Derived Units in Optics, Photometry and Radiation

Optics, photometry and radiation science use specialized derived units to quantify light, electromagnetic radiation and its interaction with matter. Radiometry measures optical radiation in physical energy-based units, while photometry weights visible light according to the human visual response. Related quantities include radiant power, radiant energy, irradiance, radiance, luminous flux, luminous intensity, illuminance, luminance and radiation dose.

Radiometry

  • Radiant flux: Φₑ = dQₑ/dt; unit = W

  • Irradiance: Eₑ = dΦₑ/dA; unit = W·m⁻²

  • Radiant exitance: Mₑ = dΦₑ/dA; unit = W·m⁻²

  • Radiant intensity: Iₑ = dΦₑ/dΩ; unit = W·sr⁻¹

  • Radiance: Lₑ = d²Φₑ/(dA cos θ dΩ); unit = W·m⁻²·sr⁻¹

Photometry

  • Luminous flux: Φᵥ; unit = lm

  • Luminous intensity: Iᵥ = dΦᵥ/dΩ; unit = cd

  • Illuminance: Eᵥ = dΦᵥ/dA; unit = lx

  • Luminance: Lᵥ = d²Φᵥ/(dA cos θ dΩ); unit = cd·m⁻²

  • Luminous efficacy: ηᵥ = Φᵥ/P; unit = lm·W⁻¹

Radiation

  • Activity: A = −dN/dt; unit = Bq

  • Absorbed dose: D = dε/dm; unit = Gy = J·kg⁻¹

  • Equivalent dose: Hₜ = Σᵣ wᵣDₜᵣ; unit = Sv

  • Effective dose: E = Σₜ wₜHₜ; unit = Sv

  • Exposure: X = dQ/dm; unit = C·kg⁻¹

Wave Properties

  • Frequency: f = c/λ; unit = Hz

  • Wavenumber: ṽ = 1/λ; unit = m⁻¹ when λ is in metres

Explanation

HeadingContent

1. Scope of Optical and Radiation Measurement

Optics studies the behavior of light and electromagnetic radiation. Radiometry measures radiation in terms of physical energy, while photometry measures visible light according to a standardized human visual response. Radiation science also includes the measurement of ionizing radiation and its effects.

2. Radiometric and Photometric Quantities

Radiometric quantities are based on radiant energy and power. Photometric quantities are based on the visually weighted effect of visible radiation. Their units are related but not interchangeable. For example, radiant power is measured in watts, whereas luminous flux is measured in lumens.

3. Radiant Energy

Radiant energy is energy carried by electromagnetic radiation. Its SI unit is the joule (J). It may be measured over a specified wavelength range, frequency range, area or time interval.

4. Radiant Flux

Radiant flux is the rate of transfer of radiant energy. It is measured in watts (W), equivalent to joules per second. It describes the total radiant power emitted, transmitted or received.

5. Irradiance and Radiant Exitance

Irradiance is radiant power incident on a surface per unit area. Radiant exitance is radiant power leaving a surface per unit area. Both are measured in W/m², but they describe different directions of energy transfer.

6. Radiant Intensity and Radiance

Radiant intensity is radiant flux per unit solid angle and has unit W/sr. Radiance is radiant flux per unit projected area per unit solid angle and has unit W/(m²·sr). These quantities are important in imaging, optical systems and remote sensing.

7. Luminous Flux

Luminous flux measures the perceived rate of emission of visible light, weighted by the standardized photopic luminous efficiency function. Its SI unit is the lumen (lm), defined as cd·sr.

8. Luminous Intensity

Luminous intensity is luminous flux emitted per unit solid angle in a specified direction. Its SI unit is the candela (cd), one of the seven SI base units. It is a directional photometric quantity.

9. Illuminance

Illuminance measures luminous flux incident on a surface per unit area. Its SI unit is the lux (lx), equal to one lumen per square metre.

10. Luminance

Luminance describes the luminous intensity emitted or reflected from a surface in a specified direction per unit projected area. Its SI unit is candela per square metre (cd/m²). It is important in display technology, visual comfort and lighting design.

11. Luminous Efficacy

Luminous efficacy can refer to luminous flux per unit radiant power, measured in lm/W, or to luminous efficacy of a source based on electrical input power, also measured in lm/W. The denominator must be stated clearly because the two quantities are different.

12. Solid Angle

Solid angle measures the angular extent of a region in three-dimensional space. Its SI special unit is the steradian (sr), which is dimensionless. One steradian is the solid angle subtended at the center of a sphere by an area equal to the square of the sphere's radius.

13. Wavelength and Wavenumber

Wavelength is a length quantity measured in metres, often using prefixes such as nanometres. Wavenumber may mean reciprocal wavelength, with unit m⁻¹, or spectroscopic wavenumber, commonly expressed in reciprocal centimetres (cm⁻¹). The precise convention must be identified.

14. Optical Frequency

Optical frequency is the number of electromagnetic oscillations per second and is measured in hertz (Hz). It is related to wavelength in vacuum by f = c/λ.

