✦ScienexySCIENCE KNOWLEDGE LIBRARY
topic · SCI-CHE-005-017

Sample Collection and Preservation

Sample collection and preservation are procedures used to obtain material and maintain its chemical, physical, and biological characteristics until analysis. Appropriate containers, collection techniques, storage conditions, and holding times are essential for preventing contamination and analyte changes.

Explanation

A sample may change between collection and measurement. Chemical reactions, microbial activity, oxidation, reduction, precipitation, adsorption onto container walls, volatilization, photodegradation, and temperature changes can alter the concentration or form of an analyte. Sample preservation is intended to minimize these changes while maintaining the property required by the analytical method. The correct procedure depends on the analyte and matrix. For example, dissolved-metal analysis may require filtration and acidification according to the method, whereas volatile organic compounds require containers and handling procedures designed to minimize volatilization and headspace. These treatments are not universal: preservation appropriate for one analyte may destroy or alter another. Container material must be compatible with the sample and analyte. Glass, plastics, and specialized containers have different adsorption, leaching, and chemical-resistance characteristics. Storage temperature, protection from light, chemical preservatives, and maximum holding time must be established from the relevant validated method or standard. Collection records should include sample identification, location, time, collector, container, preservation, temperature, and any unusual conditions.

Variables

SymbolMeaningUnit

Cₜ

Concentration after storage time t

Same as the initial concentration

C₀

Initial concentration

mg/L, mol/L, or another concentration unit

k

First-order rate constant

Time⁻¹

t

Elapsed storage time

s, min, h, or day

t₁/₂

First-order half-life

Same time unit used for k

Example or application

A worked example has not yet been added.

Definition

Sample collection is the controlled acquisition of material from a defined population, while sample preservation is the application of suitable conditions or treatments to maintain the required sample characteristics until analysis.

Purpose

To obtain a valid sample and minimize changes in analyte concentration, chemical form, or physical condition before laboratory measurement.

Importance

Improper collection or preservation can cause analyte loss, contamination, or transformation. These changes may produce results that do not reflect the material at the time or place of collection.

Key Concepts

  • Sample integrity: preservation of the sample's relevant properties.

  • Holding time: the maximum permitted time between collection and analysis or a specified preparation step.

  • Preservative: a treatment used to minimize sample changes.

  • Container compatibility: suitability of a container for the analyte and matrix.

  • Volatilization: loss of volatile substances into the surrounding gas phase.

  • Adsorption: accumulation of analyte on a surface.

  • Photodegradation: chemical change caused by light exposure.

  • Biological degradation: alteration caused by microorganisms or biological activity.

  • Chain of custody: documented control and transfer history of a sample, especially important in regulated or forensic work.

  • Field blank: a blank exposed to field conditions to assess contamination introduced during sampling and handling.

Principle

Preservation must be selected according to the analyte, matrix, measurement objective, and validated analytical procedure. The goal is not to make every sample chemically inert; it is to maintain the property being measured within acceptable limits until analysis. Collection and preservation conditions must therefore be documented and method-specific.

Working Process

  • Identify the analyte, matrix, analytical method, and required sample type.

  • Consult the applicable validated method for container, preservation, and holding-time requirements.

  • Prepare clean and compatible containers and appropriate sampling equipment.

  • Collect the sample while avoiding contamination and unwanted changes.

  • Apply the required filtration, cooling, chemical preservation, or light protection when specified.

  • Label each container with a unique identifier and collection information.

  • Transport the sample under controlled conditions.

  • Store the sample according to the method and analyze it within the specified holding time.

  • Document preservation, storage, transport, and any deviations.

Equations

NameExpressionDescriptionConditions

First-order concentration change model

Cₜ = C₀e⁻ᵏᵗ

Describes concentration change when analyte loss follows first-order kinetics under defined conditions. It can illustrate why storage time matters but should not be assumed to describe every sample degradation process.

The process must follow first-order kinetics with an approximately constant rate constant.

