✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-002-088

CODATA Recommended Values of Fundamental Physical Constants

CODATA recommended values are internationally recognized reference values for fundamental physical constants, produced through critical evaluation and adjustment of experimental and theoretical data. They provide consistent numerical values, uncertainties and correlations for scientific calculations and precision research.

For a constant represented by q, a recommended result is commonly expressed as:

q = q₀ ± u(q)

where q₀ is the recommended value and u(q) is its standard uncertainty.

For a set of correlated constants, the adjustment also provides covariance information:

Cov(qᵢ, qⱼ) = rᵢⱼ u(qᵢ)u(qⱼ)

where rᵢⱼ is the correlation coefficient between the two adjusted quantities.

Explanation

The Committee on Data of the International Science Council (CODATA) supports the international organization and evaluation of scientific data. Its Task Group on Fundamental Constants coordinates the adjustment of recommended values for fundamental physical constants.

The CODATA adjustment combines relevant experimental measurements, theoretical relationships and uncertainty information to produce a self-consistent set of recommended values. It is not simply an arithmetic average of published measurements. Different experiments may measure related quantities, and theoretical equations may connect several constants. A global adjustment accounts for these relationships and the reliability of the available data.

A CODATA recommended value generally includes a numerical estimate, an associated standard uncertainty, a unit and sometimes a relative uncertainty. The uncertainty describes the evaluated degree of knowledge of the quantity based on the available evidence and adjustment framework.

Examples of fundamental constants included in CODATA datasets are the Newtonian gravitational constant G, Planck constant h, reduced Planck constant ℏ, elementary charge e, electron mass me, proton mass mp, fine-structure constant α, Rydberg constant R∞ and Boltzmann constant kB.

Some constants have exact values in the modern SI because their numerical values are fixed by definition. For example, h, e and kB are exact in SI units. Other constants remain experimentally determined and have uncertainties. The Newtonian gravitational constant is one example of a quantity that is still measured experimentally with comparatively substantial relative uncertainty.

CODATA adjustments are updated as new measurements and improved theoretical calculations become available. Consequently, values from different CODATA editions may differ slightly. Scientific publications should identify the edition or adjustment year used, especially when high precision is required.

A recommended value is not necessarily the result of one experiment. It represents an evaluated result based on a network of measurements and physical relationships. The adjustment process can also reveal inconsistencies among measurements, identify influential experiments and indicate where further experimental work is needed.

CODATA values are widely used in physics, chemistry, astronomy, engineering, spectroscopy, quantum science and precision metrology. They provide a common reference so that researchers do not unknowingly use incompatible values from different sources.

Variables

SymbolMeaningSi Unit

q₀

Recommended numerical estimate of a physical constant

Depends on the constant

u(q)

Standard uncertainty associated with the recommended value

Same as q

rᵢⱼ

Correlation coefficient between two adjusted quantities

Dimensionless

Cov(qᵢ, qⱼ)

Covariance between two adjusted quantities

Product of the units of qᵢ and qⱼ

Example or application

A worked example has not yet been added.

Definition

CODATA recommended values are critically evaluated numerical estimates of fundamental physical constants, accompanied by uncertainty information and produced through internationally coordinated data evaluation and adjustment.

Purpose

To provide a scientifically evaluated and internally consistent reference set of fundamental constants for calculations, experimental analysis and international scientific communication.

Importance

CODATA recommendations reduce inconsistencies caused by using unrelated published measurements. They are particularly important in precision experiments where small differences in constant values can affect theoretical predictions, uncertainty budgets and comparisons between laboratories.

Evaluation Process

  • Data collection: identify relevant experimental measurements, theoretical results and published evaluations.

  • Data assessment: examine experimental methods, uncertainty budgets, systematic effects and reliability.

  • Relationship analysis: identify theoretical equations connecting measured quantities and constants.

  • Statistical adjustment: combine the accepted data using an appropriate least-squares adjustment and uncertainty model.

  • Consistency examination: investigate residuals, disagreements and correlations among the input data.

  • Recommendation: publish adjusted values, uncertainties, correlations and supporting documentation.

