When monochromatic radiation passes through a homogeneous absorbing solution under suitable conditions, the absorbance is proportional to the concentration of the absorbing species and the distance travelled through the solution. The law is widely used for quantitative UV–Visible analysis. Absorbance is calculated from the ratio of incident to transmitted radiation. The proportionality constant is the molar absorption coefficient when concentration is expressed in molarity and path length in centimetres. Deviations may occur at high concentrations, with polychromatic radiation, chemical changes, stray light, or instrumental limitations.
Beer–Lambert Law
The Beer–Lambert law describes the relationship between the absorbance of a solution, the concentration of the absorbing species, and the optical path length.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
A | Absorbance | Dimensionless |
ε | Molar absorption coefficient | L mol⁻¹ cm⁻¹ |
l | Optical path length | cm |
c | Concentration of absorbing species | mol L⁻¹ |
I₀ | Incident radiation intensity | Instrument-dependent intensity unit |
I | Transmitted radiation intensity | Same as I₀ |
T | Transmittance | Dimensionless |
Example or application
A worked example has not yet been added.
Definition
The Beer–Lambert law states that the absorbance of a suitable absorbing sample is proportional to the concentration of the absorbing species and the optical path length.
Purpose
To calculate the concentration of absorbing substances from measured absorbance or to determine an absorption coefficient.
Importance
It provides the mathematical foundation for many quantitative absorption measurements, especially UV–Visible spectrophotometry.
Key Concepts
Absorbance
Transmittance
Molar absorption coefficient
Optical path length
Concentration
Monochromatic radiation
Calibration curve
Linear analytical range
Deviations from linearity
Principle
Each absorbing species contributes to the attenuation of radiation. Under appropriate conditions, the total absorbance increases linearly with the concentration of the absorbing species and the path length.
Working Process
Select a wavelength where the analyte absorbs suitably.
Prepare a blank and appropriate calibration standards.
Place the blank in the instrument and establish the reference signal.
Measure the absorbance of the standards using a known path length.
Construct a calibration curve of absorbance against concentration.
Measure the sample absorbance under the same conditions.
Determine the unknown concentration from the calibration relationship.
Equations
| Name | Formula | Description |
|---|---|---|
Beer–Lambert law | A = εlc | Absorbance equals molar absorption coefficient multiplied by path length and concentration. |
Absorbance and transmittance | A = −log₁₀(T) = log₁₀(I₀/I) | Absorbance is the negative base-10 logarithm of transmittance. |
Transmittance | T = I/I₀ | The fraction of incident radiation transmitted through the sample. |
Units
Absorbance: dimensionless
Concentration: mol L⁻¹
Path length: cm
Molar absorption coefficient: L mol⁻¹ cm⁻¹
Transmittance: dimensionless or percentage
Examples
A solution with an absorbance of 0.50 has a transmittance of approximately 0.316.
If ε = 100 L mol⁻¹ cm⁻¹, l = 1 cm, and c = 0.002 mol L⁻¹, then A = 0.20.
A series of standard dye solutions can be used to construct an absorbance-versus-concentration calibration curve.
Applications
Determination of dye concentrations
Measurement of pharmaceutical compounds
Analysis of metal complexes
Quantification of proteins and nucleic acids using suitable assays
Monitoring reaction progress
Advantages
Simple mathematical relationship
Suitable for rapid quantitative measurements
Can provide good precision within a validated linear range
Requires relatively small sample volumes in many instruments
Limitations
The law is not perfectly linear under all concentration conditions
Chemical equilibria can change the concentration of the absorbing species
Turbidity and scattering can affect measured absorbance
Stray light and polychromatic radiation can cause deviations
The sample must be suitable for the selected wavelength and optical system
Common Mistakes
Using percentage transmittance directly as absorbance
Forgetting to use consistent units for path length and concentration
Assuming the law remains linear at every concentration
Ignoring the blank correction
Using an unsuitable wavelength for the analyte
Prerequisites
Absorption spectroscopy
Logarithms
Concentration calculations
Basic UV–Visible spectrophotometry
Learning Objectives
State the Beer–Lambert law
Calculate absorbance from transmittance
Calculate concentration using absorbance and molar absorption coefficient
Explain the role of path length
Identify common causes of deviations from linearity
Practice Questions
State and explain the Beer–Lambert law.
What is the relationship between absorbance and transmittance?
Calculate the absorbance when transmittance is 25%.
A solution has ε = 200 L mol⁻¹ cm⁻¹, l = 1 cm, and A = 0.40. Find its concentration.
List four causes of deviations from the Beer–Lambert law.
Key Takeaway
Under suitable conditions, absorbance is directly proportional to concentration and optical path length, making the Beer–Lambert law fundamental to quantitative absorption spectroscopy.
References
| Title | Type | Url |
|---|---|---|
Skoog, Holler and Crouch, Principles of Instrumental Analysis | textbook | |
Harris, Quantitative Chemical Analysis | textbook | |
IUPAC Gold Book | terminology reference | https://goldbook.iupac.org/ |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry