✦ScienexySCIENCE KNOWLEDGE LIBRARY
Science reference · INFO-PHY-ACOU-069

Eyring's Reverberation Formula

Eyring's formula estimates reverberation time by accounting for repeated sound reflections and average surface absorption.

RT₆₀ = 0.161V/[−S ln(1 − ᾱ)]

Explanation

Eyring's formula is used to estimate reverberation time in rooms with a diffuse sound field and approximately uniform average surface absorption. It accounts for the cumulative reduction of sound energy at repeated reflections using a logarithmic term. Here, S is the total room boundary surface area and ᾱ is the average sound absorption coefficient. For low average absorption, the logarithmic expression can be approximated by ᾱ, making Eyring's result approach Sabine's formula when A = Sᾱ. Eyring's model can be more appropriate than Sabine's formula for rooms with higher average absorption, although its assumptions about the sound field and absorption distribution still matter.

Variables

SymbolMeaningUnit

RT₆₀

Reverberation time

s

V

Room volume

m³

S

Total area of room boundaries

m²

ᾱ

Average sound absorption coefficient

Dimensionless

ln

Natural logarithm

Dimensionless

Example or application

For a room with V = 150 m³, S = 200 m² and average absorption coefficient 0.20, Eyring's formula gives RT60 ≈ 0.161 × 150/[−200 ln(0.80)] ≈ 0.542 s.

Key Points

  • Eyring's formula includes a logarithmic absorption term.

  • It uses room volume, total boundary area and average absorption coefficient.

  • It can improve estimates for rooms with higher average absorption.

  • For low absorption, it approaches Sabine's result.

  • It still assumes a sufficiently diffuse sound field and reasonably uniform absorption.

Applications

  • Room acoustic design

  • Auditorium reverberation prediction

  • Acoustic treatment evaluation

  • Comparison of room reverberation models

Common Mistakes

  • Using the natural logarithm as a base-10 logarithm.

  • Using total absorption area in place of S without adjusting the formula.

  • Assuming Eyring's formula removes all limitations of diffuse-field models.

Learning Outcomes

  • State Eyring's reverberation formula.

  • Identify the quantities used in the formula.

  • Explain its relationship to Sabine's formula.

  • Recognize when Eyring's model may be useful.

Practice Questions

QuestionAnswer

What additional room quantity appears explicitly in Eyring's formula?

The total boundary surface area and average absorption coefficient.

Which logarithm is used in Eyring's formula?

The natural logarithm.

How does Eyring's formula relate to Sabine's formula at low absorption?

It approaches Sabine's result.

Related Concepts

  • Sabine's Formula

  • Reverberation Time

  • Sound Absorption Coefficient

  • Room Acoustic Design

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Architectural Acoustics — Marshall Long
  • Fundamentals of Acoustics — Lawrence E. Kinsler et al.

Suggest a correction or source · More in Acoustics