A compressor stage is a basic unit of a gas turbine compressor. In an axial compressor, a stage commonly consists of a rotor row followed by a stator row. The rotor adds energy to the airflow, while the stator redirects and diffuses the flow, contributing to a pressure increase. The overall compressor pressure ratio is the ratio of compressor outlet pressure to inlet pressure. Multiple stages are used to obtain the high pressure ratios required by modern gas turbine engines. The overall pressure ratio is the product of the individual stage pressure ratios when the stages are considered in sequence. Stage performance depends on blade geometry, rotational speed, airflow, temperature, and pressure losses. Excessive aerodynamic loading can contribute to compressor stall or surge, which can limit stable compressor operation.
Compressor Stages and Pressure Ratio
A compressor stage is a basic unit of a gas turbine compressor that increases airflow pressure. The overall pressure ratio describes the relationship between compressor outlet and inlet pressures.
Overall pressure ratio = P_out / P_in; Overall pressure ratio = PR_1 × PR_2 × ... × PR_N
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
P_out | Overall compressor outlet pressure | Pa |
P_in | Overall compressor inlet pressure | Pa |
PR_i | Pressure ratio of an individual compressor stage | Dimensionless |
N | Number of compressor stages | Dimensionless |
Example or application
A simplified compressor has three stages, each with a pressure ratio of 1.5. Calculate the overall pressure ratio. Solution: Overall pressure ratio = 1.5 × 1.5 × 1.5 = 3.375. Answer: The overall pressure ratio is 3.375:1.
Key Points
An axial compressor stage includes rotor and stator rows.
Each stage contributes to the total pressure rise.
Overall pressure ratio compares compressor outlet and inlet pressures.
The overall pressure ratio is the product of individual stage pressure ratios.
Stage performance depends on aerodynamic and operating conditions.
Compressor stall and surge can limit operating performance.
Applications
Compressor design
Gas turbine performance analysis
Engine matching
Compressor operating-limit evaluation
Common Mistakes
Adding individual stage pressure ratios instead of multiplying them.
Assuming every stage has an identical pressure ratio in a real compressor.
Treating compressor stall and surge as exactly the same phenomenon.
Learning Outcomes
Define a compressor stage.
Explain how multiple stages increase overall pressure.
Calculate overall pressure ratio from inlet and outlet pressures.
Explain how individual stage pressure ratios combine.
Practice Questions
| Question | Answer |
|---|---|
What components commonly form an axial compressor stage? | A rotor row followed by a stator row. |
Two idealized compressor stages each have a pressure ratio of 2. What is their combined pressure ratio? | 2 × 2 = 4. |
Related Concepts
Axial Flow Compressors
Centrifugal Flow Compressors
Gas Turbine Engine Architecture
Compressor Stall and Surge
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Gas Turbine Theory, H. I. H. Saravanamuttoo and collaborators
- FAA – Aviation Maintenance Technician Handbook: Powerplant
Suggest a correction or source · More in Aerospace Engineering