In voltammetry, a controlled potential is applied to a working electrode relative to a reference electrode, and the resulting current is measured. The current arises from oxidation or reduction of electroactive species at the electrode surface. Its magnitude and shape depend on analyte concentration, electron-transfer kinetics, electrode material, mass transport, and the potential program. A supporting electrolyte is often added to reduce migration effects and improve the controlled transport of analyte by diffusion. The resulting current-potential plot is called a voltammogram. Different potential waveforms and electrode arrangements produce techniques such as linear sweep voltammetry, differential pulse voltammetry, square-wave voltammetry, and cyclic voltammetry.
Voltammetry and Its Basic Principles
Voltammetry is an electroanalytical technique that measures current as a function of applied electrode potential to investigate and quantify electroactive substances.
Explanation
Variables
| Symbol | Name | Description |
|---|---|---|
I | Current | Electrical current measured at the working electrode. |
Q | Charge | Total charge transferred. |
n | Electron number | Number of electrons transferred per reacting species. |
F | Faraday constant | Approximately 96485 C mol⁻¹. |
ip | Peak current | Maximum current associated with an electrochemical peak. |
A | Electrode area | Area of the working electrode in contact with the solution. |
D | Diffusion coefficient | Measure of analyte diffusion. |
C | Analyte concentration | Bulk concentration of the electroactive species. |
v | Scan rate | Rate at which the applied potential changes. |
Example or application
A worked example has not yet been added.
Definition
Voltammetry is an electroanalytical method in which current is measured while the potential of a working electrode is controlled or varied.
Purpose
To identify electroactive species, determine their concentrations, investigate redox behavior, and study electron-transfer and mass-transport processes.
Importance
Voltammetry can provide sensitive analysis of trace electroactive substances and useful information about redox potentials, reaction mechanisms, and electrode kinetics.
Key Concepts
Working electrode: Electrode at which the analyte undergoes oxidation or reduction.
Reference electrode: Provides a stable potential reference.
Counter electrode: Completes the electrical circuit.
Voltammogram: Plot of current against applied potential.
Faradaic current: Current associated with electron-transfer reactions.
Capacitive current: Current associated with charging the electrode double layer.
Diffusion: Movement of analyte caused by concentration gradients.
Supporting electrolyte: Added electrolyte that helps control solution resistance and migration.
Principle
A potential is applied to the working electrode to drive an electrochemical reaction. When the potential reaches a region where the analyte can be oxidized or reduced, a Faradaic current develops. Under suitable controlled conditions, this current is related to analyte concentration and mass transport.
Working Process
Prepare the sample and add a suitable supporting electrolyte when required.
Choose a compatible working electrode, reference electrode, and counter electrode.
Clean or condition the working electrode according to the method.
Remove dissolved oxygen when it interferes with the analyte measurement.
Set the potential range and waveform appropriate to the analyte.
Apply the potential program using a potentiostat.
Record current as a function of applied potential.
Interpret peak or wave positions for qualitative information.
Use calibration or an appropriate theoretical model to determine concentration.
Equations
| Name | Formula | Meaning |
|---|---|---|
Faraday's law | Q = nFN | Relates charge to the amount of substance transformed in an electrochemical reaction. |
Current | I = dQ/dt | Current is the rate of transfer of electrical charge. |
Randles–Ševčík equation at 25 °C | ip = 2.69 × 10^5 n^(3/2) A D^(1/2) C v^(1/2) | For a reversible, diffusion-controlled peak in cyclic voltammetry, using the conventional units A in cm², D in cm² s⁻¹, C in mol cm⁻³, and scan rate v in V s⁻¹. |
Units
Potential: volt (V)
Current: ampere (A) or microampere (µA)
Charge: coulomb (C)
Electrode area: cm² or m²
Diffusion coefficient: cm² s⁻¹ or m² s⁻¹
Concentration: mol cm⁻³ or mol L⁻¹
Scan rate: V s⁻¹
Examples
Determining the concentration of a dissolved metal ion from its reduction current.
Investigating the oxidation potential of an organic compound.
Studying the redox behavior of a pharmaceutical compound.
Comparing electrochemical responses at different electrode materials.
Applications
Trace metal analysis.
Pharmaceutical and biochemical analysis.
Environmental monitoring.
Investigation of redox mechanisms.
Characterization of electrode materials.
Electrochemical sensor development.
Advantages
Can achieve high sensitivity for suitable analytes.
Provides both qualitative and quantitative information.
Can investigate reaction kinetics and mechanisms.
Requires relatively small sample volumes.
Several voltammetric waveforms can be selected for different analytical needs.
Limitations
Only species with suitable electrochemical responses can be measured directly.
Electrode fouling can reduce reproducibility.
Background and capacitive currents may interfere with weak signals.
Dissolved oxygen may interfere in some potential ranges.
Results depend on electrode condition and experimental parameters.
Common Mistakes
Confusing applied potential with measured current.
Ignoring capacitive background current.
Using an unsuitable potential window.
Failing to clean the working electrode.
Assuming every voltammetric peak is controlled only by analyte concentration.
Prerequisites
Electrochemical cells and electrode potentials.
Oxidation and reduction.
Diffusion and mass transport.
Basic electrical measurements.
Learning Objectives
Define voltammetry.
Identify the three main electrodes in a typical three-electrode system.
Explain the formation of Faradaic and capacitive currents.
Interpret the basic features of a voltammogram.
Recognize the influence of concentration and scan rate on current.
Practice Questions
What is voltammetry?
What is the function of a working electrode?
Why is a reference electrode used?
What information does a voltammogram provide?
Differentiate Faradaic current and capacitive current.
Why is a supporting electrolyte commonly added?
Key Takeaway
Voltammetry studies electroactive substances by controlling electrode potential and measuring the resulting current, providing information about both concentration and redox behavior.
References
| Title | Type | Url |
|---|---|---|
Bard and Faulkner, Electrochemical Methods: Fundamentals and Applications | textbook | |
Wang, Analytical Electrochemistry | textbook | |
IUPAC Gold Book | terminology reference | https://goldbook.iupac.org/ |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry