✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-003-027

Candela (cd): Unit of Luminous Intensity

The candela (cd) is the SI base unit of luminous intensity in a given direction. It is defined by fixing the numerical value of the luminous efficacy of monochromatic radiation of frequency 540 × 10¹² Hz to exactly 683 when expressed in lumens per watt. The candela connects physical optical radiation to human visual sensitivity under defined photopic vision conditions and provides the foundation for photometric measurements.

Defining Constant

Kcd = 683 lm W⁻¹ exactly at 540 × 10¹² Hz

Luminous Intensity

Iv = dΦv/dΩ

Illuminance

Ev = dΦv/dA

Luminance

Lv = d²Φv/(dA cos θ dΩ)

Spectral Weighting

Φv = 683 lm W⁻¹ × ∫ V(λ) Φe,λ dλ

Dimensional Representation

[Iv] = J

Notes

The spectral weighting expression assumes consistent wavelength and spectral radiant-flux conventions. The photometric quantities use standardized visual weighting.

Explanation

Historical Development

Early Standards

Before international standardization, luminous intensity was compared using flame-based and other practical light sources, which were difficult to reproduce consistently.

International Candela

The candela was adopted as an SI base unit in 1979, using a definition based on monochromatic radiation at a specified frequency and a fixed luminous efficacy.

Modern SI

The revised SI retained the same essential photometric definition, expressed through the exact fixed value of 683 lm W⁻¹ for radiation at 540 × 10¹² Hz.

Modern Definition

Official Definition

The candela, symbol cd, is the SI unit of luminous intensity in a given direction. It is defined by taking the fixed numerical value of the luminous efficacy Kcd of monochromatic radiation of frequency 540 × 10¹² Hz to be 683 when expressed in lm W⁻¹, which is equal to cd sr W⁻¹, or cd sr kg⁻¹ m⁻² s³, where the kilogram, metre and second are defined in terms of h, c and ΔνCs.

Defining Constant

Kcd = 683 lm W⁻¹ exactly at a frequency of 540 × 10¹² Hz.

Meaning

The definition establishes a precise relationship between radiant power and the corresponding photometric quantity for radiation at the specified frequency.

Visual Condition

The photometric definition is based on the standardized spectral luminous efficiency function for photopic, or daylight-adapted, human vision.

Physical Meaning

Luminous Intensity

Luminous intensity describes the luminous flux emitted per unit solid angle in a specified direction.

Photometry

Photometry measures optical radiation according to the standardized spectral sensitivity of human vision under specified viewing conditions.

Radiometry

Radiometry measures electromagnetic radiation in physical energy terms without weighting it according to human visual sensitivity.

Dimension

The candela is an SI base unit, but its dimensional representation in terms of the other base dimensions is commonly written as J, where J is the symbol for luminous intensity in dimensional analysis.

Photometric And Radiometric Quantities

Luminous Flux

Luminous flux is the rate of flow of visually weighted light and is measured in lumens (lm).

Luminous Intensity

Luminous intensity is luminous flux per unit solid angle and is measured in candelas (cd).

Illuminance

Illuminance is luminous flux incident per unit area and is measured in lux (lx), where 1 lx = 1 lm m⁻².

Luminance

Luminance describes luminous intensity per projected area in a specified direction and is measured in cd m⁻².

Radiant Flux

Radiant flux is optical or electromagnetic radiant power and is measured in watts (W).

Solid Angle

Solid angle is measured in steradians (sr). The steradian is a dimensionless derived SI unit with a special name.

Human Visual Response

Photopic Vision

Photopic vision refers to daylight-adapted vision, dominated by cone photoreceptors. The standardized photopic luminous efficiency function V(λ) describes the relative sensitivity of the average human observer under defined conditions.

Maximum Sensitivity

The photopic luminous efficiency function reaches its maximum at approximately 555 nm, corresponding to a frequency close to 540 × 10¹² Hz in vacuum.

Scotopic Vision

Scotopic vision refers to low-light vision dominated by rod photoreceptors. It has a different spectral sensitivity and is not the basis of the candela's defining frequency.

