✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-002-015

Luminous Efficacy of Monochromatic Radiation (Kcd)

The luminous efficacy of monochromatic radiation is the exact SI defining constant that connects optical radiation at a specified frequency to the photometric quantity of luminous intensity. It establishes the relationship between radiometric power and the human visual response used in the SI definition of the candela.

Kcd = 683 lm·W⁻¹ (exact), at ν = 540 × 10¹² Hz. At the reference frequency, luminous flux Φv = Kcd × Φe, where Φe is radiant flux.

Explanation

The luminous efficacy constant Kcd is fixed at exactly 683 lumens per watt for monochromatic radiation of frequency 540 × 10¹² Hz. It is part of the definition of the candela, the SI base unit of luminous intensity. Radiometry measures electromagnetic radiation in physical energy units, such as watts, whereas photometry weights optical radiation according to the standardized spectral luminous efficiency function for human vision under specified photopic viewing conditions. The reference frequency of 540 THz corresponds approximately to green light with a wavelength near 555 nm in standard air, although the defining quantity is frequency, not an approximate wavelength. The constant provides the exact reference point that links radiometric and photometric measurements. It does not imply that all wavelengths produce the same perceived brightness for the same radiant power; the visual response varies with wavelength.

Variables

SymbolMeaningSi UnitValue

Kcd

Luminous efficacy constant for the SI definition of the candela

lm·W⁻¹

683 (exact)

ν

Frequency of monochromatic radiation

Hz

540 × 10¹² Hz (reference frequency)

Φv

Luminous flux

lm

Φe

Radiant flux

W

Example or application

A worked example has not yet been added.

Definition

The luminous efficacy constant Kcd is the exact proportionality value of 683 lm·W⁻¹ assigned to monochromatic radiation of frequency 540 × 10¹² Hz in the SI definition of the candela.

Purpose

To establish the exact radiometric-to-photometric reference used in defining the SI candela and to connect physical optical power with standardized visual weighting.

Importance

The constant is essential for photometric standards, lighting measurements, display characterization, optical instrumentation, and the traceability of luminous-intensity measurements to the SI.

Relationship To SI

The candela is defined by fixing Kcd at 683 lm·W⁻¹ for monochromatic radiation of frequency 540 × 10¹² Hz. This definition also relies on the SI definitions of the metre, kilogram, and second through the watt and the radiometric quantities.

Exactness And Measurement

The value 683 lm·W⁻¹ at the specified frequency is exact by definition. Practical photometric measurements have uncertainty because of detector calibration, spectral response, geometry, source stability, and measurement conditions.

Radiometry And Photometry

Radiometry measures optical radiation in physical energy terms, while photometry weights radiation according to the standardized human visual sensitivity function. At frequencies other than the defining reference frequency, the spectral luminous efficacy depends on the photopic luminous efficiency function V(λ).

Spectral Dependence

The constant Kcd is not a universal conversion factor of 683 lm per watt for every wavelength. For monochromatic radiation at other visible wavelengths, the corresponding photometric conversion is weighted by the standardized spectral luminous efficiency function. Radiation outside the visible range contributes negligibly or not at all to photopic luminous flux under the standard function.

Worked Example

At the reference frequency, 2 W of monochromatic radiant flux corresponds to Φv = 683 × 2 = 1,366 lm under the defining photometric relationship.

Applications

  • SI realization of the candela

  • Calibration of photometric instruments

  • Lighting and lamp performance measurements

  • Display and screen brightness characterization

  • Optical detector and sensor calibration

  • Photometry and radiometry research

Common Misconceptions

  • The value 683 lm·W⁻¹ applies exactly at the specified reference frequency, not uniformly across all wavelengths.

  • Luminous flux and radiant flux are different quantities; one is photometrically weighted and the other measures physical radiant power.

  • The constant is based on standardized photopic visual response, not an individual's subjective perception.

  • The defining constant does not eliminate uncertainty from practical light measurements.

Related Topics

  • Candela

  • Luminous intensity

  • Luminous flux

  • Radiant flux

  • Photometry

  • Radiometry

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • BIPM — The International System of Units (SI Brochure), 9th edition
  • CIE — The Basis of Physical Photometry
  • NIST — Photometric and Radiometric Measurements

Suggest a correction or source · More in Physical Constants