A refrigerator transports heat from its cold region to its warmer surroundings by consuming work. Over a complete cycle, energy conservation gives Q_H = Q_C + W_in, where Q_C is the heat removed from the refrigerated space, Q_H is the heat rejected to the surroundings, and W_in is the work supplied. The refrigerator's coefficient of performance is COP_R = Q_C/W_in. Unlike thermal efficiency, COP is not a fraction of energy converted into work and can exceed one because the device moves heat rather than converting all input energy into a different form. For an ideal reversible refrigerator operating between fixed reservoir temperatures, COP_R,max = T_C/(T_H − T_C). All temperatures in this expression must be absolute temperatures in kelvin. A larger COP means that less work is required for a given amount of heat removal.
Refrigerators and Coefficient of Performance
A refrigerator uses external work to remove heat from a low-temperature space and discharge it to warmer surroundings. Its coefficient of performance (COP) measures heat removed per unit of work supplied.
COP_R = Q_C / W_in = Q_C / (Q_H − Q_C)
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
COP_R | Coefficient of performance of a refrigerator | Dimensionless |
Q_C | Heat removed from the cold space per cycle | J |
Q_H | Heat rejected to the warmer surroundings per cycle | J |
W_in | Work supplied to the refrigerator per cycle | J |
T_C | Cold-space absolute temperature | K |
T_H | Hot-surroundings absolute temperature | K |
Example or application
A refrigerator removes 600 J of heat while consuming 150 J of work. Its coefficient of performance is COP_R = 600/150 = 4. It rejects 750 J of heat to the surroundings.