✦ScienexySCIENCE KNOWLEDGE LIBRARY
topic · SCI-CHE-005-051

Acid–Base Indicators and Indicator Selection

Acid–base indicators are substances whose colours depend on pH. They are used to detect titration endpoints, and the appropriate indicator is selected by comparing its transition range with the steep pH-change region of the titration curve.

Explanation

Most acid–base indicators are weak organic acids or bases whose protonated and deprotonated forms have different colours. A simplified indicator equilibrium can be written as HIn ⇌ H⁺ + In⁻. The relative amounts of HIn and In⁻ change as the solution pH changes, producing a visible colour transition. The transition is not normally restricted to a single pH value; it occurs over a range in which both forms are present in appreciable amounts. For a successful titration, the indicator's transition range should fall within the steep portion of the titration curve near the equivalence point. The best indicator depends on the strengths of the acid and base being titrated. Phenolphthalein is commonly suitable for weak-acid–strong-base titrations, while methyl orange can be suitable for strong-acid–weak-base titrations. No single indicator is ideal for every acid–base titration.

Variables

SymbolMeaningUnit

HIn

Protonated indicator form

Not applicable

In⁻

Deprotonated indicator form

Not applicable

pH

Negative logarithm of hydrogen-ion activity

Dimensionless

pKₐ

Negative logarithm of the indicator acid-dissociation constant

Dimensionless

Example or application

A worked example has not yet been added.

Definition

An acid–base indicator is a substance that exhibits a visible colour change over a characteristic pH range because its chemical forms have different colours.

Purpose

To provide a visible signal for identifying the endpoint of an acid–base titration.

Importance

Correct indicator selection reduces endpoint error. It is especially important when the pH at the equivalence point is not 7, as occurs in titrations involving weak acids or weak bases.

Key Concepts

  • The two indicator forms generally have different colours.

  • The indicator equilibrium responds to hydrogen-ion activity and therefore to pH.

  • The transition range is the pH interval over which the visible colour changes.

  • The equivalence-point pH depends on the strengths of the acid and base.

  • An indicator should change colour within the steep region of the titration curve.

  • Only a small amount of indicator should normally be used to minimize its effect on the solution.

Principle

An indicator exists in two or more forms with different colours. A change in pH shifts the equilibrium between these forms, producing a visible colour change when their relative proportions change sufficiently.

Working Process

  • Identify whether the titration involves a strong or weak acid and a strong or weak base.

  • Determine or estimate the pH near the equivalence point.

  • Examine the steep pH-change region of the titration curve.

  • Select an indicator whose transition range lies within that region.

  • Add only a few drops of the indicator to the analyte solution.

  • Observe the colour change while approaching the endpoint slowly.

  • Use the same endpoint colour criterion consistently across replicate titrations.

Equations

NameExpressionDescription

Indicator equilibrium

HIn ⇌ H⁺ + In⁻

A simplified equilibrium for an indicator behaving as a weak acid; HIn and In⁻ have different colours.

Indicator transition relationship

pH = pKₐ + log([In⁻] / [HIn])

The Henderson–Hasselbalch form for the indicator equilibrium, under the usual approximation that activities can be represented by concentrations.

Units

  • pH: dimensionless

  • pKₐ: dimensionless

  • Transition range: pH units

Examples

  • Phenolphthalein changes from colourless to pink over an alkaline transition range and is commonly used for a weak-acid–strong-base titration.

  • Methyl orange changes from red through orange to yellow over an acidic transition range and can be suitable for a strong-acid–weak-base titration.

Applications

  • Endpoint detection in acid–base titrations.

  • Routine determination of acid and base concentrations.

  • Monitoring pH changes in educational and analytical laboratories.

  • Selection of visual endpoints in food, water, and chemical analysis.

Advantages

  • Simple and inexpensive to use.

  • Provides a rapid visual endpoint.

  • Requires no electronic detector.

  • Many indicators cover different pH transition ranges.

Limitations

  • Visual colour assessment can be subjective.

  • Coloured or cloudy samples can obscure the indicator change.

  • The indicator itself may slightly affect the solution when used in excessive quantity.

  • An indicator is unsuitable if its transition range falls outside the steep region near equivalence.

  • Some titrations require potentiometric endpoint detection instead of a visual indicator.

Common Mistakes

  • Assuming every acid–base titration has an equivalence point at pH 7.

  • Selecting an indicator without considering the titration curve.

  • Adding too much indicator.

  • Stopping at the first temporary colour change rather than the defined persistent endpoint.

  • Comparing colours under substantially different lighting conditions.

Prerequisites

  • Acid–base equilibria.

  • pH and pKₐ.

  • Weak acids and weak bases.

  • Acid–base titration curves.

Learning Objectives

  • Explain how acid–base indicators change colour.

  • Describe the transition range of an indicator.

  • Relate indicator selection to the equivalence-point region.

  • Choose suitable indicators for common acid–base titrations.

  • Identify situations in which visual indicators may be unreliable.

Practice Questions

  • Why do acid–base indicators change colour with pH?

  • What is meant by an indicator transition range?

  • Why is phenolphthalein commonly used for weak-acid–strong-base titrations?

  • Why is methyl orange suitable for some strong-acid–weak-base titrations?

  • What problems can arise when an indicator is used in a coloured sample?

Key Takeaway

The best acid–base indicator is not simply the most familiar one; its transition range must overlap the steep pH-change region near the titration's equivalence point.

References

TitleTypeUrl

Harris, Quantitative Chemical Analysis

textbook

Skoog, West, Holler and Crouch, Fundamentals of Analytical Chemistry

textbook

IUPAC Gold Book

terminology reference

https://goldbook.iupac.org/

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Analytical Chemistry