✦ScienexySCIENCE KNOWLEDGE LIBRARY
topic · SCI-PHY-017-019

SI Units of Magnetic Quantities

Magnetic quantities are measured using standard SI units. Important examples include tesla for magnetic flux density, weber for magnetic flux, ampere per metre for magnetic field intensity and magnetization, and ampere square metre for magnetic dipole moment.

Explanation

The International System of Units provides standard units for measuring magnetic quantities. Magnetic flux density, represented by B, is measured in tesla (T). Magnetic flux, represented by ΦB, is measured in weber (Wb). Magnetic field intensity, represented by H, is measured in amperes per metre (A/m). Magnetization, represented by M, is also measured in amperes per metre. Magnetic dipole moment, represented by m, is measured in ampere square metres (A m²). Magnetic permeability, represented by μ, is measured in henries per metre (H/m), which is equivalent to newtons per ampere squared (N/A²). The magnetic field quantities B and H are related but are not interchangeable. In vacuum, B = μ0H, where μ0 is the vacuum permeability. In a linear, isotropic material, a simplified relation is B = μH. These units are important in physics calculations, engineering design, scientific measurements, and electromagnetic technology.

Example or application

A magnetic flux density of 0.5 T means that the magnetic flux density has a magnitude of half a tesla.

Definition

SI units of magnetic quantities are the internationally standardized units used to measure magnetic fields, flux, magnetization, magnetic moments, and related properties.

Purpose

Standard units make magnetic measurements consistent, comparable, and suitable for scientific calculations and engineering applications.

Importance

Correct units are essential for calculating magnetic forces, magnetic flux, magnetic fields, magnetic moments, and the behavior of magnetic materials.

Magnetic Quantities

QuantitySymbolSi UnitUnit SymbolEquivalent UnitDescription

Magnetic flux density

B

tesla

T

Wb/m² or N/(A m)

Describes the magnetic field's flux density and appears in magnetic-force and flux calculations.

Magnetic flux

ΦB

weber

Wb

T m² or V s

Measures the net magnetic field passing through a surface.

Magnetic field intensity

H

ampere per metre

A/m

A m⁻¹

Describes the magnetic field intensity associated with free currents and material response.

Magnetization

M

ampere per metre

A/m

A m⁻¹

Measures the magnetic dipole moment per unit volume of a material.

Magnetic dipole moment

m

ampere square metre

A m²

A m²

Measures the strength and orientation of a magnetic dipole.

Magnetic permeability

μ

henry per metre

H/m

N/A²

Describes a material's response in the relationship between B and H.

Vacuum permeability

μ0

henry per metre

H/m

The permeability constant of vacuum in the SI electromagnetic framework.

Magnetic susceptibility

χ

dimensionless

1

Measures the response of magnetization to an applied magnetic field under a specified convention.

Important Unit Conversions

RelationshipMeaning

1 Wb = 1 T m²

One weber is equal to one tesla multiplied by one square metre.

1 T = 1 Wb/m²

One tesla is one weber of magnetic flux per square metre.

1 T = 1 N/(A m)

One tesla is equivalent to one newton per ampere metre.

1 Wb = 1 V s

One weber is equal to one volt-second.

Important Relations

EquationMeaning

ΦB = B A cos(theta)

Magnetic flux through a flat surface in a uniform magnetic field.

F = q(v × B)

Magnetic force on a moving point charge.

F = I(L × B)

Magnetic force on a straight current-carrying conductor in a uniform field.

m = N I A

Magnetic dipole moment of a planar coil.

B = μ0 H

Relationship between magnetic flux density and magnetic field intensity in vacuum.

Distinction Between BAnd H

B

Magnetic flux density, measured in tesla, describes the magnetic field that appears in the Lorentz force and magnetic flux equations.

H

Magnetic field intensity, measured in A/m, is useful for describing the magnetic field associated with free currents and separating material response.

Important Note

B and H are different physical quantities, even though they are related.

Vacuum Permeability

Symbol

μ0

Description

The magnetic permeability of vacuum.

Unit

H/m

Note

In the revised SI, μ0 is experimentally determined rather than having the exact defining value it had in the previous SI.

Dimensional Analysis

QuantityDimensionDescription

Magnetic flux density

M T⁻² I⁻¹

Dimension of magnetic flux density in terms of mass, time, and electric current.

Magnetic flux

M L² T⁻² I⁻¹

Dimension of magnetic flux.

Magnetic dipole moment

I L²

Dimension of magnetic dipole moment.

Common Misconceptions

  • Tesla and weber measure different magnetic quantities: tesla measures magnetic flux density, while weber measures magnetic flux.

  • Magnetic field intensity H and magnetic flux density B are not the same quantity.

  • Magnetization M is measured in A/m, not tesla.

  • Magnetic susceptibility is dimensionless in the usual SI convention for linear susceptibility.

  • The unit of magnetic dipole moment is A m², not A/m.

Learning Objectives

  • Identify the SI units of major magnetic quantities.

  • Distinguish magnetic flux density from magnetic flux.

  • Differentiate B from H.

  • State the SI unit of magnetic dipole moment.

  • Use common unit conversions.

  • Apply dimensional analysis to magnetic equations.

Key Takeaway

Using the correct SI unit is essential: magnetic flux density is measured in tesla, magnetic flux in weber, and magnetic dipole moment in ampere square metres.

Related Topics

  • SCI-PHY-017-011

  • SCI-PHY-017-013

  • SCI-PHY-017-018

  • SCI-PHY-017-020

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

Suggest a correction or source · More in Magnetism & Electromagnetism