Steady-State Error for Parabolic Input

For a stable unity-feedback system subjected to a unit-parabolic reference input, the steady-state error is the reciprocal of the acceleration error constant K_a, provided the final-value theorem conditions are satisfied.

\(e_{\mathrm{ss}} = 1/K_{\mathrm{a}}\)

What this formula means

For a stable unity-feedback system subjected to a unit-parabolic reference input, the steady-state error is the reciprocal of the acceleration error constant K_a, provided the final-value theorem conditions are satisfied.

Scientific principle

Principle

A parabolic reference input has a linearly increasing rate of change and represents a constant-acceleration command. The acceleration error constant measures the ability of a feedback system to track this type of reference.

Derivation

  • 1. For unity negative feedback, E(s) = R(s)/[1 + G(s)].

  • 2. A unit-parabolic input r(t) = t²/2 has Laplace transform R(s) = 1/s³.

  • 3. Therefore, E(s) = 1/[s³(1 + G(s))].

  • 4. Apply the final-value theorem: e_ss = limₛ→₀ sE(s), provided the error response satisfies the theorem's stability conditions.

  • 5. Substitute E(s): e_ss = limₛ→₀ 1/[s²(1 + G(s))].

  • 6. Define the acceleration error constant K_a = limₛ→₀ s²G(s).

  • 7. For the usual stable tracking case, the steady-state error becomes e_ss = 1/K_a.

Final Result

e_ss = 1/K_a

Acceleration Error Constant

K_a = limₛ→₀ s²G(s)

System Type Behaviour

  • Type 0: infinite steady-state error for a unit-parabolic input.

  • Type 1: infinite steady-state error for a unit-parabolic input.

  • Type 2: finite steady-state error equal to 1/K_a.

  • Type 3 or higher: zero steady-state error for a unit-parabolic input, under stable unity-feedback conditions.

Variables and their meanings

SymbolMeaningUnit

e_ss

Steady-state tracking error for a unit-parabolic input

Same unit as the reference signal

K_a

Acceleration error constant

s⁻² under the standard unity position-loop convention

G(s)

Open-loop forward-path transfer function for unity feedback

Depends on system scaling

R(s)

Reference-input Laplace transform

Reference unit × s

E(s)

Error-signal Laplace transform

Error unit × s

t

Time

s

SI units and conversions

Steady State Error

Same unit as the reference signal

Acceleration Error Constant

s⁻² under the standard unity position-loop convention

Dimensional Formula

Depends on the reference signal and system scaling

Conditions of use

  • The system must use unity negative feedback.

  • The reference must be a unit-parabolic input r(t) = t²/2.

  • The acceleration error constant must exist and be positive for a finite positive error.

  • The closed-loop error response must satisfy the final-value theorem conditions.

  • The system must be Type 2 or higher for a finite steady-state error to a unit-parabolic input.

Limitations and assumptions

  • The equation is for a unit-parabolic input; a scaled parabolic input A t²/2 has steady-state error A/K_a.

  • Type 0 and Type 1 systems have unbounded parabolic tracking error under the conventional linear model.

  • The formula assumes a stable linear time-invariant system.

  • Non-unity feedback requires a modified error expression.

  • Practical acceleration limits, actuator saturation, friction, and nonlinearities can prevent ideal parabolic tracking.

Step-by-step worked examples

ProblemSolutionAnswer

A stable unity-feedback Type 2 system has K_a = 4 s⁻². Calculate its steady-state error for a unit-parabolic input.

  • Given: K_a = 4 s⁻².

  • Use: e_ss = 1/K_a.

  • e_ss = 1/4.

  • e_ss = 0.25.

The steady-state error is 0.25 reference units.

A unity-feedback system has G(s) = 12/[s²(s + 3)]. Determine its steady-state error for a unit-parabolic input.

  • Calculate the acceleration error constant: K_a = limₛ→₀ s²G(s).

  • K_a = limₛ→₀ 12/(s + 3).

  • K_a = 12/3 = 4 s⁻².

  • Use: e_ss = 1/K_a.

  • e_ss = 1/4 = 0.25.

The steady-state error is 0.25 reference units.

Real-world applications

  • Accelerating-motion tracking systems

  • Robotic trajectory control

  • Aerospace guidance and control

  • Precision motion-control systems

  • Control-system tracking-performance analysis

Formula Meaning

For a stable unity-feedback system subjected to a unit-parabolic reference input, the steady-state error is the reciprocal of the acceleration error constant K_a, provided the final-value theorem conditions are satisfied.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source