Types Of Reference Values

TypeDescription

Exact defining values

Numerical values fixed by the SI definitions. Their SI numerical values have zero uncertainty by definition.

Adjusted experimental values

Values obtained from evaluated experimental information and physical relationships, with associated uncertainties.

Derived values

Values calculated from other constants using theoretical or mathematical relationships. Their uncertainties depend on the input uncertainties and correlations.

Conventional values

Values adopted for particular practical purposes or conventions. They must not be confused with newly measured fundamental constants.

Exact And Uncertain Constants

The modern SI fixes the numerical values of several constants, including c, h, e, kB and NA. Their exactness follows from the definitions of the units. In contrast, G is determined experimentally and has a nonzero uncertainty. A CODATA dataset may include both exact defining constants and experimentally adjusted quantities, but their uncertainty status must be interpreted correctly.

Understanding Uncertainty

A recommended value written as q = 1.2345 ± 0.0006 indicates an estimate of 1.2345 with standard uncertainty 0.0006, provided the uncertainty convention is stated. The uncertainty is not automatically a guaranteed maximum error or a complete interval containing the true value. Its interpretation depends on the statistical model and coverage convention.

Correlations And Consistency

Physical constants are often related by theoretical equations. For example, several electromagnetic constants are connected through the speed of light, vacuum permittivity and vacuum permeability. When multiple constants are adjusted together, their uncertainties may be correlated. Treating correlated values as statistically independent can produce incorrect uncertainty estimates in later calculations.

Worked Example

Problem

A reference table gives a hypothetical constant as q = (2.500 ± 0.004) × 10⁻⁶ in SI units. Calculate its relative standard uncertainty.

Solution

  • The recommended value is q = 2.500 × 10⁻⁶.

  • The standard uncertainty is u(q) = 0.004 × 10⁻⁶.

  • Relative standard uncertainty = u(q)/|q|.

  • Relative standard uncertainty = 0.004/2.500 = 0.0016.

  • As a percentage, 0.0016 × 100 = 0.16%.

Result

Relative standard uncertainty = 0.0016 = 0.16%. This is an illustrative calculation, not an actual CODATA recommendation.

Using Codata Data Correctly

  • Identify the CODATA adjustment year or edition.

  • Record the complete numerical value and unit.

  • Record the standard uncertainty and relative uncertainty when available.

  • Check whether the quantity is exact by SI definition or experimentally determined.

  • Use the published correlation information when combining related constants.

  • Preserve sufficient significant digits during intermediate calculations.

  • Cite the specific CODATA publication or database version in research.

Common Misconceptions

  • CODATA values are not necessarily direct measurements from a single laboratory.

  • The latest recommended value is not automatically more accurate in every practical application; the relevant uncertainty and measurement context matter.

  • Exact SI defining constants do not have experimentally estimated uncertainty in their assigned numerical values.

  • A recommended value and its uncertainty should not be separated when reporting precision results.

  • Different editions may contain revised values because of new data, improved methods or changes in the evaluation.

Limitations And Considerations

  • A recommended value depends on the quality and completeness of the data available at the time of adjustment.

  • Undetected systematic errors in input experiments can affect an adjustment.

  • The adjustment depends on the validity of the theoretical relationships used.

  • Correlations among constants must be considered in precision calculations.

  • Users should not mix values from different editions without checking consistency.

Applications

  • Precision tests of quantum electrodynamics and other physical theories.

  • Atomic and molecular spectroscopy.

  • Determination of particle properties.

  • Fundamental metrology and realization of measurement standards.

  • Precision calculations in chemistry and condensed-matter physics.

  • Comparison of experimental results with theoretical predictions.

Related Topics

  • SCI-REF-002-001

  • SCI-REF-002-007

  • SCI-REF-002-087

  • SCI-REF-002-089

  • SCI-REF-002-090

  • SCI-REF-002-092

  • SCI-REF-002-095

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • CODATA Task Group on Fundamental Constants — Recommended Values of the Fundamental Physical Constants.
  • NIST — Fundamental Physical Constants.
  • BIPM — The International System of Units (SI Brochure), 9th edition.

Suggest a correction or source · More in Physical Constants