✦ScienexySCIENCE KNOWLEDGE LIBRARY
Science reference · INFO-PHY-ACOU-023

Sound Pressure and Sound Pressure Level

Sound pressure is the fluctuating pressure caused by a sound wave, while sound pressure level expresses its RMS value logarithmically relative to a reference pressure.

L_p = 20 log₁₀(p_rms/p₀)

Explanation

Sound pressure is the difference between instantaneous total pressure in a sound field and the equilibrium pressure that would exist without the sound disturbance. It is measured in pascals (Pa). Because acoustic pressure fluctuates with time, measurements commonly use the root-mean-square (RMS) value over a specified time interval. Sound pressure level (SPL) expresses this RMS pressure relative to a reference pressure using a logarithmic scale. In air, the standard reference sound pressure is p₀ = 20 μPa. The reference is different in some other media and measurement contexts. SPL is expressed in decibels (dB). It is a pressure-based level and should not be confused with sound intensity level, which is defined using acoustic intensity. For a plane progressive wave in a specified medium, the two levels are closely related through the characteristic impedance.

Variables

SymbolMeaning

L_p

Sound pressure level, measured in decibels (dB).

p_rms

Root-mean-square sound pressure, measured in pascals (Pa).

p₀

Reference sound pressure; commonly 20 μPa in air.

Example or application

A sound field has an RMS pressure of 0.02 Pa in air. Using p₀ = 20 μPa = 0.00002 Pa, its SPL is 20 log₁₀(0.02/0.00002) = 20 log₁₀(1000) = 60 dB SPL.

Key Points

  • Sound pressure is a local acoustic pressure variation.

  • Sound pressure is measured in pascals.

  • SPL uses RMS sound pressure for the stated measurement interval.

  • The reference pressure in air is commonly 20 μPa.

  • SPL is expressed in decibels.

  • SPL and intensity level are distinct quantities.

Applications

  • Measuring environmental noise.

  • Testing loudspeakers and headphones.

  • Assessing room acoustics.

  • Calibrating sound-level meters.

  • Monitoring sound exposure in workplaces.

Common Mistakes

  • Using peak pressure instead of RMS pressure without converting appropriately.

  • Using 10 log for a sound-pressure ratio.

  • Confusing pascals with decibels.

  • Using the air reference pressure without considering the measurement medium and standard.

  • Treating SPL as exactly equivalent to intensity level in every acoustic field.

Learning Outcomes

  • Define sound pressure.

  • Explain the role of RMS pressure in SPL measurements.

  • Calculate SPL using the correct reference pressure.

  • Distinguish sound pressure level from sound intensity level.

Practice Questions

QuestionAnswer

What is sound pressure?

It is the pressure variation associated with a sound wave relative to the equilibrium pressure.

What is the commonly used reference sound pressure in air?

20 μPa.

An RMS sound pressure is 0.002 Pa. Find its SPL in air using p₀ = 20 μPa.

L_p = 20 log₁₀(0.002/0.00002) = 20 log₁₀(100) = 40 dB SPL.

Related Concepts

  • Sound Intensity

  • Sound Intensity Level

  • Decibel Scale

  • Acoustic Impedance

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • IEC 61672-1, Electroacoustics: Sound Level Meters; Fundamentals of Acoustics by Lawrence E. Kinsler et al.

Suggest a correction or source · More in Acoustics