For a stable unity-feedback system subjected to a unit-ramp reference input, the steady-state error is the reciprocal of the velocity error constant K_v, provided the final-value theorem conditions are satisfied.
Steady-State Error for Ramp Input
For a stable unity-feedback system subjected to a unit-ramp reference input, the steady-state error is the reciprocal of the velocity error constant K_v, provided the final-value theorem conditions are satisfied.
\(e_{\mathrm{ss}} = 1/K_{\mathrm{v}}\)
What this formula means
Scientific principle
Principle
A ramp input increases linearly with time. The velocity error constant measures the system's ability to track this continuously increasing reference. A larger velocity error constant generally produces a smaller steady-state ramp-tracking error.
Derivation
1. For a unity-feedback system, E(s) = R(s)/[1 + G(s)].
2. A unit-ramp input r(t) = t has Laplace transform R(s) = 1/s².
3. Therefore, E(s) = 1/[s²(1 + G(s))].
4. Apply the final-value theorem: e_ss = limₛ→₀ sE(s), provided the error response satisfies the theorem's stability conditions.
5. Substitute the error transform: e_ss = limₛ→₀ 1/[s(1 + G(s))].
6. Define the velocity error constant K_v = limₛ→₀ sG(s).
7. For the usual stable tracking case, the resulting steady-state error is e_ss = 1/K_v.
Final Result
e_ss = 1/K_v
Velocity Error Constant
K_v = limₛ→₀ sG(s)
System Type Behaviour
Type 0: infinite steady-state error for a unit ramp.
Type 1: finite steady-state error equal to 1/K_v.
Type 2 or higher: zero steady-state error for a unit ramp, under stable unity-feedback conditions.
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
e_ss | Steady-state tracking error for a unit-ramp input | Same unit as the reference signal |
K_v | Velocity error constant | s⁻¹ for a dimensionless position-loop gain convention |
G(s) | Open-loop forward-path transfer function for unity feedback | Depends on system scaling |
R(s) | Reference-input Laplace transform | Reference unit × s |
E(s) | Error-signal Laplace transform | Error unit × s |
t | Time | s |
SI units and conversions
Steady State Error
Same unit as the reference signal
Velocity Error Constant
s⁻¹ under the standard unity position-loop convention
Dimensional Formula
Depends on the reference signal and system scaling
Conditions of use
The system must use unity negative feedback.
The input must be a unit ramp, r(t) = t.
The velocity error constant must exist and be positive for a finite positive error.
The closed-loop error response must satisfy the final-value theorem conditions.
The system type must be determined before interpreting the result.
Limitations and assumptions
The equation is for a unit-ramp input; a ramp with slope A has steady-state error A/K_v.
A Type 0 system has unbounded ramp-tracking error under the conventional linear model.
The formula assumes a stable linear time-invariant system.
Non-unity feedback requires a modified error expression.
Real systems may have actuator limits and nonlinearities that prevent ideal ramp tracking.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A stable unity-feedback Type 1 system has K_v = 5 s⁻¹. Calculate its steady-state error for a unit-ramp input. |
| The steady-state error is 0.2 reference units. |
A unity-feedback system has G(s) = 10/[s(s + 2)]. Determine its steady-state error for a unit-ramp input. |
| The steady-state error is 0.2 reference units. |
Real-world applications
Constant-velocity position tracking
Robotic trajectory control
Servo and tracking systems
Machine-tool motion control
Control-system accuracy analysis
Formula Meaning
For a stable unity-feedback system subjected to a unit-ramp reference input, the steady-state error is the reciprocal of the velocity error constant K_v, provided the final-value theorem conditions are satisfied.