No experimental measurement is completely free from error. In analytical chemistry, an error is the difference between a measured value and the true value or an accepted reference value of the measurand. Errors may arise during sampling, sample preparation, reagent preparation, calibration, measurement, calculation, or reporting.
Random errors produce unpredictable variation in repeated measurements. They may result from small uncontrolled changes in temperature, reading position, instrument noise, or other fluctuating conditions. Random errors mainly influence precision and can be studied using replicate measurements and statistical methods.
Systematic errors cause results to deviate in a consistent direction or according to a predictable pattern. They may arise from incorrect calibration, an impure reagent, a consistent volume-reading error, incomplete analyte recovery, or a method-related matrix effect. Systematic errors influence trueness and are not necessarily reduced by repeating the same measurement.
Gross errors are large mistakes caused by failures such as using the wrong reagent, recording an incorrect sample identity, misreading a scale, or making a major calculation error. Such events should be investigated and documented. A result should not be removed merely because it appears unusual.
Errors may also be classified according to their source. Instrumental errors arise from measurement equipment; personal errors arise from operator actions; method errors arise from limitations or assumptions in the procedure; and sampling errors arise when the collected portion does not represent the target material.
The distinction between error and uncertainty is important. Error is the difference between a measured value and a reference or true value. Measurement uncertainty describes the dispersion of values that could reasonably be attributed to the measurand. Since the true value is generally not known exactly, uncertainty is used to express the quality of the measurement result.
Error control requires appropriate sampling, calibration, blanks, reference materials, replicate measurements, instrument maintenance, validated procedures, and careful documentation.
Errors in Chemical Analysis
Errors in chemical analysis are differences between measured results and the corresponding true or reference values. They may arise from random variation, systematic effects, or gross mistakes. Understanding their sources and behaviour helps analysts improve measurement quality and interpret uncertainty.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
E | Absolute error | Same as measurand |
xmeasured | Measured value | Same as measurand |
xreference | Accepted reference value | Same as measurand |
xᵢ | Individual measurement | Same as measurand |
x̄ | Mean of replicate results | Same as measurand |
s | Sample standard deviation | Same as measurand |
n | Number of measurements | Dimensionless |
Example or application
A worked example has not yet been added.
Definition
An analytical error is the difference between a measured value and a true or accepted reference value of the quantity being measured.
Purpose
Identify different types and sources of analytical errors.
Understand the effects of random and systematic errors.
Distinguish gross mistakes from normal measurement variation.
Recognize methods for detecting and reducing analytical errors.
Understand the relationship between error, bias, and measurement uncertainty.
Key Concepts
| Term | Meaning |
|---|---|
Random error | An unpredictable variation that causes repeated measurements to scatter. |
Systematic error | A consistent or predictable effect that shifts measurements relative to a reference value. |
Gross error | A major mistake, often caused by incorrect procedure, recording, handling, or calculation. |
Absolute error | The difference between a measured value and a reference value. |
Relative error | Absolute error expressed relative to the reference value. |
Bias | An estimate of a systematic measurement effect. |
Measurement uncertainty | A parameter characterizing the dispersion of values that could reasonably be attributed to the measurand. |
Principle
Analytical errors arise because measurements are affected by imperfect sampling, preparation, equipment, procedures, environmental conditions, and human actions. Identifying the type and source of error helps determine whether the appropriate response is statistical evaluation, recalibration, method correction, improved sample handling, or investigation of a procedural mistake.
Types Of Errors
| Type | Characteristics | Effect | Examples | Control |
|---|---|---|---|---|
Random error | Causes scatter in repeated measurements and may vary in magnitude and direction. | Primarily affects precision. |
| Replicate measurements, stable conditions, suitable equipment, and statistical analysis. |
Systematic error | Produces a consistent or predictable deviation. | Primarily affects trueness. |
| Calibration, reference materials, recovery studies, blank correction, and method improvement. |
Gross error | A major mistake that may produce an obviously incorrect result. | Can severely affect an individual result or entire batch. |
| Documentation, independent checks, training, traceability, and investigation. |
Sources Of Errors
| Source | Description |
|---|---|
Sampling error | The collected sample does not adequately represent the target material. |
Instrumental error | Equipment calibration, drift, resolution, noise, or malfunction affects measurement. |
Method error | The analytical procedure introduces bias through incomplete reactions, interferences, or unsuitable assumptions. |
Personal error | Operator actions, judgement, reading, or recording introduce variation or mistakes. |
Reagent error | Impure, degraded, incorrectly prepared, or contaminated reagents affect the result. |
Environmental error | Temperature, humidity, vibration, dust, or other conditions influence the measurement. |
Analytical Process
Identify the stage at which the error may have occurred.