15. Ionizing Radiation Activity

Radioactive activity is the rate of nuclear transformations and is measured in becquerels (Bq), where one becquerel equals one transformation per second. Activity describes the source, not the energy absorbed by a material.

16. Absorbed Dose

Absorbed dose is energy imparted by ionizing radiation per unit mass. Its SI unit is the gray (Gy), equal to one joule per kilogram.

17. Equivalent and Effective Dose

Equivalent dose accounts for the type of radiation through radiation weighting factors. Effective dose additionally accounts for the relative sensitivity of different tissues using tissue weighting factors. Both are measured in sieverts (Sv). They are radiation-protection quantities and are not interchangeable with absorbed dose.

18. Exposure in Air

Exposure is a radiological quantity describing the electric charge of ions of one sign produced in air by X-rays or gamma rays per unit mass of air. Its SI unit is coulomb per kilogram (C/kg). It is not the same as absorbed dose.

19. Spectral Quantities

Spectral radiometric quantities describe how radiation is distributed across wavelength or frequency. Their units include per metre, per nanometre or per hertz in the denominator, depending on the independent spectral variable. A spectral quantity must specify whether it is expressed per unit wavelength or per unit frequency.

20. Applications

These units are used in lighting design, photography, cameras, lasers, optical communication, astronomy, remote sensing, display engineering, medical imaging, radiation protection and nuclear science.

Variables

SymbolMeaningSi Unit

Qₑ

Radiant energy

J

Φₑ

Radiant flux

W

Eₑ

Irradiance

W·m⁻²

Iₑ

Radiant intensity

W·sr⁻¹

Lₑ

Radiance

W·m⁻²·sr⁻¹

Φᵥ

Luminous flux

lm

Iᵥ

Luminous intensity

cd

Eᵥ

Illuminance

lx

Lᵥ

Luminance

cd·m⁻²

A

Radioactive activity

Bq

D

Absorbed dose

Gy

Hₜ

Equivalent dose to tissue

Sv

E

Effective dose; context-dependent symbol

Sv

X

Radiation exposure in air

C·kg⁻¹

Example or application

A worked example has not yet been added.

Definition

Optical, photometric and radiation derived units are SI units used to quantify electromagnetic radiation, visible-light perception, optical power distribution and the physical and biological effects of ionizing radiation.

Purpose

To establish standardized measurement units for optical radiation, visible-light quantities and ionizing radiation quantities.

Importance

  • Supports accurate lighting design.

  • Enables comparison of optical sources and detectors.

  • Provides units for lasers and imaging systems.

  • Supports radiation protection and dosimetry.

  • Distinguishes physical radiation energy from visual response.

  • Enables consistent reporting in astronomy and remote sensing.

Worked Example

ProblemSolutionAnswer

A lamp produces a luminous flux of 1200 lm uniformly over a surface area of 4 m². Calculate the average illuminance, assuming all the flux reaches the surface.

  • Illuminance is Eᵥ = Φᵥ/A.

  • Eᵥ = 1200 lm/4 m².

  • Eᵥ = 300 lm/m².

300 lx.

A material of mass 2 kg absorbs 10 J of ionizing radiation energy. Calculate the absorbed dose.

  • Absorbed dose is D = energy/mass.

  • D = 10 J/2 kg.

  • D = 5 J/kg.

5 Gy.

Comparison

QuantityUnitMeaning

Radiant flux

W

Physical radiant power

Luminous flux

lm

Visible-light output weighted by standardized visual response

Irradiance

W/m²

Incident radiant power per unit area

Illuminance

lx

Incident luminous flux per unit area

Absorbed dose

Gy

Energy absorbed per unit mass

Equivalent dose

Sv

Radiation-weighted dose for protection purposes

Common Errors

  • Confusing lumens with watts.

  • Confusing illuminance with luminance.

  • Treating radiometry and photometry as identical.

  • Confusing radiant intensity with luminous intensity.

  • Treating becquerel as a unit of absorbed dose.

  • Treating gray and sievert as interchangeable.

  • Confusing exposure in C/kg with absorbed dose in Gy.

  • Reporting spectral quantities without specifying the spectral interval.

Learning Check

  • What is the difference between radiometry and photometry?

  • What does one lumen measure?

  • What is the SI unit of illuminance?

  • Distinguish radiant flux from luminous flux.

  • What is the difference between gray and sievert?

  • What does one becquerel represent?

  • Why must spectral quantities specify their wavelength or frequency interval?

Reference

TitleOrganizationUrl

The International System of Units (SI Brochure)

BIPM

https://www.bipm.org/en/publications/si-brochure

CIE International Lighting Vocabulary

International Commission on Illumination

https://cie.co.at/e-ilv

Radiological Protection and Safety of Radiation Sources: International Basic Safety Standards

International Atomic Energy Agency

https://www.iaea.org/publications/8930

Related Topic

  • SCI-REF-003-027

  • SCI-REF-003-032

  • SCI-REF-003-037

  • SCI-REF-003-039

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Units & Measurement