Impulsive noise is produced by brief events such as hammer strikes, metal impacts, explosions and some industrial operations. It is characterized by a rapid increase in sound pressure followed by a relatively short decay. Some impulsive events contain a single prominent peak, while others occur as repeated impulses. Peak sound pressure level and suitable time-weighted or event-based measurements may be needed to characterize these sounds. Impulsive noise can be important in occupational and environmental assessments because a short event may have a high peak level even when its contribution to a long-term average is limited.
Impulsive Noise
Impulsive noise consists of short-duration sound events that rise rapidly to a high level and may contain substantial acoustic energy over a brief period.
L_Cpeak = 20 log₁₀(p_Cpeak/p₀)
Explanation
Variables
| Symbol | Meaning |
|---|---|
L_Cpeak | C-weighted peak sound pressure level, measured in decibels (dB). |
p_Cpeak | Maximum absolute C-weighted instantaneous sound pressure under the applicable measurement convention, measured in pascals (Pa). |
p₀ | Reference sound pressure in air, equal to 20 μPa. |
Example or application
A metal sheet dropped onto a hard factory floor can produce a brief impulsive sound with a high peak level, even though the event lasts only a short time.
Key Points
Impulsive noise consists of short-duration sound events.
It often has a rapid rise and short decay.
Impulses may occur singly or repeatedly.
Peak measurements can be important for characterizing impulsive sound.
Long-term average levels alone may not describe every impulsive hazard.
Applications
Assessing industrial impact noise.
Monitoring construction and demolition activities.
Evaluating firearm and explosive impulse noise in controlled professional settings.
Testing machinery that produces repeated impacts.
Occupational noise-risk assessment.
Common Mistakes
Assuming a short sound event cannot create a significant exposure concern.
Using only an average sound level to describe a strong impulse.
Confusing intermittent noise with impulsive noise.
Ignoring the measurement time response and frequency weighting.
Learning Outcomes
Define impulsive noise.
Describe its typical time pattern.
Explain why peak sound pressure measurements may be needed.
Distinguish impulsive noise from continuous and intermittent noise.
Practice Questions
| Question | Answer |
|---|---|
What is impulsive noise? | A short-duration sound event that typically rises rapidly to a peak and then decays. |
Why can peak sound pressure level be useful for impulsive noise? | It captures the maximum pressure of a brief event that may be obscured by long-term averaging. |
Give one example of impulsive noise. | A hammer striking a metal surface. |
Related Concepts
Noise Classification
Peak Sound Pressure Level
Occupational Noise
Industrial Noise
Noise Measurement
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- ISO 1999, Acoustics—Estimation of Noise-Induced Hearing Loss; Engineering Noise Control by David A. Bies and Colin H. Hansen.