Check sample identity, sampling records, and sample preservation.
Inspect reagents, glassware, instrument calibration, and method conditions.
Use blanks, reference materials, control samples, and replicate measurements to investigate the problem.
Separate random scatter from systematic bias where possible.
Apply a justified correction or repeat the affected analytical stage when necessary.
Document the investigation and assess the effect on the final result.
Equations
| Name | Expression | Description |
|---|---|---|
Absolute error | E = xmeasured − xreference | Difference between a measured result and an accepted reference value. |
Relative error | Relative error = [(xmeasured − xreference)/xreference] × 100 | Absolute error expressed as a percentage of the reference value. |
Sample standard deviation | s = √[Σ(xᵢ − x̄)²/(n − 1)] | Quantifies the scatter of replicate measurements and is commonly used to evaluate random variation. |
Mean | x̄ = Σxᵢ/n | Arithmetic average of replicate results. |
Units
Same as the measured quantity for absolute error
% for relative error
Same as the measured quantity for standard deviation
Worked Examples
| Problem | Steps | Answer |
|---|---|---|
A reference material has an accepted concentration of 20.0 mg L⁻¹. A laboratory measures 19.2 mg L⁻¹. Calculate the absolute and relative error. |
| Absolute error = −0.8 mg L⁻¹ and relative error = −4.0%. The negative sign indicates that the measured value is lower than the reference value. |
Three replicate measurements are 10.1, 10.2, and 10.3 mg L⁻¹. Calculate the mean and sample standard deviation. |
| Mean = 10.2 mg L⁻¹ and sample standard deviation = 0.10 mg L⁻¹. |
Applications
Investigating unusual results in environmental analysis.
Monitoring instrument calibration and drift.
Evaluating method performance during validation.
Identifying errors in solution preparation and titration.
Assessing laboratory quality-control performance.
Advantages
Understanding error sources helps improve analytical procedures.
Replicate measurements provide information about random variation.
Reference materials help reveal systematic bias.
Documented investigations support reliable and traceable laboratory decisions.
Limitations
The true value is generally not known exactly.
Systematic errors may remain undetected without suitable reference information.
Repeating a measurement does not automatically remove systematic error.
A statistical outlier test cannot identify the chemical or procedural cause of an unusual result by itself.
Common Mistakes
Assuming that every error is random.
Believing that repeated measurements automatically eliminate bias.
Confusing measurement error with measurement uncertainty.
Deleting an unusual result without a documented technical reason.
Ignoring sampling error because the instrument appears to be working correctly.
Reporting relative error without stating the reference value used.
Learning Objectives
Define analytical error.
Differentiate random, systematic, and gross errors.
Identify common sources of analytical error.
Calculate absolute and relative error.
Explain how reference materials and replicate measurements help investigate errors.
Distinguish error from measurement uncertainty.
Practice Questions
Define random error and systematic error.
What is a gross error? Give two examples.
Differentiate between instrumental and method errors.
Why does repeating a measurement not necessarily eliminate systematic error?
A reference value is 15.0 mg L⁻¹ and a measured value is 14.4 mg L⁻¹. Calculate absolute and relative error.
How can a certified reference material help detect analytical bias?
Explain the difference between measurement error and measurement uncertainty.
Key Takeaways
Analytical measurements are affected by random, systematic, and gross errors.
Random errors mainly affect precision; systematic errors mainly affect trueness.
Sampling, instruments, reagents, methods, operators, and environmental conditions can all introduce errors.
Calibration, reference materials, blanks, and replicate measurements help investigate analytical performance.
Measurement error and measurement uncertainty are different concepts.
References
| Title | Authors | Edition | Type | Scope | Publisher | Url |
|---|---|---|---|---|---|---|
Quantitative Chemical Analysis | Daniel C. Harris and Charles A. Lucy | 10th edition | Textbook | Errors, statistics, calibration, and analytical measurement. | ||
International Vocabulary of Metrology (VIM), JCGM 200:2012 | Metrology reference | Measurement error, uncertainty, and related definitions. | Joint Committee for Guides in Metrology | https://www.bipm.org/en/committees/jc/jcgm/publications | ||
Eurachem Guide: Quantifying Uncertainty in Analytical Measurement | Technical guide | Evaluation and expression of measurement uncertainty. | https://eurachem.org/index.php/publications/guides |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry