✦ScienexySCIENCE KNOWLEDGE LIBRARY
General science · SCI-FORM-ENG-1796

Richter Local Magnitude

Local magnitude is calculated from the logarithm of a measured seismic-wave amplitude corrected by a distance-dependent reference amplitude. It was originally developed for local earthquakes in southern California.

\(M_{\mathrm{L}} = log_{10}(A) - log_{10}(A_{0}(\Delta))\)

What this formula means

Local magnitude is calculated from the logarithm of a measured seismic-wave amplitude corrected by a distance-dependent reference amplitude. It was originally developed for local earthquakes in southern California.

Scientific principle

Principle

Seismic-wave amplitude generally decreases with distance from an earthquake because of geometrical spreading and energy attenuation. Local magnitude corrects measured amplitude using a calibrated reference function for the source-to-station distance.

Derivation

  • 1. Let A be the maximum recorded seismic-wave amplitude on the specified calibrated instrument.

  • 2. Let A₀(Δ) be the reference amplitude associated with epicentral distance Δ for a standard reference earthquake.

  • 3. The amplitude ratio A/A₀(Δ) compares the recorded signal with the reference signal.

  • 4. Local magnitude is defined as the base-10 logarithm of this amplitude ratio.

  • 5. Using logarithm rules gives M_L = log₁₀(A) − log₁₀(A₀(Δ)).

Final Result

M_L = log₁₀[A/A₀(Δ)]

Note

The original Richter scale used a standardized Wood-Anderson torsion seismograph and a regionally calibrated distance correction.

Variables and their meanings

SymbolMeaningUnit

M_L

Local earthquake magnitude

Dimensionless magnitude

A

Measured maximum seismic-wave amplitude using the specified calibration

Instrument-dependent amplitude unit

A₀(Δ)

Reference amplitude at epicentral distance Δ

Same unit as A

Δ

Epicentral distance between earthquake epicentre and recording station

km in the applicable calibration

SI units and conversions

Local Magnitude

Dimensionless

Amplitude Ratio

Dimensionless

Distance

km for the corresponding regional calibration

Dimensional Formula

Magnitude: dimensionless

Conditions of use

  • The amplitude must be measured using the specified instrument response or an appropriate equivalent calibration.

  • The reference function A₀(Δ) must match the applicable regional magnitude scale.

  • The recorded amplitude and reference amplitude must use the same amplitude units.

  • The original Richter relation is intended for local earthquakes within its calibration range.

  • The logarithm is base 10.

Limitations and assumptions

  • The original Richter scale was developed for a specific regional setting and instrument.

  • Local magnitude can saturate for large earthquakes and may underestimate their relative size.

  • Different regional networks may use different calibration functions.

  • Instrument response, attenuation, geology, and station conditions affect measured amplitude.

  • Local magnitude is not interchangeable with moment magnitude.

Step-by-step worked examples

ProblemSolutionAnswer

At a particular calibrated distance, a seismic station records an amplitude 100 times the reference amplitude. Calculate the local magnitude using the amplitude-ratio relation.

  • Given: A/A₀(Δ) = 100.

  • Use: M_L = log₁₀[A/A₀(Δ)].

  • M_L = log₁₀(100).

  • M_L = 2.

The local magnitude under the stated calibration is 2.

A calibrated seismic record has an amplitude ratio A/A₀(Δ) = 1,000. Calculate its local magnitude.

  • Given: A/A₀(Δ) = 1,000.

  • M_L = log₁₀(1,000).

  • M_L = 3.

The local magnitude under the stated calibration is 3.

Real-world applications

  • Local earthquake monitoring

  • Regional seismic network analysis

  • Historical earthquake magnitude comparison

  • Seismic station data interpretation

  • Earthquake catalogue preparation

Formula Meaning

Local magnitude is calculated from the logarithm of a measured seismic-wave amplitude corrected by a distance-dependent reference amplitude. It was originally developed for local earthquakes in southern California.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source