✦ScienexySCIENCE KNOWLEDGE LIBRARY
topic · SCI-CHE-005-011

Errors in Chemical Analysis

Errors in chemical analysis are differences between measured results and the corresponding true or reference values. They may arise from random variation, systematic effects, or gross mistakes. Understanding their sources and behaviour helps analysts improve measurement quality and interpret uncertainty.

Explanation

No experimental measurement is completely free from error. In analytical chemistry, an error is the difference between a measured value and the true value or an accepted reference value of the measurand. Errors may arise during sampling, sample preparation, reagent preparation, calibration, measurement, calculation, or reporting.

Random errors produce unpredictable variation in repeated measurements. They may result from small uncontrolled changes in temperature, reading position, instrument noise, or other fluctuating conditions. Random errors mainly influence precision and can be studied using replicate measurements and statistical methods.

Systematic errors cause results to deviate in a consistent direction or according to a predictable pattern. They may arise from incorrect calibration, an impure reagent, a consistent volume-reading error, incomplete analyte recovery, or a method-related matrix effect. Systematic errors influence trueness and are not necessarily reduced by repeating the same measurement.

Gross errors are large mistakes caused by failures such as using the wrong reagent, recording an incorrect sample identity, misreading a scale, or making a major calculation error. Such events should be investigated and documented. A result should not be removed merely because it appears unusual.

Errors may also be classified according to their source. Instrumental errors arise from measurement equipment; personal errors arise from operator actions; method errors arise from limitations or assumptions in the procedure; and sampling errors arise when the collected portion does not represent the target material.

The distinction between error and uncertainty is important. Error is the difference between a measured value and a reference or true value. Measurement uncertainty describes the dispersion of values that could reasonably be attributed to the measurand. Since the true value is generally not known exactly, uncertainty is used to express the quality of the measurement result.

Error control requires appropriate sampling, calibration, blanks, reference materials, replicate measurements, instrument maintenance, validated procedures, and careful documentation.

Variables

SymbolMeaningUnit

E

Absolute error

Same as measurand

xmeasured

Measured value

Same as measurand

xreference

Accepted reference value

Same as measurand

xᵢ

Individual measurement

Same as measurand

x̄

Mean of replicate results

Same as measurand

s

Sample standard deviation

Same as measurand

n

Number of measurements

Dimensionless

Example or application

A worked example has not yet been added.

Definition

An analytical error is the difference between a measured value and a true or accepted reference value of the quantity being measured.

Purpose

  • Identify different types and sources of analytical errors.

  • Understand the effects of random and systematic errors.

  • Distinguish gross mistakes from normal measurement variation.

  • Recognize methods for detecting and reducing analytical errors.

  • Understand the relationship between error, bias, and measurement uncertainty.

Key Concepts

TermMeaning

Random error

An unpredictable variation that causes repeated measurements to scatter.

Systematic error

A consistent or predictable effect that shifts measurements relative to a reference value.

Gross error

A major mistake, often caused by incorrect procedure, recording, handling, or calculation.

Absolute error

The difference between a measured value and a reference value.

Relative error

Absolute error expressed relative to the reference value.

Bias

An estimate of a systematic measurement effect.

Measurement uncertainty

A parameter characterizing the dispersion of values that could reasonably be attributed to the measurand.

Principle

Analytical errors arise because measurements are affected by imperfect sampling, preparation, equipment, procedures, environmental conditions, and human actions. Identifying the type and source of error helps determine whether the appropriate response is statistical evaluation, recalibration, method correction, improved sample handling, or investigation of a procedural mistake.

Types Of Errors

TypeCharacteristicsEffectExamplesControl

Random error

Causes scatter in repeated measurements and may vary in magnitude and direction.

Primarily affects precision.

  • Small fluctuations in instrument signal.

  • Uncontrolled variation in endpoint judgement.

  • Minor changes in environmental conditions.

Replicate measurements, stable conditions, suitable equipment, and statistical analysis.

Systematic error

Produces a consistent or predictable deviation.

Primarily affects trueness.

  • Incorrect calibration.

  • Consistently impure reagent.

  • Incomplete analyte recovery.

  • Consistent volumetric glassware bias.

Calibration, reference materials, recovery studies, blank correction, and method improvement.

Gross error

A major mistake that may produce an obviously incorrect result.

Can severely affect an individual result or entire batch.

  • Using the wrong sample.

  • Recording the wrong balance reading.

  • Adding the wrong reagent.

  • Making a major dilution calculation mistake.

Documentation, independent checks, training, traceability, and investigation.

Sources Of Errors

SourceDescription

Sampling error

The collected sample does not adequately represent the target material.

Instrumental error

Equipment calibration, drift, resolution, noise, or malfunction affects measurement.

Method error

The analytical procedure introduces bias through incomplete reactions, interferences, or unsuitable assumptions.

Personal error

Operator actions, judgement, reading, or recording introduce variation or mistakes.

Reagent error

Impure, degraded, incorrectly prepared, or contaminated reagents affect the result.

Environmental error

Temperature, humidity, vibration, dust, or other conditions influence the measurement.

Analytical Process

  • Identify the stage at which the error may have occurred.

