Quality assurance (QA) consists of planned and systematic activities implemented within a quality system to provide confidence that analytical requirements will be fulfilled. It includes documented procedures, staff competence, method validation, equipment management, training, audits, corrective actions, and continuous improvement. Quality control (QC) consists of operational techniques and activities used to monitor whether analytical processes are performing acceptably. Examples include blanks, replicate measurements, calibration checks, control samples, spike recovery, and certified reference materials. A laboratory quality system combines preventive controls with ongoing monitoring. QC results are evaluated against predefined acceptance criteria, and failures should trigger investigation rather than being ignored or concealed.
Quality Assurance and Quality Control (QA/QC)
Quality assurance and quality control are complementary systems that help laboratories produce reliable, consistent, and technically valid analytical results. QA focuses on the overall quality system, while QC focuses on operational checks of analytical performance.
Explanation
Variables
| Symbol | Name | Description |
|---|---|---|
C_spiked | Spiked sample concentration | The measured concentration after adding a known amount of analyte. |
C_unspiked | Unspiked sample concentration | The measured concentration in the original sample before the spike addition. |
C_added | Added analyte concentration | The concentration contribution from the known spike, expressed on a consistent basis. |
s | Standard deviation | A measure of variability among replicate measurements. |
x̄ | Mean result | The average of the analytical measurements. |
x_reference | Reference value | An accepted value used to evaluate analytical bias. |
a | Calibration intercept | The predicted response when the analyte concentration is zero. |
b | Calibration slope | The change in analytical response per unit change in analyte concentration. |
Example or application
A worked example has not yet been added.
Definition
Quality assurance is the planned and systematic framework used to provide confidence in the quality of analytical work, while quality control is the set of operational checks used to monitor and maintain the quality of individual analytical processes.
Purpose
To ensure that analytical procedures are properly designed, consistently performed, monitored, documented, and capable of producing results that meet specified quality requirements.
Importance
Analytical results may influence research, environmental monitoring, product safety, clinical decisions, and regulatory compliance. A functioning QA/QC system helps laboratories detect problems, maintain consistency, demonstrate competence, and protect the integrity of reported data.
Key Concepts
Quality management system
Quality assurance
Quality control
Standard operating procedures
Method validation
Calibration and verification
Laboratory blanks
Replicate analysis
Certified reference materials
Spike recovery
Control charts
Corrective and preventive action
Document control
Traceability
Principle
Quality is maintained through documented procedures, competent personnel, suitable equipment, verified methods, and continuous monitoring. QA establishes the system that supports reliable work, while QC provides evidence that the analytical process is operating within defined acceptance criteria.
Working Process
Establish quality objectives and define analytical requirements.
Prepare and approve standard operating procedures for laboratory activities.
Train personnel and document their competence.
Maintain, calibrate, and verify analytical instruments.
Validate or verify analytical methods before routine use.
Use appropriate blanks, standards, replicates, and reference materials during analysis.
Evaluate QC results against predefined acceptance criteria.
Investigate deviations and identify root causes when QC results are unacceptable.
Implement corrective actions and assess their effectiveness.
Maintain records, conduct internal audits, and review the quality system.
Equations
Spike recovery (%) = [(C_spiked − C_unspiked) / C_added] × 100
Relative standard deviation (%) = (s / |x̄|) × 100
Measurement bias = x̄ − x_reference
Relative bias (%) = [(x̄ − x_reference) / x_reference] × 100
Calibration response: y = a + bx
Units
Spike recovery: percentage (%)
Relative standard deviation: percentage (%)
Bias: same unit as the analytical measurement
Relative bias: percentage (%)
Concentration: appropriate concentration unit
Calibration response: instrument-dependent unit
Examples
A laboratory analyzes a reagent blank to check whether reagents or laboratory equipment contribute contamination.
A certified reference material is analyzed to assess whether the method produces a result consistent with an established reference value.
A control sample is measured periodically and plotted on a control chart to detect changes in analytical performance.
A known analyte spike is added to a sample to evaluate recovery and possible matrix-related effects.
Applications
Routine chemical analysis
Environmental and water-quality testing
Pharmaceutical quality testing
Food and agricultural analysis
Clinical and biomedical laboratories
Industrial process monitoring
Research and academic laboratories
Advantages
Improves the consistency and reliability of analytical measurements.
Helps identify contamination, calibration problems, and instrument drift.
Provides documented evidence of laboratory performance.
Supports regulatory and accreditation requirements.
Encourages systematic investigation and continuous improvement.
Limitations
Maintaining a quality system requires time, trained personnel, and resources.
QC checks may not detect every source of systematic error.
Poorly selected acceptance limits can produce misleading decisions.
Reference materials may not perfectly represent every sample matrix.
Documentation alone does not guarantee technically valid results.
Common Mistakes
Treating QA and QC as identical activities.
Using QC samples without predefined acceptance criteria.
Ignoring failed control results and continuing analysis without investigation.
Assuming calibration automatically proves method accuracy.
Failing to document corrective actions.
Using reference materials that are unsuitable for the sample matrix or concentration range.
Prerequisites
Basic analytical chemistry
Analytical measurement principles
Calibration
Precision and accuracy
Basic laboratory safety and documentation
Learning Objectives
Differentiate quality assurance and quality control.
Explain the role of a laboratory quality management system.
Describe the use of blanks, replicates, and reference materials.
Explain how spike recovery evaluates analytical performance.
Describe the purpose of control charts.
Explain why corrective actions and documentation are essential.
Practice Questions
What is the difference between QA and QC?
Why are laboratory blanks used?
What information can a certified reference material provide?
How is spike recovery calculated?
What is the purpose of a control chart?
What should a laboratory do when a QC result fails its acceptance criterion?
Why is method validation an important part of quality assurance?
Key Takeaway
QA establishes the overall system for producing reliable analytical results, while QC checks whether the analytical process is performing as required.
References
| Title | Type | Url |
|---|---|---|
ISO/IEC 17025:2017, General Requirements for the Competence of Testing and Calibration Laboratories | international standard | |
Eurachem, The Fitness for Purpose of Analytical Methods | technical guide | |
Harris, Quantitative Chemical Analysis | textbook | |
NIST/SEMATECH e-Handbook of Statistical Methods | technical reference | https://www.itl.nist.gov/div898/handbook/ |
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Analytical Chemistry