When a measured quantity is raised to a fixed power, its relative standard uncertainty is approximately the magnitude of the exponent multiplied by the relative standard uncertainty of the original quantity. The relation follows from first-order uncertainty propagation.
Propagation of Uncertainty for a Power
When a measured quantity is raised to a fixed power, its relative standard uncertainty is approximately the magnitude of the exponent multiplied by the relative standard uncertainty of the original quantity. The relation follows from first-order uncertainty propagation.
\(\text{ for } y = x^{n}: u_{\mathrm{c}}(y)/|y| \approx |n|u(x)/|x|\)
What this formula means
Scientific principle
Principle
A power transformation changes the sensitivity of a calculated result to uncertainty in its input. The derivative of xⁿ is nxⁿ⁻¹, so the uncertainty contribution is proportional to the exponent n.
Derivation
1. Let y = xⁿ, where n is a fixed exponent.
2. Differentiate: dy/dx = nxⁿ⁻¹.
3. The first-order standard uncertainty is u_c(y) ≈ |dy/dx|u(x).
4. Therefore, u_c(y) ≈ |n xⁿ⁻¹|u(x).
5. Since |y| = |x|ⁿ for positive integer or real powers in the valid domain, divide by |y|.
6. Simplifying gives u_c(y)/|y| ≈ |n|u(x)/|x|.
Final Result
u_c(y) ≈ |n xⁿ⁻¹|u(x)
Relative Uncertainty
u_c(y)/|y| ≈ |n|u(x)/|x|
Percentage Relation
Percentage uncertainty in y ≈ |n| × percentage uncertainty in x
Variables and their meanings
| Symbol | Meaning | Unit |
|---|---|---|
y | Calculated power of the measured quantity | Unit of x raised to power n |
x | Measured input quantity | Physical unit of the input |
n | Fixed exponent | Dimensionless |
u(x) | Standard uncertainty of x | Same unit as x |
u_c(y) | Combined standard uncertainty of y | Same unit as y |
SI units and conversions
Relative Uncertainty
Dimensionless
Absolute Uncertainty
Same unit as y
Exponent
Dimensionless
Output Quantity
Input unit raised to the power n
Conditions of use
The input quantity is nonzero for the relative uncertainty expression.
The exponent is treated as an exact constant.
The input uncertainty is sufficiently small for first-order propagation.
The input uncertainty is represented by a standard uncertainty.
The mathematical domain of xⁿ must be valid for the measured value and its uncertainty range.
Limitations and assumptions
The formula is a first-order approximation.
It does not directly account for uncertainty in the exponent.
For large uncertainties, nonlinear effects may make the approximation inaccurate.
For negative or fractional powers, the input domain must be checked.
When n = 0, y is constant and the propagated uncertainty is zero under the stated model.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A measured radius is 5.0 cm with standard uncertainty 0.1 cm. Calculate the relative standard uncertainty in the circular area A = πr². |
| The relative standard uncertainty is approximately 4%, and the area uncertainty is approximately 3.14 cm². |
A measured length is 2.00 m with relative standard uncertainty 1.5%. A calculated quantity is proportional to the cube of this length. Determine the relative uncertainty of the calculated quantity. |
| The relative standard uncertainty in the calculated quantity is approximately 4.5%. |
Real-world applications
Area and volume uncertainty calculations
Geometrical measurements
Power-law physical relationships
Uncertainty analysis in mechanics
Scientific model parameter estimation
Formula Meaning
When a measured quantity is raised to a fixed power, its relative standard uncertainty is approximately the magnitude of the exponent multiplied by the relative standard uncertainty of the original quantity. The relation follows from first-order uncertainty propagation.
Sources and further reading