Mesopic Vision

Mesopic vision occurs between photopic and scotopic conditions and involves both rods and cones.

Important Clarification

The candela is a standardized photometric unit, not a direct measure of the total physical energy emitted by a light source.

Realization And Measurement

Radiometric Approach

A practical realization can use a calibrated radiometric source or detector and apply the standardized spectral luminous efficiency function to obtain photometric quantities.

Spectral Measurements

Spectroradiometers measure optical power as a function of wavelength. The measured spectrum can be weighted by V(λ) to determine photometric quantities.

Detector Based Methods

Photometric detectors are designed or corrected to approximate the standardized photopic response, and their calibration is traceable to radiometric standards.

Goniophotometry

A goniophotometer measures the angular distribution of luminous intensity from a source.

Environmental Factors

Stray light, detector spectral mismatch, temperature, source stability, alignment and measurement geometry can affect results.

Applications

  • Lighting design and architectural illumination.

  • Automotive headlights and signal lights.

  • Display and screen brightness measurement.

  • Street lighting and workplace illumination.

  • Photographic and cinematographic lighting.

  • Optical instrument calibration.

  • Vision research and lighting standards.

Limitations And Considerations

  • Luminous intensity is directional; a source may have different values in different directions.

  • Photometric values depend on the standardized human visual response, while radiometric values describe physical radiation.

  • The candela's definition is based on photopic vision and does not directly describe all low-light visual conditions.

  • A lamp's electrical power in watts is not the same as its luminous flux in lumens.

  • Measurement geometry and spectral distribution must be considered when comparing light sources.

Common Misconceptions

  • Candela is not a unit of total light output; lumen measures luminous flux.

  • Lux measures illuminance, not luminous intensity.

  • The watt measures radiant or electrical power, not perceived brightness.

  • The candela is not defined by a candle flame in the modern SI.

  • The specified 540 THz frequency is not the only frequency at which photometric quantities can be measured; it is the frequency used in the definition.

Variables

SymbolMeaningUnit

cd

Candela, SI base unit of luminous intensity

cd

Kcd

Maximum luminous efficacy of monochromatic radiation for the defined frequency

lm W⁻¹

Iv

Luminous intensity

cd

Φv

Luminous flux

lm

Ω

Solid angle

sr

Ev

Illuminance

lx

Lv

Luminance

cd m⁻²

V(λ)

Standard photopic spectral luminous efficiency function

Dimensionless

λ

Wavelength

m or nm

Example or application

A worked example has not yet been added.

Definition

The candela (cd) is the SI base unit of luminous intensity in a given direction, defined by fixing the luminous efficacy of monochromatic radiation at 540 × 10¹² Hz to exactly 683 lm W⁻¹.

Purpose

To provide an internationally standardized unit for measuring luminous intensity in a specified direction, taking account of the standardized sensitivity of human vision.

Importance

  • Supports standardized lighting design and evaluation.

  • Enables comparison of light sources based on visual effectiveness.

  • Provides a foundation for display, automotive and architectural photometry.

  • Connects radiometric measurements to human visual response.

  • Supports calibration of photometric instruments and lighting products.

Worked Example

ProblemSolutionAnswer

A source emits a luminous flux of 100 lm uniformly into a solid angle of 2 sr. Find its luminous intensity.

Iv = Φv/Ω = 100/2 = 50 cd.

50 cd

A luminous flux of 600 lm falls uniformly on an area of 3 m². Calculate the illuminance.

Ev = Φv/A = 600/3 = 200 lx.

200 lx

Reference

  • BIPM, The International System of Units (SI Brochure), 9th edition, section 2.3.7.

  • BIPM, SI Brochure, Appendix 2: Mise en pratique for the definition of the candela.

  • CIE, International Lighting Vocabulary.

  • NIST Special Publication 330, The International System of Units (SI).

Related Topic

  • SCI-REF-003-013

  • SCI-REF-003-014

  • SCI-REF-003-028

  • SCI-REF-003-029

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Units & Measurement