✦ScienexySCIENCE KNOWLEDGE LIBRARY
Science reference · INFO-PHY-ACOU-132

Sound Transmission Loss

Sound transmission loss measures how effectively a building element reduces sound power passing through it.

TL = 10 log10(W_i/W_t)

Explanation

Sound transmission loss, also called transmission loss in many acoustic contexts, expresses the reduction in transmitted sound power through a partition. It is calculated as the ratio of incident sound power to transmitted sound power on a logarithmic decibel scale. A higher transmission-loss value indicates better sound isolation under the specified test conditions. Transmission loss varies with frequency and depends on surface mass, stiffness, damping, cavity construction, resonance and coincidence effects. Laboratory transmission-loss measurements are different from the apparent sound insulation measured between completed rooms, where flanking paths and building details also contribute.

Variables

SymbolMeaning

TL

Sound transmission loss, measured in decibels (dB).

W_i

Incident sound power on the partition, measured in watts (W).

W_t

Transmitted sound power through the partition, measured in watts (W).

Example or application

If a partition receives 10 W of incident acoustic power and transmits 0.01 W, its transmission loss is 30 dB under the idealized power-ratio definition.

Key Points

  • Transmission loss is expressed in decibels.

  • Higher transmission loss indicates less transmitted sound power.

  • Transmission loss varies with frequency.

  • Mass, stiffness and construction details influence performance.

  • Laboratory transmission loss does not fully describe field sound insulation.

Applications

  • Comparing wall and floor constructions.

  • Selecting windows and doors for noise control.

  • Designing sound-isolating partitions.

  • Evaluating building components in acoustic laboratories.

Common Mistakes

  • Assuming transmission loss is constant across all frequencies.

  • Confusing laboratory transmission loss with field sound reduction.

  • Assuming the decibel value is a direct percentage reduction.

Learning Outcomes

  • Define sound transmission loss.

  • Calculate transmission loss from incident and transmitted sound power.

  • Explain why transmission loss depends on frequency.

  • Distinguish transmission loss from field sound insulation ratings.

Practice Questions

QuestionAnswer

What does a higher transmission-loss value indicate?

A smaller proportion of incident sound power is transmitted through the partition.

What is the transmission loss if 10 W of sound power is incident and 0.01 W is transmitted?

30 dB.

Does laboratory transmission loss include every flanking path in a completed building?

No. Laboratory tests isolate the specimen more carefully than typical field conditions.

Related Concepts

  • Acoustic Insulation

  • Sound Reduction Index

  • Airborne Sound

  • Flanking Transmission

  • Noise Control

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Building Acoustics by Tor Erik Vigran; ASTM E90, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.

Suggest a correction or source · More in Acoustics