✦ScienexySCIENCE KNOWLEDGE LIBRARY
Science reference · INFO-PHY-ACOU-021

Sound Intensity Level

Sound intensity level expresses sound intensity logarithmically relative to a specified reference intensity.

L_I = 10 log₁₀(I/I₀)

Explanation

Sound intensity level is a logarithmic measure that compares a measured sound intensity with a reference intensity. It is expressed in decibels (dB). For sound in air, the commonly used reference intensity is I₀ = 10⁻¹² W/m², corresponding approximately to the conventional reference near the threshold of hearing under specified conditions. The logarithmic scale is useful because acoustic intensities can span a very large range. A tenfold increase in intensity produces an increase of 10 dB, while a hundredfold increase produces an increase of 20 dB. Sound intensity level is not the same as sound pressure level, although the two are closely related for a plane progressive wave under suitable conditions. The reference value and measurement conditions should always be stated when interpreting a level.

Variables

SymbolMeaning

L_I

Sound intensity level, measured in decibels (dB).

I

Measured sound intensity, measured in watts per square metre (W/m²).

I₀

Reference sound intensity; commonly 10⁻¹² W/m² in air.

Example or application

If sound intensity is 10⁻⁶ W/m² and the reference intensity is 10⁻¹² W/m², then L_I = 10 log₁₀(10⁻⁶/10⁻¹²) = 10 log₁₀(10⁶) = 60 dB.

Key Points

  • Sound intensity level uses a logarithmic scale.

  • It compares measured intensity with a reference intensity.

  • The level is expressed in decibels.

  • A tenfold intensity increase corresponds to a 10 dB increase.

  • Intensity level and pressure level use different defining quantities and reference values.

Applications

  • Comparing environmental sound intensity levels.

  • Describing acoustic measurement results.

  • Evaluating noise-control systems.

  • Communicating large intensity ratios using a manageable scale.

Common Mistakes

  • Using 20 log instead of 10 log for an intensity ratio.

  • Confusing sound intensity level with sound pressure level.

  • Ignoring the reference intensity.

  • Treating a decibel value as a linear measurement.

Learning Outcomes

  • Define sound intensity level.

  • Explain why a logarithmic scale is useful.

  • Calculate intensity level from intensity and reference intensity.

  • Interpret changes in intensity in decibels.

Practice Questions

QuestionAnswer

What is the commonly used reference intensity for sound in air?

I₀ = 10⁻¹² W/m².

How many decibels above the reference is an intensity 100 times larger than I₀?

L_I = 10 log₁₀(100) = 20 dB.

What happens to intensity level when intensity increases by a factor of 10?

The intensity level increases by 10 dB.

Related Concepts

  • Sound Intensity

  • Decibel Scale

  • Sound Pressure Level

  • Noise Measurement and Monitoring

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Fundamentals of Acoustics by Lawrence E. Kinsler et al.; IEC 61672-1, Electroacoustics: Sound Level Meters.

Suggest a correction or source · More in Acoustics