Sound intensity level is a logarithmic measure that compares a measured sound intensity with a reference intensity. It is expressed in decibels (dB). For sound in air, the commonly used reference intensity is I₀ = 10⁻¹² W/m², corresponding approximately to the conventional reference near the threshold of hearing under specified conditions. The logarithmic scale is useful because acoustic intensities can span a very large range. A tenfold increase in intensity produces an increase of 10 dB, while a hundredfold increase produces an increase of 20 dB. Sound intensity level is not the same as sound pressure level, although the two are closely related for a plane progressive wave under suitable conditions. The reference value and measurement conditions should always be stated when interpreting a level.
Sound Intensity Level
Sound intensity level expresses sound intensity logarithmically relative to a specified reference intensity.
L_I = 10 log₁₀(I/I₀)
Explanation
Variables
| Symbol | Meaning |
|---|---|
L_I | Sound intensity level, measured in decibels (dB). |
I | Measured sound intensity, measured in watts per square metre (W/m²). |
I₀ | Reference sound intensity; commonly 10⁻¹² W/m² in air. |
Example or application
If sound intensity is 10⁻⁶ W/m² and the reference intensity is 10⁻¹² W/m², then L_I = 10 log₁₀(10⁻⁶/10⁻¹²) = 10 log₁₀(10⁶) = 60 dB.
Key Points
Sound intensity level uses a logarithmic scale.
It compares measured intensity with a reference intensity.
The level is expressed in decibels.
A tenfold intensity increase corresponds to a 10 dB increase.
Intensity level and pressure level use different defining quantities and reference values.
Applications
Comparing environmental sound intensity levels.
Describing acoustic measurement results.
Evaluating noise-control systems.
Communicating large intensity ratios using a manageable scale.
Common Mistakes
Using 20 log instead of 10 log for an intensity ratio.
Confusing sound intensity level with sound pressure level.
Ignoring the reference intensity.
Treating a decibel value as a linear measurement.
Learning Outcomes
Define sound intensity level.
Explain why a logarithmic scale is useful.
Calculate intensity level from intensity and reference intensity.
Interpret changes in intensity in decibels.
Practice Questions
| Question | Answer |
|---|---|
What is the commonly used reference intensity for sound in air? | I₀ = 10⁻¹² W/m². |
How many decibels above the reference is an intensity 100 times larger than I₀? | L_I = 10 log₁₀(100) = 20 dB. |
What happens to intensity level when intensity increases by a factor of 10? | The intensity level increases by 10 dB. |
Related Concepts
Sound Intensity
Decibel Scale
Sound Pressure Level
Noise Measurement and Monitoring
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Fundamentals of Acoustics by Lawrence E. Kinsler et al.; IEC 61672-1, Electroacoustics: Sound Level Meters.