Argentometric titrations use silver ions, commonly supplied by silver nitrate, to precipitate halide ions. The Mohr method is a direct titration in which chloride or bromide is titrated with silver nitrate using chromate as an indicator. After the halide has been precipitated, a slight excess of silver ions reacts with chromate to produce a reddish-brown silver chromate endpoint. The method requires a suitable pH because strongly acidic conditions alter chromate speciation and alkaline conditions may cause other silver precipitates. The Volhard method commonly uses thiocyanate to titrate excess silver ions in an acidic medium, with iron(III) serving as an indicator. A red iron(III)–thiocyanate complex signals excess thiocyanate. It can be used in a back-titration procedure for halides. The Fajans method uses an adsorption indicator whose colour changes when it adsorbs onto the surface of the precipitate near equivalence. Its endpoint behaviour depends on the surface charge of the precipitate and the indicator's ionic character. The choice among these methods depends on sample composition, pH, precipitate properties, and indicator compatibility.
Mohr, Volhard, and Fajans Methods
Mohr, Volhard, and Fajans methods are classical argentometric titration procedures used mainly for halide determination. They differ in their endpoint detection mechanisms and the conditions under which they are performed.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
Ag⁺ | Silver ion | Not applicable |
X⁻ | Halide ion | Not applicable |
CrO₄²⁻ | Chromate ion | Not applicable |
SCN⁻ | Thiocyanate ion | Not applicable |
Fe³⁺ | Iron(III) ion | Not applicable |
n | Amount of substance | mol |
C | Molar concentration | mol L⁻¹ |
V | Solution volume | L |
Example or application
A worked example has not yet been added.
Definition
Mohr, Volhard, and Fajans methods are three classical argentometric titration procedures that determine halide ions or silver ions using different endpoint detection mechanisms.
Purpose
To determine halide concentrations, especially chloride, by precipitation with silver ions and to identify the endpoint through chromate formation, iron(III)–thiocyanate complex formation, or adsorption-indicator behaviour.
Importance
These methods are foundational procedures in precipitation titrimetry and illustrate how chemical indicators, complex formation, and precipitate surface properties can be used to detect endpoints.
Key Concepts
Argentometric titration uses silver ions as a precipitating reagent.
The Mohr method uses chromate indicator and a reddish-brown silver chromate endpoint.
The Volhard method uses thiocyanate titration and an iron(III) indicator complex.
The Fajans method uses an adsorption indicator that responds to precipitate surface charge.
The Mohr method requires a controlled pH range.
The Volhard method is commonly performed in acidic medium.
The Fajans endpoint depends on adsorption and surface-charge changes near equivalence.
Principle
All three methods rely on the precipitation of silver salts, but the endpoint is detected differently: formation of a coloured silver chromate precipitate in Mohr titration, formation of a coloured iron(III)–thiocyanate complex in Volhard titration, or adsorption of an indicator onto the precipitate surface in Fajans titration.
Working Process
For the Mohr method, prepare the halide sample, adjust it to a suitable pH, and add a small amount of chromate indicator.
Titrate directly with standardized silver nitrate while mixing until a persistent reddish-brown silver chromate colour appears.
For the Volhard method, add a known excess of standard silver nitrate to the halide sample under suitable acidic conditions.
Separate the silver halide precipitate when required by the validated procedure.
Titrate the remaining excess silver ions with standard thiocyanate using iron(III) indicator.
Calculate the halide amount from the difference between silver added and silver remaining.
For the Fajans method, add a suitable adsorption indicator to the sample and titrate with silver nitrate.
Observe the indicator colour change associated with adsorption near the equivalence point.
Use the balanced reactions and recorded volumes to calculate the analyte concentration.
Equations
| Name | Expression | Description |
|---|---|---|
Halide precipitation | Ag⁺ + X⁻ → AgX(s) | Silver ions precipitate halide ions, where X⁻ represents chloride, bromide, or iodide when the method conditions are suitable. |
Mohr endpoint reaction | 2Ag⁺ + CrO₄²⁻ → Ag₂CrO₄(s) | A slight excess of silver ions forms reddish-brown silver chromate after the halide has been precipitated. |
Volhard endpoint reaction | Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺ | Excess thiocyanate forms a red iron(III)–thiocyanate complex. |
Volhard back-titration calculation | n(X⁻) = n(Ag⁺ added) − n(SCN⁻ used) | For a 1:1 silver-halide reaction and 1:1 silver-thiocyanate reaction, the halide amount is obtained by subtracting the residual silver amount from the amount initially added. |
Units
Concentration: mol L⁻¹
Volume: mL or L
Amount of substance: mol or mmol
Examples
In a Volhard back titration, 25.00 mL of 0.1000 mol L⁻¹ AgNO₃ is added to a halide sample. The excess silver requires 8.00 mL of 0.1000 mol L⁻¹ thiocyanate. The initial silver amount is 0.002500 mol, and the remaining silver amount is 0.000800 mol. The halide amount is therefore 0.001700 mol, assuming 1:1 precipitation and back-titration reactions.
Applications
Determination of chloride in water and saline samples.
Analysis of halides in food and pharmaceutical products.
Determination of chloride in industrial process solutions.
Classical argentometric analysis in teaching and quality-control laboratories.
Advantages
Provides several endpoint options for different sample conditions.
The underlying silver-halide precipitation reactions are well established.
Volhard back titration can be useful when direct visual endpoint detection is unsuitable.
Fajans indicators can provide sensitive endpoints in appropriate systems.
Limitations
Mohr titration is sensitive to pH and may be affected by other ions that form silver precipitates.
Volhard titration may require precipitate separation or careful control of interactions with the silver halide.
Fajans indicators depend on suitable precipitate surface properties and adsorption behaviour.
Chromate reagents contain hazardous chromium(VI) species and require appropriate handling and disposal.
Coloured or turbid samples can make visual endpoints difficult.
Common Mistakes
Using the Mohr method outside its suitable pH range.
Confusing the reddish-brown silver chromate endpoint with the white silver halide precipitate.
Failing to subtract the thiocyanate back-titration amount in the Volhard method.
Ignoring adsorption-indicator behaviour in the Fajans method.
Using chromate-containing waste disposal practices that are not appropriate for hazardous chromium waste.
Prerequisites
Precipitation reactions and solubility product.
Argentometric titration.
Complex-ion formation.
Indicators and adsorption.
Molarity and back-titration calculations.
Learning Objectives
Describe the endpoint principle of the Mohr method.
Explain the Volhard direct and back-titration approaches.
Describe how adsorption indicators work in the Fajans method.
Compare the pH and indicator requirements of the three methods.
Calculate halide content using argentometric titration data.
Practice Questions
Which indicator is used in the Mohr method?
What produces the reddish-brown endpoint in Mohr titration?
What is the role of iron(III) in the Volhard method?
How does the Fajans method detect its endpoint?
Why is a back-titration calculation needed in a typical Volhard determination?
Key Takeaway
Mohr, Volhard, and Fajans methods all use silver-salt precipitation, but their endpoint signals are different: coloured precipitate formation, coloured complex formation, and indicator adsorption.
References
| Title | Type |
|---|---|
Harris, Quantitative Chemical Analysis | textbook |
Skoog, West, Holler and Crouch, Fundamentals of Analytical Chemistry | textbook |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry