Systemic vascular resistance is the resistance opposing blood flow through the systemic circulation. It is estimated from the pressure difference between the systemic arterial and central venous sides divided by cardiac output.
Systemic Vascular Resistance
Systemic vascular resistance is the resistance opposing blood flow through the systemic circulation. It is estimated from the pressure difference between the systemic arterial and central venous sides divided by cardiac output.
\(SVR = (MAP - CVP)/CO; SVR in \mathrm{dyn}\cdot\mathrm{s}\cdot\mathrm{cm}^{-5} = 80 \times (MAP - CVP)/CO\)
What this formula means
Scientific principle
Principle
Blood flows through the systemic circulation because of a pressure gradient. For a given flow, a larger pressure difference corresponds to greater vascular resistance. The relationship is analogous to the general flow-resistance relationship used in fluid mechanics.
Derivation
Let MAP represent mean systemic arterial pressure.
Let CVP represent central venous pressure.
The systemic pressure gradient is MAP − CVP.
Let CO represent cardiac output.
Resistance is pressure difference divided by flow.
Therefore, SVR = (MAP − CVP)/CO.
When pressure is in mmHg and flow is in L·min⁻¹, the result is in Wood units.
One Wood unit equals 80 dyn·s·cm⁻⁵.
Therefore, SVR in dyn·s·cm⁻⁵ = 80 × (MAP − CVP)/CO.
Final Result
SVR = (MAP − CVP)/CO in Wood units, or 80 × (MAP − CVP)/CO in dyn·s·cm⁻⁵.
Variables and their meanings
SVR
Systemic vascular resistance.
MAP
Mean systemic arterial pressure.
CVP
Central venous pressure.
CO
Cardiac output.
Wood Unit
A pressure-flow resistance unit equal to mmHg·min·L⁻¹.
SI units and conversions
Pressure
mmHg.
Cardiac Output
L·min⁻¹.
Resistance Wood Units
Wood units, equivalent to mmHg·min·L⁻¹.
Resistance CGS
dyn·s·cm⁻⁵.
Conversion
1 Wood unit = 80 dyn·s·cm⁻⁵.
Conditions of use
MAP and CVP must be expressed in the same pressure units.
Cardiac output must be expressed in L·min⁻¹ for the stated conversion.
The pressure difference must represent the systemic circulation.
The result assumes a meaningful average pressure-flow relationship.
Limitations and assumptions
SVR is a calculated global resistance and does not represent the resistance of every individual vessel.
Vascular resistance changes with vessel diameter, vascular tone and physiological conditions.
Errors in cardiac output, MAP or CVP measurements affect the calculated result.
The simplified relationship does not describe pulsatile flow or the full complexity of vascular compliance.
Systemic vascular resistance must not be confused with pulmonary vascular resistance.
Step-by-step worked examples
| Problem | Solution | Answer |
|---|---|---|
A theoretical hemodynamic model has MAP = 90 mmHg, CVP = 5 mmHg and cardiac output = 5 L·min⁻¹. Calculate systemic vascular resistance in Wood units and dyn·s·cm⁻⁵. |
| SVR = 17 Wood units = 1360 dyn·s·cm⁻⁵. |
A theoretical model has MAP = 100 mmHg, CVP = 10 mmHg and cardiac output = 6 L·min⁻¹. Calculate SVR. |
| SVR = 15 Wood units or 1200 dyn·s·cm⁻⁵. |
Real-world applications
Studying systemic circulation and vascular tone.
Analyzing pressure-flow relationships.
Understanding the influence of vascular resistance on cardiac workload.
Interpreting hemodynamic measurements.
Comparing systemic and pulmonary circulation.
Formula Meaning
Systemic vascular resistance is the resistance opposing blood flow through the systemic circulation. It is estimated from the pressure difference between the systemic arterial and central venous sides divided by cardiac output.
Sources and further reading
No source has been supplied for this item yet. Treat the claim as needing editorial verification.