error or sensitivity to certain disturbances and model variations depends on the open-loop loop gain. For a standard negative-feedback system, it is the reciprocal of one plus the loop transfer function.

\(S(s) = 1/[1 + L(s)]\)

What this formula means

The closed-loop sensitivity function describes how the closed-loop error or sensitivity to certain disturbances and model variations depends on the open-loop loop gain. For a standard negative-feedback system, it is the reciprocal of one plus the loop transfer function.

Scientific principle

Principle

Negative feedback reduces the effect of certain disturbances and parameter variations by comparing the output with the reference. The sensitivity function quantifies how strongly the closed-loop system responds to changes entering at specified locations in the feedback structure.

Derivation

  • 1. Define the loop transfer function as L(s) = G(s)H(s).

  • 2. For negative feedback, E(s) = R(s) − H(s)Y(s).

  • 3. Since Y(s) = G(s)E(s), substitute to obtain E(s) = R(s) − H(s)G(s)E(s).

  • 4. Rearrange: E(s)[1 + G(s)H(s)] = R(s).

  • 5. Divide by R(s): E(s)/R(s) = 1/[1 + G(s)H(s)].

  • 6. Define the sensitivity function as S(s) = 1/[1 + L(s)].

Final Result

S(s) = 1/[1 + L(s)]

Reference To Error Relation

E(s)/R(s) = S(s)

Plant Sensitivity Relation

For T(s) = L(s)/[1 + L(s)], the relative sensitivity of T to multiplicative changes in L is S(s), under the standard loop definition.

Variables and their meanings

SymbolMeaningUnit

S(s)

Closed-loop sensitivity function

Dimensionless

L(s)

Open-loop loop transfer function G(s)H(s)

Dimensionless for a properly scaled loop

G(s)

Forward-path transfer function

Depends on system signals

H(s)

Feedback-path transfer function

Depends on system signals

R(s)

Reference-input transform

Reference unit × s

E(s)

Error-signal transform

Error unit × s

SI units and conversions

Sensitivity Function

Dimensionless

Loop Gain

Dimensionless for a properly scaled loop

Dimensional Formula

Dimensionless

Conditions of use

  • The system must use the standard negative-feedback configuration.

  • The loop transfer function must be defined consistently as L(s) = G(s)H(s).

  • The system is assumed to be linear and time-invariant.

  • Transfer-function calculations assume zero initial conditions.

  • The disturbance or uncertainty location must be identified before interpreting a sensitivity response.

Limitations and assumptions

  • The sensitivity function does not have the same disturbance interpretation for every disturbance injection point.

  • A small sensitivity magnitude indicates reduced sensitivity in the corresponding defined relationship, not immunity to all disturbances.

  • High loop gain can improve low-frequency disturbance rejection but may reduce stability margins if poorly designed.

  • Unmodelled dynamics and delays can change the actual closed-loop response.

  • The equation alone does not establish stability.

Step-by-step worked examples

ProblemSolutionAnswer

A negative-feedback system has loop gain L(s) = 9 at a particular frequency. Calculate its sensitivity magnitude at that frequency.

  • Given: L = 9.

  • Use: S = 1/(1 + L).

  • S = 1/(1 + 9).

  • S = 1/10.

  • S = 0.1.

The sensitivity magnitude is 0.1 for this real positive loop-gain value.

At a particular frequency, the loop transfer function is L(jω) = 4. Determine the sensitivity function at that frequency.

  • Use: S(jω) = 1/[1 + L(jω)].

  • S(jω) = 1/(1 + 4).

  • S(jω) = 1/5.

  • S(jω) = 0.2.

The sensitivity function is 0.2 at the specified frequency.

Real-world applications

  • Feedback-controller robustness analysis

  • Disturbance-rejection design

  • Control-system model uncertainty analysis

  • Precision motion-control systems

  • Industrial process regulation

Formula Meaning

The closed-loop sensitivity function describes how the closed-loop error or sensitivity to certain disturbances and model variations depends on the open-loop loop gain. For a standard negative-feedback system, it is the reciprocal of one plus the loop transfer function.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.