For a stable unity-feedback system with a unit-step reference input, the steady-state error is the reciprocal of one plus the position error constant K_p, provided the final-value theorem conditions are satisfied.
Steady-State Error for Step Input
For a stable unity-feedback system with a unit-step reference input, the steady-state error is the reciprocal of one plus the position error constant K_p, provided the final-value theorem conditions are satisfied.
\(e_{\mathrm{ss}} = 1/(1 + K_{\mathrm{p}})\)
What this formula means
Scientific principle
Principle
A step input represents a constant reference command. In a unity-feedback system, the error is determined by the difference between the reference and output. The position error constant measures the low-frequency loop gain relevant to step tracking.
Derivation
1. For unity feedback, the error transform is E(s) = R(s)/[1 + G(s)].
2. A unit-step input has R(s) = 1/s.
3. Therefore, E(s) = 1/[s(1 + G(s))].
4. Using the final-value theorem, e_ss = limₜ→∞ e(t) = limₛ→₀ sE(s), provided the closed-loop error response satisfies the theorem's stability conditions.
5. Substitute E(s): e_ss = limₛ→₀ 1/[1 + G(s)].
6. Define the position error constant K_p = limₛ→₀ G(s).
7. Therefore, e_ss = 1/(1 + K_p).
Final Result
e_ss = 1/(1 + K_p)
Position Error Constant
K_p = limₛ→₀ G(s)
System Type Behaviour
Type 0: finite nonzero steady-state error for finite positive K_p.
Type 1 or higher: zero steady-state error for a step input, under stable unity-feedback conditions.
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
e_ss | Steady-state tracking error for a unit-step input | Same unit as the reference signal |
K_p | Position error constant | Dimensionless for a unity-scaled position loop |
G(s) | Open-loop forward-path transfer function for unity feedback | Depends on system scaling |
R(s) | Reference-input Laplace transform | Reference unit × s |
E(s) | Error-signal Laplace transform | Error unit × s |
SI units and conversions
Steady State Error
Same unit as the reference input
Position Error Constant
Dimensionless for unity-scaled systems
Dimensional Formula
Depends on the reference signal
Conditions of use
The system must use unity negative feedback.
The reference input must be a unit step for the stated expression.
The position error constant must exist or have a meaningful limiting value.
The closed-loop error response must satisfy the final-value theorem conditions.
The system type must be identified when interpreting finite or zero error.
Limitations and assumptions
The formula is not directly applicable to non-unity feedback without accounting for the feedback transfer function and signal scaling.
An unstable closed-loop system may not have a finite steady-state error.
A finite K_p produces a nonzero step error in a conventional Type 0 system.
The formula assumes a linear time-invariant model.
Actuator saturation, nonlinear friction, dead zones, and other nonlinearities can alter practical tracking error.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A stable unity-feedback system has a position error constant K_p = 9. Calculate its steady-state error for a unit-step input. |
| The steady-state error is 0.1, or 10% of the unit-step reference. |
A stable unity-feedback Type 0 system has G(s) = 20/(s + 4). Determine its unit-step steady-state error. |
| The steady-state error is approximately 0.1667, or 16.67% of the unit-step reference. |
Real-world applications
Position-control accuracy analysis
Motor-speed tracking
Servo-system design
Industrial setpoint regulation
Feedback-controller performance evaluation
Formula Meaning
For a stable unity-feedback system with a unit-step reference input, the steady-state error is the reciprocal of one plus the position error constant K_p, provided the final-value theorem conditions are satisfied.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.