| Heading | Content |
|---|---|
1. Scope of Optical and Radiation Measurement | Optics studies the behavior of light and electromagnetic radiation. Radiometry measures radiation in terms of physical energy, while photometry measures visible light according to a standardized human visual response. Radiation science also includes the measurement of ionizing radiation and its effects. |
2. Radiometric and Photometric Quantities | Radiometric quantities are based on radiant energy and power. Photometric quantities are based on the visually weighted effect of visible radiation. Their units are related but not interchangeable. For example, radiant power is measured in watts, whereas luminous flux is measured in lumens. |
3. Radiant Energy | Radiant energy is energy carried by electromagnetic radiation. Its SI unit is the joule (J). It may be measured over a specified wavelength range, frequency range, area or time interval. |
4. Radiant Flux | Radiant flux is the rate of transfer of radiant energy. It is measured in watts (W), equivalent to joules per second. It describes the total radiant power emitted, transmitted or received. |
5. Irradiance and Radiant Exitance | Irradiance is radiant power incident on a surface per unit area. Radiant exitance is radiant power leaving a surface per unit area. Both are measured in W/m², but they describe different directions of energy transfer. |
6. Radiant Intensity and Radiance | Radiant intensity is radiant flux per unit solid angle and has unit W/sr. Radiance is radiant flux per unit projected area per unit solid angle and has unit W/(m²·sr). These quantities are important in imaging, optical systems and remote sensing. |
7. Luminous Flux | Luminous flux measures the perceived rate of emission of visible light, weighted by the standardized photopic luminous efficiency function. Its SI unit is the lumen (lm), defined as cd·sr. |
8. Luminous Intensity | Luminous intensity is luminous flux emitted per unit solid angle in a specified direction. Its SI unit is the candela (cd), one of the seven SI base units. It is a directional photometric quantity. |
9. Illuminance | Illuminance measures luminous flux incident on a surface per unit area. Its SI unit is the lux (lx), equal to one lumen per square metre. |
10. Luminance | Luminance describes the luminous intensity emitted or reflected from a surface in a specified direction per unit projected area. Its SI unit is candela per square metre (cd/m²). It is important in display technology, visual comfort and lighting design. |
11. Luminous Efficacy | Luminous efficacy can refer to luminous flux per unit radiant power, measured in lm/W, or to luminous efficacy of a source based on electrical input power, also measured in lm/W. The denominator must be stated clearly because the two quantities are different. |
12. Solid Angle | Solid angle measures the angular extent of a region in three-dimensional space. Its SI special unit is the steradian (sr), which is dimensionless. One steradian is the solid angle subtended at the center of a sphere by an area equal to the square of the sphere's radius. |
13. Wavelength and Wavenumber | Wavelength is a length quantity measured in metres, often using prefixes such as nanometres. Wavenumber may mean reciprocal wavelength, with unit m⁻¹, or spectroscopic wavenumber, commonly expressed in reciprocal centimetres (cm⁻¹). The precise convention must be identified. |
14. Optical Frequency | Optical frequency is the number of electromagnetic oscillations per second and is measured in hertz (Hz). It is related to wavelength in vacuum by f = c/λ. |
15. Ionizing Radiation Activity | Radioactive activity is the rate of nuclear transformations and is measured in becquerels (Bq), where one becquerel equals one transformation per second. Activity describes the source, not the energy absorbed by a material. |
16. Absorbed Dose | Absorbed dose is energy imparted by ionizing radiation per unit mass. Its SI unit is the gray (Gy), equal to one joule per kilogram. |
17. Equivalent and Effective Dose | Equivalent dose accounts for the type of radiation through radiation weighting factors. Effective dose additionally accounts for the relative sensitivity of different tissues using tissue weighting factors. Both are measured in sieverts (Sv). They are radiation-protection quantities and are not interchangeable with absorbed dose. |
18. Exposure in Air | Exposure is a radiological quantity describing the electric charge of ions of one sign produced in air by X-rays or gamma rays per unit mass of air. Its SI unit is coulomb per kilogram (C/kg). It is not the same as absorbed dose. |
19. Spectral Quantities | Spectral radiometric quantities describe how radiation is distributed across wavelength or frequency. Their units include per metre, per nanometre or per hertz in the denominator, depending on the independent spectral variable. A spectral quantity must specify whether it is expressed per unit wavelength or per unit frequency. |
20. Applications | These units are used in lighting design, photography, cameras, lasers, optical communication, astronomy, remote sensing, display engineering, medical imaging, radiation protection and nuclear science. |
Derived Units in Optics, Photometry and Radiation
Optics, photometry and radiation science use specialized derived units to quantify light, electromagnetic radiation and its interaction with matter. Radiometry measures optical radiation in physical energy-based units, while photometry weights visible light according to the human visual response. Related quantities include radiant power, radiant energy, irradiance, radiance, luminous flux, luminous intensity, illuminance, luminance and radiation dose.
