Historical Development
Early Standards
Before international standardization, luminous intensity was compared using flame-based and other practical light sources, which were difficult to reproduce consistently.
International Candela
The candela was adopted as an SI base unit in 1979, using a definition based on monochromatic radiation at a specified frequency and a fixed luminous efficacy.
Modern SI
The revised SI retained the same essential photometric definition, expressed through the exact fixed value of 683 lm W⁻¹ for radiation at 540 × 10¹² Hz.
Modern Definition
Official Definition
The candela, symbol cd, is the SI unit of luminous intensity in a given direction. It is defined by taking the fixed numerical value of the luminous efficacy Kcd of monochromatic radiation of frequency 540 × 10¹² Hz to be 683 when expressed in lm W⁻¹, which is equal to cd sr W⁻¹, or cd sr kg⁻¹ m⁻² s³, where the kilogram, metre and second are defined in terms of h, c and ΔνCs.
Defining Constant
Kcd = 683 lm W⁻¹ exactly at a frequency of 540 × 10¹² Hz.
Meaning
The definition establishes a precise relationship between radiant power and the corresponding photometric quantity for radiation at the specified frequency.
Visual Condition
The photometric definition is based on the standardized spectral luminous efficiency function for photopic, or daylight-adapted, human vision.
Physical Meaning
Luminous Intensity
Luminous intensity describes the luminous flux emitted per unit solid angle in a specified direction.
Photometry
Photometry measures optical radiation according to the standardized spectral sensitivity of human vision under specified viewing conditions.
Radiometry
Radiometry measures electromagnetic radiation in physical energy terms without weighting it according to human visual sensitivity.
Dimension
The candela is an SI base unit, but its dimensional representation in terms of the other base dimensions is commonly written as J, where J is the symbol for luminous intensity in dimensional analysis.
Photometric And Radiometric Quantities
Luminous Flux
Luminous flux is the rate of flow of visually weighted light and is measured in lumens (lm).
Luminous Intensity
Luminous intensity is luminous flux per unit solid angle and is measured in candelas (cd).
Illuminance
Illuminance is luminous flux incident per unit area and is measured in lux (lx), where 1 lx = 1 lm m⁻².
Luminance
Luminance describes luminous intensity per projected area in a specified direction and is measured in cd m⁻².
Radiant Flux
Radiant flux is optical or electromagnetic radiant power and is measured in watts (W).
Solid Angle
Solid angle is measured in steradians (sr). The steradian is a dimensionless derived SI unit with a special name.
Human Visual Response
Photopic Vision
Photopic vision refers to daylight-adapted vision, dominated by cone photoreceptors. The standardized photopic luminous efficiency function V(λ) describes the relative sensitivity of the average human observer under defined conditions.
Maximum Sensitivity
The photopic luminous efficiency function reaches its maximum at approximately 555 nm, corresponding to a frequency close to 540 × 10¹² Hz in vacuum.
Scotopic Vision
Scotopic vision refers to low-light vision dominated by rod photoreceptors. It has a different spectral sensitivity and is not the basis of the candela's defining frequency.
Mesopic Vision
Mesopic vision occurs between photopic and scotopic conditions and involves both rods and cones.
Important Clarification
The candela is a standardized photometric unit, not a direct measure of the total physical energy emitted by a light source.
Realization And Measurement
Radiometric Approach
A practical realization can use a calibrated radiometric source or detector and apply the standardized spectral luminous efficiency function to obtain photometric quantities.
Spectral Measurements
Spectroradiometers measure optical power as a function of wavelength. The measured spectrum can be weighted by V(λ) to determine photometric quantities.
Detector Based Methods
Photometric detectors are designed or corrected to approximate the standardized photopic response, and their calibration is traceable to radiometric standards.
Goniophotometry
A goniophotometer measures the angular distribution of luminous intensity from a source.
Environmental Factors
Stray light, detector spectral mismatch, temperature, source stability, alignment and measurement geometry can affect results.
Applications
Lighting design and architectural illumination.
Automotive headlights and signal lights.
Display and screen brightness measurement.
Street lighting and workplace illumination.
Photographic and cinematographic lighting.
Optical instrument calibration.
Vision research and lighting standards.
Limitations And Considerations
Luminous intensity is directional; a source may have different values in different directions.
Photometric values depend on the standardized human visual response, while radiometric values describe physical radiation.
The candela's definition is based on photopic vision and does not directly describe all low-light visual conditions.
A lamp's electrical power in watts is not the same as its luminous flux in lumens.
Measurement geometry and spectral distribution must be considered when comparing light sources.
Common Misconceptions
Candela is not a unit of total light output; lumen measures luminous flux.
Lux measures illuminance, not luminous intensity.
The watt measures radiant or electrical power, not perceived brightness.
The candela is not defined by a candle flame in the modern SI.
The specified 540 THz frequency is not the only frequency at which photometric quantities can be measured; it is the frequency used in the definition.