Potassium dichromate is a stable oxidizing reagent that can be obtained in high purity and is suitable as a primary standard after appropriate drying and handling. In acidic solution, the dichromate ion oxidizes reducing agents and is reduced to chromium(III). Unlike potassium permanganate, dichromate does not normally provide a sufficiently distinct self-indicating endpoint, so a suitable redox indicator or instrumental endpoint method is generally required. Diphenylamine sulfonate and related indicators are used in certain dichromate titrations. The reaction is commonly carried out in sulfuric-acid medium. Phosphoric acid may be added in some iron(II) determinations to complex iron(III) and improve the indicator endpoint. Because chromium(VI) compounds are hazardous, their use requires strict laboratory safety procedures and appropriate waste management.
Dichromate Titration
Dichromate titration is a redox method that uses potassium dichromate as an oxidizing titrant, commonly in acidic solution. Dichromate is reduced from chromium(VI) to chromium(III), accepting six electrons per dichromate ion.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
Cr₂O₇²⁻ | Dichromate ion | Not applicable |
Cr³⁺ | Chromium(III) ion | Not applicable |
Fe²⁺ | Iron(II) ion | Not applicable |
C | Molar concentration | mol L⁻¹ |
V | Solution volume | L |
Example or application
A worked example has not yet been added.
Definition
Dichromate titration is a redox titration in which potassium dichromate acts as the standard oxidizing agent.
Purpose
To determine reducing substances, particularly iron(II), through a quantitative oxidation reaction with dichromate.
Importance
Potassium dichromate is useful because it is stable, can be prepared as a primary standard, and has a well-defined redox reaction in acidic medium.
Key Concepts
Dichromate ion contains chromium in the +6 oxidation state.
In acidic solution, dichromate is reduced to chromium(III).
Each dichromate ion accepts six electrons.
Potassium dichromate can serve as a primary standard.
A redox indicator is usually needed to detect the endpoint.
Chromium(VI) compounds require careful handling because of their toxicity and environmental hazards.
Principle
In acidic solution, dichromate accepts six electrons and oxidizes the reducing analyte. The equivalence point is calculated from the balanced redox reaction, while a redox indicator or electrode identifies the endpoint.
Working Process
Prepare a potassium dichromate standard solution using accurately weighed, suitably conditioned reagent.
Pipette a measured amount of reducing analyte into a titration flask.
Add the required acidic medium, commonly sulfuric acid.
Add any necessary complexing reagent or indicator according to the validated procedure.
Deliver dichromate solution from a burette while mixing.
Approach the endpoint carefully and observe the indicator response or electrode potential.
Record the titrant volume and repeat as required.
Calculate the analyte amount using the balanced redox equation.
Collect chromium-containing waste for appropriate hazardous-waste disposal.
Equations
| Name | Expression | Description |
|---|---|---|
Dichromate reduction in acidic solution | Cr₂O₇²⁻ + 14H⁺ + 6e⁻ → 2Cr³⁺ + 7H₂O | One dichromate ion accepts six electrons in acidic medium. |
Oxidation of iron(II) by dichromate | Cr₂O₇²⁻ + 6Fe²⁺ + 14H⁺ → 2Cr³⁺ + 6Fe³⁺ + 7H₂O | One mole of dichromate reacts with six moles of iron(II) under the stated conditions. |
Units
Concentration: mol L⁻¹
Volume: mL or L
Amount of substance: mol or mmol
Examples
The balanced reaction shows that 1 mol of Cr₂O₇²⁻ oxidizes 6 mol of Fe²⁺. Therefore, 0.00150 mol of dichromate corresponds to 0.00900 mol of iron(II), assuming the reaction proceeds quantitatively.
Applications
Determination of iron(II) in ores and iron-containing solutions.
Standardization and analysis of reducing-agent solutions.
Certain industrial and environmental redox analyses.
Reference redox procedures in analytical laboratories.
Advantages
Potassium dichromate is stable under appropriate storage conditions.
High-purity potassium dichromate can be used as a primary standard.
Its acidic redox stoichiometry is well established.
The solution can provide reproducible quantitative results when properly prepared.
Limitations
Chromium(VI) compounds are toxic and require strict handling and disposal controls.
A separate indicator or instrumental endpoint method is generally required.
The reaction medium must be controlled.
Other reducing substances in the sample may consume dichromate and cause positive interference.
Common Mistakes
Assuming dichromate is self-indicating in the same way as permanganate.
Using an unsuitable indicator for the redox system.
Failing to provide sufficient acidic conditions.
Ignoring the six-electron stoichiometry of dichromate reduction.
Treating chromium-containing waste as ordinary laboratory waste.
Prerequisites
Oxidation states and redox reactions.
Balancing redox equations.
Primary standards and standard solutions.
Volumetric analysis.
Laboratory chemical safety.
Learning Objectives
Explain the principle of dichromate titration.
Write the dichromate reduction half-reaction in acidic medium.
Calculate the analyte amount using the six-electron stoichiometry.
Explain why an indicator is generally required.
Describe the safety concerns associated with chromium(VI).
Practice Questions
What is the oxidation state of chromium in dichromate?
How many electrons does one dichromate ion accept in acidic solution?
Why can potassium dichromate be used as a primary standard?
Why is a separate indicator generally required in dichromate titration?
How many moles of Fe²⁺ react with 0.00200 mol of dichromate?
Key Takeaway
Dichromate titration relies on the six-electron reduction of Cr₂O₇²⁻ to Cr³⁺ in acidic solution; its stability is useful analytically, but chromium(VI) hazards require careful controls.
References
| Title | Type | Url |
|---|---|---|
Harris, Quantitative Chemical Analysis | textbook | |
Skoog, West, Holler and Crouch, Fundamentals of Analytical Chemistry | textbook | |
IUPAC Gold Book | terminology reference | https://goldbook.iupac.org/ |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry