Amperometry is an electroanalytical method in which the current is measured while the working electrode is maintained at a selected potential. At an appropriate potential, an analyte or reaction product undergoes oxidation or reduction, generating a measurable current. Under controlled mass-transfer conditions, the current may be proportional to analyte concentration. In amperometric titration, current is recorded after successive additions of titrant. The shape of the current-versus-volume plot depends on whether the analyte, titrant, or both are electroactive at the selected potential. The equivalence point is often determined from the intersection of linear portions of the titration curve.
Amperometry and Amperometric Titration
Amperometry measures current at a fixed applied potential. Amperometric titration uses changes in current during titrant addition to determine an equivalence point.
Explanation
Variables
| Symbol | Name | Description |
|---|---|---|
I | Current | Rate of electrical charge transfer through a circuit. |
Q | Electrical charge | Total electrical charge transferred during an electrochemical process. |
z | Number of electrons transferred | Number of electrons involved in the balanced electrode reaction. |
F | Faraday constant | Charge per mole of electrons, approximately 96485 C mol⁻¹. |
n | Amount of substance | Amount of a chemical species, expressed in moles. |
c | Analyte concentration | Amount concentration of the electroactive analyte, commonly expressed in mol L⁻¹. |
E | Electrode potential | Electrical potential of an electrode relative to a reference electrode. |
t | Time | Duration of the electrochemical process. |
Example or application
A worked example has not yet been added.
Definition
Amperometry is an electroanalytical technique that measures current at a controlled electrode potential. Amperometric titration determines an endpoint by monitoring current as titrant is added.
Purpose
To quantify electroactive substances and determine titration endpoints using current measurements.
Importance
Amperometry is useful in electrochemical sensors, dissolved oxygen measurements, biochemical analysis, and titrations where a suitable electroactive species is available.
Key Concepts
Applied potential: Controlled potential imposed on the working electrode.
Faradaic current: Current generated by electron-transfer reactions.
Mass transport: Delivery of analyte to the electrode surface.
Limiting current: Current region where further potential change produces little increase in current under the relevant conditions.
Amperometric sensor: Sensor that converts an analyte-dependent electrochemical reaction into a current signal.
Amperometric titration curve: Plot of current against titrant volume.
Three-electrode system: Working, reference, and counter electrodes used to control and measure electrochemical behavior.
Principle
At a selected potential, an electroactive species undergoes an electrode reaction and generates current. Under fixed experimental conditions, the current depends on the concentration of the electroactive species reaching the electrode. During titration, its concentration changes as the reaction proceeds, producing a characteristic current-volume relationship.
Working Process
Identify an electroactive analyte or reaction product suitable for measurement.
Select a potential at which the desired reaction occurs with minimal interference.
Prepare the sample and supporting electrolyte if required.
Set up the working, reference, and counter electrodes.
Allow the background current to stabilize and record an initial measurement.
For direct amperometry, measure the current and use a calibration relationship to determine concentration.
For amperometric titration, add measured portions of titrant while mixing consistently.
Record the current after each addition under comparable conditions.
Plot current against titrant volume and identify the change in slope.
Calculate the analyte amount using the titration stoichiometry.
Equations
| Name | Formula | Meaning |
|---|---|---|
Current | I = dQ/dt | Current is the rate of electrical charge transfer. |
Faraday's law | Q = nFN | Relates total charge to the amount of substance transformed. |
Diffusion-controlled current relationship | I ∝ C | Under fixed potential and controlled experimental conditions, current can be proportional to analyte concentration. |
Units
Current: ampere (A), milliampere (mA), or microampere (µA)
Potential: volt (V)
Charge: coulomb (C)
Amount of substance: mole (mol)
Concentration: mole per litre (mol L⁻¹)
Time: second (s)
Titrant volume: millilitre (mL) or litre (L)
Examples
Determination of dissolved oxygen using an amperometric sensor.
Measurement of glucose using an enzyme-based amperometric biosensor.
Amperometric titration of a suitable electroactive species using a titrant that changes its concentration.
Monitoring an electroactive product formed during a chemical reaction.
Applications
Dissolved oxygen monitoring.
Glucose and other biosensor measurements.
Pharmaceutical analysis.
Environmental monitoring.
Amperometric precipitation and redox titrations.
Industrial process monitoring.
Advantages
Can provide sensitive current measurements.
Suitable for continuous monitoring.
Can be used in small-volume samples.
Does not require a visual indicator for titration endpoints.
Can be incorporated into compact sensors.
Limitations
Interfering electroactive substances can contribute to current.
Electrode fouling can change the response.
Current depends on mass transport and electrode condition.
Applied potential must be selected carefully.
Background current may be significant at low analyte concentrations.
Common Mistakes
Changing the applied potential during a fixed-potential amperometric measurement without accounting for the method.
Ignoring background current.
Failing to control mixing and mass transport during titration.
Assuming current is proportional to concentration under all conditions.
Choosing a potential where interfering substances also react.
Prerequisites
Voltammetry and its basic principles.
Electrode reactions and Faraday's law.
Diffusion and mass transport.
Volumetric titration principles.
Learning Objectives
Define amperometry.
Explain why the applied potential is held constant.
Describe the relationship between current and analyte concentration.
Explain how amperometric titration identifies an equivalence point.
Identify applications and limitations of amperometric methods.
Practice Questions
What is amperometry?
How does amperometry differ from general voltammetry?
Why is a fixed potential selected?
How is the endpoint identified in amperometric titration?
What factors can influence the measured current?
Give three applications of amperometric sensors.
Key Takeaway
Amperometry measures current at a selected potential, allowing analyte concentration or titration progress to be determined from an electrochemical signal.
References
| Title | Type | Url |
|---|---|---|
Bard and Faulkner, Electrochemical Methods: Fundamentals and Applications | textbook | |
Wang, Analytical Electrochemistry | textbook | |
IUPAC Gold Book | terminology reference | https://goldbook.iupac.org/ |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry