Complementary Sensitivity Function
The complementary sensitivity function describes the closed-loop transfer relationship associated with the loop gain in a standard negative-feedback system. It is commonly used to analyze reference tracking and the transmission of certain measurement disturbances and high-frequency noise.
\(T(s) = L(s)/[1 + L(s)]\)
What this formula means
Scientific principle
Principle
A feedback-control system divides its response between the sensitivity function and the complementary sensitivity function. The complementary sensitivity function describes how the loop gain is transmitted through the closed-loop system.
Derivation
1. Define the loop transfer function as L(s) = G(s)H(s).
2. The standard negative-feedback closed-loop transfer function is T(s) = G(s)/[1 + G(s)H(s)] when the output is measured before the feedback block.
3. Multiplying the transfer function by H(s) gives H(s)T(s) = G(s)H(s)/[1 + G(s)H(s)].
4. Substitute L(s) = G(s)H(s).
5. The complementary sensitivity function is therefore T_c(s) = L(s)/[1 + L(s)].
6. Since S(s) = 1/[1 + L(s)], their sum is S(s) + T_c(s) = 1.
Final Result
T_c(s) = L(s)/[1 + L(s)]
Sensitivity Identity
S(s) + T_c(s) = 1
Unity Feedback Case
For H(s) = 1, T_c(s) = G(s)/[1 + G(s)].
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
T_c(s) | Complementary sensitivity function | Dimensionless |
L(s) | Open-loop loop transfer function G(s)H(s) | Dimensionless for a properly scaled loop |
S(s) | Sensitivity function | Dimensionless |
G(s) | Forward-path transfer function | Depends on system signals |
H(s) | Feedback-path transfer function | Depends on system signals |
SI units and conversions
Complementary Sensitivity
Dimensionless
Loop Gain
Dimensionless for a properly scaled loop
Dimensional Formula
Dimensionless
Conditions of use
The standard negative-feedback loop structure must be used.
The loop transfer function must be defined as L(s) = G(s)H(s).
The relationship must use a consistent output and feedback measurement convention.
The system is assumed to be linear and time-invariant.
Transfer-function calculations assume zero initial conditions.
Limitations and assumptions
The physical interpretation of T_c depends on where disturbances enter the feedback system.
A small complementary sensitivity magnitude does not imply good reference tracking at that frequency.
High-frequency measurement noise can be transmitted through the complementary sensitivity path.
The identity S + T_c = 1 is algebraic and does not itself guarantee stability.
Trade-offs between tracking, disturbance rejection, noise attenuation, and robustness must be considered together.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A control system has loop gain L(s) = 4 at a particular frequency. Calculate its complementary sensitivity and sensitivity values. |
| The complementary sensitivity is 0.8 and the sensitivity is 0.2. |
A feedback system has loop gain L = 19 at a specified frequency. Determine its complementary sensitivity. |
| The complementary sensitivity is 0.95. |
Real-world applications
Reference-tracking analysis
Measurement-noise transmission analysis
Robust control design
Feedback-loop bandwidth design
Control-system sensitivity trade-off analysis
Formula Meaning