✦ScienexySCIENCE KNOWLEDGE LIBRARY
General science · SCI-FORM-FLU-007

Poiseuille Flow Rate

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

\(Q = \pi r^{4}\Delta P/(8\mu L)\)

What this formula means

Definition

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

Interpretation

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

Physical Significance

Hagen–Poiseuille law.

Scientific principle

Principle

Hagen–Poiseuille law

Derivation

StepExplanationExpression

1

Identify the physical quantities and the governing definition or conservation principle.

Q = πr⁴ΔP/(8μL)

2

Apply the stated ideal-model assumptions and express the quantities in consistent SI units.

Q = πr⁴ΔP/(8μL)

3

Rearrange the governing relation for the required quantity and check its dimensions.

Q = πr⁴ΔP/(8μL)

Result

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

Variables and their meanings

SymbolMeaningDescription

Q

Volume flow rate

Volume flow rate.

r

Tube inner radius

Tube inner radius.

ΔP

Pressure difference across the tube

Pressure difference across the tube.

μ

Dynamic viscosity

Dynamic viscosity.

L

Tube length

Tube length.

SI units and conversions

Si Unit

cubic metre per second (m³/s)

Dimensional Formula

[L³ T⁻¹]

Unit Explanation

The result is expressed in cubic metre per second (m³/s); the dimensional formula is [L³ T⁻¹].

Unit Conversions

No items supplied.

Conditions of use

  • Flow is steady, laminar and fully developed.

  • The tube is straight, circular, rigid and of constant radius.

  • The fluid is incompressible and Newtonian, with no-slip at the wall.

Limitations and assumptions

  • The r⁴ dependence makes small radius changes highly significant.

  • The relation is unsuitable for turbulent flow or strongly non-Newtonian fluids.

Step-by-step worked examples

ProblemGivenSolutionAnswer

For a tube, r = 1.0×10⁻³ m, ΔP = 200 Pa, μ = 1.0×10⁻³ Pa·s and L = 0.50 m. Find Q.

  • Use the values stated in the problem.

StepExplanationCalculation

1

Write the governing relation.

Q = πr⁴ΔP/(8μL)

2

Substitute the given values using consistent SI units.

Q = π(1.0×10⁻³)⁴(200)/[8(1.0×10⁻³)(0.50)] ≈ 1.57×10⁻⁷ m³/s

The volume flow rate is approximately 1.57×10⁻⁷ m³/s.

Real-world applications

ApplicationExplanation

Microfluidic channel design

This relation supports quantitative analysis and design in microfluidic channel design.

Laminar flow in capillaries

This relation supports quantitative analysis and design in laminar flow in capillaries.

Modelling flow through small tubes

This relation supports quantitative analysis and design in modelling flow through small tubes.

Formula Meaning

Definition

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

Interpretation

For steady laminar flow of a Newtonian fluid through a long circular tube, the volume flow rate is proportional to the pressure difference and the fourth power of tube radius.

Physical Significance

Hagen–Poiseuille law.

Sources and further reading

No source has been supplied for this item yet. Treat the claim as needing editorial verification.

← Back to Formula Hub · Suggest a correction or source