✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-002-078

Magnetic Susceptibility and Relative Permeability

Magnetic susceptibility and relative permeability describe how materials respond to applied magnetic fields. Susceptibility quantifies the magnetization induced by a magnetic field, while relative permeability compares a material's magnetic permeability with that of vacuum.

M = χₘH; μᵣ = μ/μ₀

Explanation

When a material is placed in a magnetic field, its internal magnetic moments and electronic structure respond to the applied field. The resulting magnetization depends on the material's magnetic properties. Magnetic susceptibility describes the proportional relationship between magnetization and magnetic field intensity in a linear material. Relative permeability compares the material's magnetic permeability with vacuum permeability. Different classes of materials exhibit distinct magnetic responses. Diamagnetic materials develop a weak magnetization opposing the applied field. Paramagnetic materials develop a weak magnetization in the direction of the field. Ferromagnetic materials can develop strong magnetization because of collective ordering of magnetic moments and magnetic-domain behaviour. Antiferromagnetic and ferrimagnetic materials exhibit additional ordering patterns. In real materials, magnetic response may be nonlinear, anisotropic, frequency-dependent, and history-dependent. Ferromagnetic materials often show hysteresis, meaning that magnetization depends on previous magnetic-field conditions.

Variables

SymbolMeaningUnitValue

M

Magnetization, magnetic dipole moment per unit volume

A·m⁻¹

χₘ

Volume magnetic susceptibility in the SI convention

Dimensionless

H

Magnetic field strength

A·m⁻¹

μᵣ

Relative magnetic permeability

Dimensionless

μ

Magnetic permeability of the material

H·m⁻¹

μ₀

Vacuum magnetic permeability

H·m⁻¹

Approximately 1.2566370613 × 10⁻⁶

Example or application

A worked example has not yet been added.

Definition

Magnetic susceptibility measures the response of material magnetization to an applied magnetic field, while relative permeability is the ratio of material permeability to vacuum permeability.

Purpose

To characterize magnetic response and determine how a material changes the magnetic field within and around it.

Importance

These properties are important in electromagnets, transformers, motors, magnetic sensors, inductors, magnetic storage, shielding, medical imaging, and the design of magnetic materials.

Magnetic Material Classes

ClassDescription

Diamagnetic

Develops a weak magnetization opposing the applied field. Its volume susceptibility is generally small and negative.

Paramagnetic

Develops a weak magnetization in the direction of the applied field. Its susceptibility is generally positive and often temperature-dependent.

Ferromagnetic

Can exhibit strong spontaneous magnetization, magnetic domains, nonlinear response, and hysteresis.

Antiferromagnetic

Neighbouring magnetic moments tend to align antiparallel, producing little or no net magnetization in the ideal ordered state.

Ferrimagnetic

Magnetic sublattices align antiparallel but have unequal moments, producing a net magnetization.

Constitutive Relations

Description

For a linear, isotropic magnetic material under the conventional SI macroscopic description:

Relationships

  • B = μ₀(H + M)

  • B = μH

  • μᵣ = 1 + χₘ

Note

The relation μᵣ = 1 + χₘ applies to a linear, isotropic material with the stated SI definitions. It is not a general description of nonlinear ferromagnets or all anisotropic media.

Typical Magnetic Behaviour

Material ClassSusceptibility BehaviourExamples

Diamagnetic substances

Small negative susceptibility

Copper, bismuth, graphite, and water

Paramagnetic substances

Small positive susceptibility

Aluminium, oxygen, and many transition-metal salts

Ferromagnetic substances

Strongly field-dependent response

Iron, cobalt, and nickel under suitable conditions

Ferrimagnetic substances

Strong magnetic response with unequal opposing sublattice moments

Many ferrites and magnetite

Frequency And Field Dependence

  • Magnetic response can vary with frequency because magnetic moments and domain structures respond on different timescales.

  • Ferromagnetic materials can exhibit saturation when increasing field strength produces progressively smaller additional magnetization.

  • Hysteresis causes the magnetic response to depend on previous magnetic-field conditions.

  • Magnetic anisotropy makes susceptibility and permeability dependent on field direction in many crystals and engineered materials.

Worked Example

Problem

A linear isotropic material has volume magnetic susceptibility χₘ = 0.002. Calculate its relative permeability using the linear SI relation.

Solution

  • Use μᵣ = 1 + χₘ.

  • μᵣ = 1 + 0.002.

  • μᵣ = 1.002.

Answer

The relative permeability is 1.002.

Measurement Methods

  • A vibrating-sample magnetometer measures magnetic moment as a function of applied field.

  • A superconducting quantum interference device magnetometer can measure very small magnetic responses.

  • Induction and permeability instruments characterize magnetic response under specified frequencies and field strengths.

  • Gouy and Faraday balance methods can determine magnetic susceptibility for suitable samples.

Conditions And Limitations

  • Susceptibility and permeability depend on temperature, field strength, frequency, sample shape, and magnetic history.

  • The relation μᵣ = 1 + χₘ assumes a linear, isotropic material under the standard SI convention.

  • Ferromagnetic materials generally require nonlinear constitutive relationships and may show hysteresis.

  • Anisotropic materials require tensor descriptions.

  • Magnetic measurements can be influenced by demagnetizing fields and specimen geometry.

Common Misconceptions

  • Relative permeability and magnetic susceptibility are related but are not the same quantity.

  • A relative permeability greater than one does not by itself identify a material as ferromagnetic.

  • The permeability of a ferromagnetic material is not generally a single constant valid at every field strength.

  • Magnetic susceptibility is dimensionless in the standard SI volume convention, but mass-specific and molar susceptibilities use different units.

Related Topics

  • Vacuum Magnetic Permeability

  • Dielectric Constants and Relative Permittivity

  • Electrical Resistivity and Conductivity

  • Magnetic Materials

  • Electromagnetic Waves

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Griffiths — Introduction to Electrodynamics.
  • Kittel — Introduction to Solid State Physics.
  • Cullity and Graham — Introduction to Magnetic Materials.

Suggest a correction or source · More in Physical Constants