First-order half-life

t₁/₂ = ln(2) / k

The time required for a first-order process to reduce the original concentration by half.

Applicable to first-order decay or loss.

Units

  • Storage temperature: °C or K

  • Holding time: h or day

  • Sample volume: mL or L

  • Analyte concentration: mg/L, µg/L, or another appropriate unit

  • Sample mass: g or kg

Examples

TitleProblemSolutionAnswerLearning Point

Effect of storage time on a first-order unstable analyte

An analyte has an initial concentration of 100 mg/L and a first-order loss constant of 0.10 day⁻¹. Estimate its concentration after 5 days if no effective preservation is applied.

Cₜ = C₀e⁻ᵏᵗ = 100 × e⁻⁽⁰·¹⁰×⁵⁾ = 100 × e⁻⁰·⁵ ≈ 60.7 mg/L.

The estimated concentration is approximately 60.7 mg/L.

The calculation illustrates the possible effect of analyte instability. Actual holding times must be established using method-specific evidence.

Preservation of a water sample for dissolved metals

A water sample is collected for dissolved-metal analysis.

The sampling procedure must specify filtration and preservation requirements. If dissolved concentration is required, filtration must be performed according to the applicable method, and the prescribed acidification and storage procedure must be followed.

Filtration and preservation can define which chemical fraction is measured, so they must match the analytical objective.

Applications

  • Collection of drinking-water and wastewater samples.

  • Preservation of environmental samples for trace-metal analysis.

  • Collection of food and pharmaceutical samples.

  • Clinical specimen collection and transport.

  • Forensic evidence sampling and chain-of-custody documentation.

  • Industrial process monitoring and product quality control.

Advantages

  • Maintains sample integrity during transport and storage.

  • Reduces analyte loss and unwanted chemical transformation.

  • Improves comparability between sampling events.

  • Supports defensible laboratory and regulatory results.

Limitations

  • No preservation procedure is suitable for every analyte.

  • Some preservatives can interfere with later measurements.

  • Cooling or acidification may not stop all biological or chemical changes.

  • Container adsorption and contamination may remain significant at trace concentrations.

  • Holding times vary with analyte, matrix, method, and storage conditions.

Common Mistakes

  • Using one preservation procedure for all analytes.

  • Ignoring container compatibility.

  • Assuming refrigeration prevents every chemical change.

  • Exceeding method-specific holding times.

  • Failing to record collection and preservation details.

  • Acidifying a sample without considering whether the analytical method requires dissolved or total analyte measurement.

  • Leaving unnecessary headspace in samples intended for volatile-analyte analysis.

Prerequisites

  • Introduction to analytical sampling.

  • Sampling techniques and strategies.

  • Basic chemical equilibrium and reaction concepts.

Learning Objectives

  • Explain why samples require preservation.

  • Identify common mechanisms of analyte change during storage.

  • Explain the importance of container compatibility.

  • Define holding time and chain of custody.

  • Describe the general procedure for collecting and preserving a sample.

  • Explain why preservation requirements must be analyte- and method-specific.

Practice Questions

  • Why can a sample change between collection and analysis?

  • Define sample integrity and holding time.

  • How can volatilization and adsorption affect analytical results?

  • Why is the same preservation procedure not appropriate for every analyte?

  • What information should be recorded during sample collection?

  • Explain the role of chain-of-custody documentation.

Key Takeaway

A sample must remain suitable for its intended measurement from collection to analysis. Correct preservation is method-specific and must be documented rather than assumed.

References

TitleAuthorsTypeRelevance

Standard Methods for the Examination of Water and Wastewater

APHA, AWWA, and WEF

standard analytical reference

Water sample collection, preservation, and analytical procedures.

ISO 5667 Series: Water Quality — Sampling

international standard series

Water sampling and sample handling principles.

Quantitative Chemical Analysis

Daniel C. Harris and Charles A. Lucy

textbook

Sample handling and analytical reliability.

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Analytical Chemistry