When a material is placed in a magnetic field, its internal magnetic moments and electronic structure respond to the applied field. The resulting magnetization depends on the material's magnetic properties. Magnetic susceptibility describes the proportional relationship between magnetization and magnetic field intensity in a linear material. Relative permeability compares the material's magnetic permeability with vacuum permeability. Different classes of materials exhibit distinct magnetic responses. Diamagnetic materials develop a weak magnetization opposing the applied field. Paramagnetic materials develop a weak magnetization in the direction of the field. Ferromagnetic materials can develop strong magnetization because of collective ordering of magnetic moments and magnetic-domain behaviour. Antiferromagnetic and ferrimagnetic materials exhibit additional ordering patterns. In real materials, magnetic response may be nonlinear, anisotropic, frequency-dependent, and history-dependent. Ferromagnetic materials often show hysteresis, meaning that magnetization depends on previous magnetic-field conditions.
Magnetic Susceptibility and Relative Permeability
Magnetic susceptibility and relative permeability describe how materials respond to applied magnetic fields. Susceptibility quantifies the magnetization induced by a magnetic field, while relative permeability compares a material's magnetic permeability with that of vacuum.
M = χₘH; μᵣ = μ/μ₀
Explanation
Variables
| Symbol | Meaning | Unit | Value |
|---|---|---|---|
M | Magnetization, magnetic dipole moment per unit volume | A·m⁻¹ | |
χₘ | Volume magnetic susceptibility in the SI convention | Dimensionless | |
H | Magnetic field strength | A·m⁻¹ | |
μᵣ | Relative magnetic permeability | Dimensionless | |
μ | Magnetic permeability of the material | H·m⁻¹ | |
μ₀ | Vacuum magnetic permeability | H·m⁻¹ | Approximately 1.2566370613 × 10⁻⁶ |
Example or application
A worked example has not yet been added.
Definition
Magnetic susceptibility measures the response of material magnetization to an applied magnetic field, while relative permeability is the ratio of material permeability to vacuum permeability.
Purpose
To characterize magnetic response and determine how a material changes the magnetic field within and around it.
Importance
These properties are important in electromagnets, transformers, motors, magnetic sensors, inductors, magnetic storage, shielding, medical imaging, and the design of magnetic materials.
Magnetic Material Classes
| Class | Description |
|---|---|
Diamagnetic | Develops a weak magnetization opposing the applied field. Its volume susceptibility is generally small and negative. |
Paramagnetic | Develops a weak magnetization in the direction of the applied field. Its susceptibility is generally positive and often temperature-dependent. |
Ferromagnetic | Can exhibit strong spontaneous magnetization, magnetic domains, nonlinear response, and hysteresis. |
Antiferromagnetic | Neighbouring magnetic moments tend to align antiparallel, producing little or no net magnetization in the ideal ordered state. |
Ferrimagnetic | Magnetic sublattices align antiparallel but have unequal moments, producing a net magnetization. |
Constitutive Relations
Description
For a linear, isotropic magnetic material under the conventional SI macroscopic description:
Relationships
B = μ₀(H + M)
B = μH
μᵣ = 1 + χₘ
Note
The relation μᵣ = 1 + χₘ applies to a linear, isotropic material with the stated SI definitions. It is not a general description of nonlinear ferromagnets or all anisotropic media.
Typical Magnetic Behaviour
| Material Class | Susceptibility Behaviour | Examples |
|---|---|---|
Diamagnetic substances | Small negative susceptibility | Copper, bismuth, graphite, and water |
Paramagnetic substances | Small positive susceptibility | Aluminium, oxygen, and many transition-metal salts |
Ferromagnetic substances | Strongly field-dependent response | Iron, cobalt, and nickel under suitable conditions |
Ferrimagnetic substances | Strong magnetic response with unequal opposing sublattice moments | Many ferrites and magnetite |
Frequency And Field Dependence
Magnetic response can vary with frequency because magnetic moments and domain structures respond on different timescales.
Ferromagnetic materials can exhibit saturation when increasing field strength produces progressively smaller additional magnetization.
Hysteresis causes the magnetic response to depend on previous magnetic-field conditions.
Magnetic anisotropy makes susceptibility and permeability dependent on field direction in many crystals and engineered materials.
Worked Example
Problem
A linear isotropic material has volume magnetic susceptibility χₘ = 0.002. Calculate its relative permeability using the linear SI relation.
Solution
Use μᵣ = 1 + χₘ.
μᵣ = 1 + 0.002.
μᵣ = 1.002.
Answer
The relative permeability is 1.002.
Measurement Methods
A vibrating-sample magnetometer measures magnetic moment as a function of applied field.
A superconducting quantum interference device magnetometer can measure very small magnetic responses.
Induction and permeability instruments characterize magnetic response under specified frequencies and field strengths.
Gouy and Faraday balance methods can determine magnetic susceptibility for suitable samples.
Conditions And Limitations
Susceptibility and permeability depend on temperature, field strength, frequency, sample shape, and magnetic history.
The relation μᵣ = 1 + χₘ assumes a linear, isotropic material under the standard SI convention.
Ferromagnetic materials generally require nonlinear constitutive relationships and may show hysteresis.
Anisotropic materials require tensor descriptions.
Magnetic measurements can be influenced by demagnetizing fields and specimen geometry.
Common Misconceptions
Relative permeability and magnetic susceptibility are related but are not the same quantity.
A relative permeability greater than one does not by itself identify a material as ferromagnetic.
The permeability of a ferromagnetic material is not generally a single constant valid at every field strength.
Magnetic susceptibility is dimensionless in the standard SI volume convention, but mass-specific and molar susceptibilities use different units.
Related Topics
Vacuum Magnetic Permeability
Dielectric Constants and Relative Permittivity
Electrical Resistivity and Conductivity
Magnetic Materials
Electromagnetic Waves
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Griffiths — Introduction to Electrodynamics.
- Kittel — Introduction to Solid State Physics.
- Cullity and Graham — Introduction to Magnetic Materials.