The decibel scale compresses a wide range of acoustic intensities into manageable numerical values. Sound intensity level is calculated using β = 10 log₁₀(I/I₀), where I₀ is the chosen reference intensity. Sound pressure level is calculated using Lₚ = 20 log₁₀(p_rms/p₀), where p_rms is the root-mean-square sound pressure and p₀ is the reference pressure. In air, the standard reference sound pressure is commonly 20 μPa. The factor of 20 in the pressure-level equation arises because intensity is proportional to the square of sound pressure for a progressive wave under the same medium conditions. A tenfold increase in intensity corresponds to an increase of 10 dB, while a tenfold increase in sound pressure corresponds to approximately 20 dB under those conditions. Decibel values must always be interpreted with their reference quantity and measurement conditions.
The Decibel Scale
The decibel is a logarithmic unit used to express a ratio of sound intensities or sound powers. For sound intensity level, the decibel value is ten times the base-10 logarithm of the intensity ratio relative to a reference intensity.
β = 10 log₁₀(I/I₀); Lₚ = 20 log₁₀(p_rms/p₀)
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
β | Sound intensity level | dB |
I | Measured sound intensity | W/m² |
I₀ | Reference sound intensity | W/m² |
Lₚ | Sound pressure level | dB |
p_rms | Root-mean-square sound pressure | Pa |
p₀ | Reference sound pressure, commonly 20 μPa in air | Pa |
Example or application
If the sound intensity is 100 times the reference intensity, the intensity level is 10 log₁₀(100) = 20 dB above the reference level.
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
Suggest a correction or source · More in Oscillations & Waves