  • Check sample identity, sampling records, and sample preservation.

  • Inspect reagents, glassware, instrument calibration, and method conditions.

  • Use blanks, reference materials, control samples, and replicate measurements to investigate the problem.

  • Separate random scatter from systematic bias where possible.

  • Apply a justified correction or repeat the affected analytical stage when necessary.

  • Document the investigation and assess the effect on the final result.

Equations

NameExpressionDescription

Absolute error

E = xmeasured − xreference

Difference between a measured result and an accepted reference value.

Relative error

Relative error = [(xmeasured − xreference)/xreference] × 100

Absolute error expressed as a percentage of the reference value.

Sample standard deviation

s = √[Σ(xᵢ − x̄)²/(n − 1)]

Quantifies the scatter of replicate measurements and is commonly used to evaluate random variation.

Mean

x̄ = Σxᵢ/n

Arithmetic average of replicate results.

Units

  • Same as the measured quantity for absolute error

  • % for relative error

  • Same as the measured quantity for standard deviation

Worked Examples

ProblemStepsAnswer

A reference material has an accepted concentration of 20.0 mg L⁻¹. A laboratory measures 19.2 mg L⁻¹. Calculate the absolute and relative error.

  • Measured value = 19.2 mg L⁻¹.

  • Reference value = 20.0 mg L⁻¹.

  • Absolute error = 19.2 − 20.0 = −0.8 mg L⁻¹.

  • Relative error = (−0.8/20.0) × 100.

Absolute error = −0.8 mg L⁻¹ and relative error = −4.0%. The negative sign indicates that the measured value is lower than the reference value.

Three replicate measurements are 10.1, 10.2, and 10.3 mg L⁻¹. Calculate the mean and sample standard deviation.

  • Mean = (10.1 + 10.2 + 10.3)/3 = 10.2 mg L⁻¹.

  • Deviations are −0.1, 0.0, and +0.1 mg L⁻¹.

  • Sum of squared deviations = 0.01 + 0 + 0.01 = 0.02.

  • Sample variance = 0.02/(3 − 1) = 0.01.

  • Sample standard deviation = √0.01 = 0.10 mg L⁻¹.

Mean = 10.2 mg L⁻¹ and sample standard deviation = 0.10 mg L⁻¹.

Applications

  • Investigating unusual results in environmental analysis.

  • Monitoring instrument calibration and drift.

  • Evaluating method performance during validation.

  • Identifying errors in solution preparation and titration.

  • Assessing laboratory quality-control performance.

Advantages

  • Understanding error sources helps improve analytical procedures.

  • Replicate measurements provide information about random variation.

  • Reference materials help reveal systematic bias.

  • Documented investigations support reliable and traceable laboratory decisions.

Limitations

  • The true value is generally not known exactly.

  • Systematic errors may remain undetected without suitable reference information.

  • Repeating a measurement does not automatically remove systematic error.

  • A statistical outlier test cannot identify the chemical or procedural cause of an unusual result by itself.

Common Mistakes

  • Assuming that every error is random.

  • Believing that repeated measurements automatically eliminate bias.

  • Confusing measurement error with measurement uncertainty.

  • Deleting an unusual result without a documented technical reason.

  • Ignoring sampling error because the instrument appears to be working correctly.

  • Reporting relative error without stating the reference value used.

Learning Objectives

  • Define analytical error.

  • Differentiate random, systematic, and gross errors.

  • Identify common sources of analytical error.

  • Calculate absolute and relative error.

  • Explain how reference materials and replicate measurements help investigate errors.

  • Distinguish error from measurement uncertainty.

Practice Questions

  • Define random error and systematic error.

  • What is a gross error? Give two examples.

  • Differentiate between instrumental and method errors.

  • Why does repeating a measurement not necessarily eliminate systematic error?

  • A reference value is 15.0 mg L⁻¹ and a measured value is 14.4 mg L⁻¹. Calculate absolute and relative error.

  • How can a certified reference material help detect analytical bias?

  • Explain the difference between measurement error and measurement uncertainty.

Key Takeaways

  • Analytical measurements are affected by random, systematic, and gross errors.

  • Random errors mainly affect precision; systematic errors mainly affect trueness.

  • Sampling, instruments, reagents, methods, operators, and environmental conditions can all introduce errors.

  • Calibration, reference materials, blanks, and replicate measurements help investigate analytical performance.

  • Measurement error and measurement uncertainty are different concepts.

References

TitleAuthorsEditionTypeScopePublisherUrl

Quantitative Chemical Analysis

Daniel C. Harris and Charles A. Lucy

10th edition

Textbook

Errors, statistics, calibration, and analytical measurement.

International Vocabulary of Metrology (VIM), JCGM 200:2012

Metrology reference

Measurement error, uncertainty, and related definitions.

Joint Committee for Guides in Metrology

https://www.bipm.org/en/committees/jc/jcgm/publications

Eurachem Guide: Quantifying Uncertainty in Analytical Measurement

Technical guide

Evaluation and expression of measurement uncertainty.

https://eurachem.org/index.php/publications/guides

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Analytical Chemistry