Steady-state drug concentration is the theoretical concentration approached during constant drug input when the average rate of drug administration equals the rate of elimination. In the ideal constant-infusion model, it is determined by input rate and clearance.
Steady-State Drug Concentration
Steady-state drug concentration is the theoretical concentration approached during constant drug input when the average rate of drug administration equals the rate of elimination. In the ideal constant-infusion model, it is determined by input rate and clearance.
\(C_{ss} = R_{0}/CL\)
What this formula means
Scientific principle
Principle
During constant infusion, drug concentration increases as the drug enters systemic circulation. Elimination also increases with concentration. At steady state, input and elimination become equal.
Derivation
The rate of change of drug amount is dA/dt = R₀ − CL × C.
At steady state, the amount does not change with time.
Therefore, dA/dt = 0.
Substitute into the rate equation: 0 = R₀ − CL × Cₛₛ.
Rearranging gives CL × Cₛₛ = R₀.
Therefore, Cₛₛ = R₀/CL.
Final Result
Cₛₛ = R₀/CL for constant infusion under linear pharmacokinetic conditions.
Variables and their meanings
Css
Steady-state plasma drug concentration.
R0
Constant drug input rate.
CL
Total body drug clearance.
SI units and conversions
Css
mg·L⁻¹.
R0
mg·h⁻¹.
CL
L·h⁻¹.
Dimensional Formula Of Concentration
M L⁻³, where M represents amount of substance.
Conditions of use
Drug input must remain constant.
Clearance must be approximately constant.
Elimination must follow linear pharmacokinetics.
The system must have reached steady state.
Input and elimination must be expressed using compatible units.
Limitations and assumptions
The equation does not describe the time required to reach steady state.
Nonlinear elimination can invalidate the simple proportional relationship.
Changing clearance changes the theoretical steady-state concentration.
Multicompartment distribution can affect the concentration-time profile before steady state.
A calculated steady-state concentration does not establish therapeutic suitability.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A theoretical pharmacokinetic system has a constant input rate of 24 mg·h⁻¹ and clearance of 6 L·h⁻¹. Determine its steady-state concentration. |
| The theoretical steady-state concentration is 4 mg·L⁻¹. |
A theoretical model has a steady-state concentration of 3 mg·L⁻¹ and clearance of 8 L·h⁻¹. Determine the corresponding input rate represented by the model. |
| The corresponding theoretical input rate is 24 mg·h⁻¹. |
Real-world applications
Understanding continuous drug administration.
Studying drug input and elimination balance.
Analyzing pharmacokinetic steady states.
Investigating changes in drug clearance.
Interpreting concentration-time models.
Formula Meaning
Steady-state drug concentration is the theoretical concentration approached during constant drug input when the average rate of drug administration equals the rate of elimination. In the ideal constant-infusion model, it is determined by input rate and clearance.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.