Radiometry
Radiant flux: Φₑ = dQₑ/dt; unit = W
Irradiance: Eₑ = dΦₑ/dA; unit = W·m⁻²
Radiant exitance: Mₑ = dΦₑ/dA; unit = W·m⁻²
Radiant intensity: Iₑ = dΦₑ/dΩ; unit = W·sr⁻¹
Radiance: Lₑ = d²Φₑ/(dA cos θ dΩ); unit = W·m⁻²·sr⁻¹
Photometry
Luminous flux: Φᵥ; unit = lm
Luminous intensity: Iᵥ = dΦᵥ/dΩ; unit = cd
Illuminance: Eᵥ = dΦᵥ/dA; unit = lx
Luminance: Lᵥ = d²Φᵥ/(dA cos θ dΩ); unit = cd·m⁻²
Luminous efficacy: ηᵥ = Φᵥ/P; unit = lm·W⁻¹
Radiation
Activity: A = −dN/dt; unit = Bq
Absorbed dose: D = dε/dm; unit = Gy = J·kg⁻¹
Equivalent dose: Hₜ = Σᵣ wᵣDₜᵣ; unit = Sv
Effective dose: E = Σₜ wₜHₜ; unit = Sv
Exposure: X = dQ/dm; unit = C·kg⁻¹
Wave Properties
Frequency: f = c/λ; unit = Hz
Wavenumber: ṽ = 1/λ; unit = m⁻¹ when λ is in metres
Explanation
Variables
| Symbol | Meaning | Si Unit |
|---|---|---|
Qₑ | Radiant energy | J |
Φₑ | Radiant flux | W |
Eₑ | Irradiance | W·m⁻² |
Iₑ | Radiant intensity | W·sr⁻¹ |
Lₑ | Radiance | W·m⁻²·sr⁻¹ |
Φᵥ | Luminous flux | lm |
Iᵥ | Luminous intensity | cd |
Eᵥ | Illuminance | lx |
Lᵥ | Luminance | cd·m⁻² |
A | Radioactive activity | Bq |
D | Absorbed dose | Gy |
Hₜ | Equivalent dose to tissue | Sv |
E | Effective dose; context-dependent symbol | Sv |
X | Radiation exposure in air | C·kg⁻¹ |
Example or application
A worked example has not yet been added.
Definition
Optical, photometric and radiation derived units are SI units used to quantify electromagnetic radiation, visible-light perception, optical power distribution and the physical and biological effects of ionizing radiation.
Purpose
To establish standardized measurement units for optical radiation, visible-light quantities and ionizing radiation quantities.
Importance
Supports accurate lighting design.
Enables comparison of optical sources and detectors.
Provides units for lasers and imaging systems.
Supports radiation protection and dosimetry.
Distinguishes physical radiation energy from visual response.
Enables consistent reporting in astronomy and remote sensing.
Worked Example
| Problem | Solution | Answer |
|---|---|---|
A lamp produces a luminous flux of 1200 lm uniformly over a surface area of 4 m². Calculate the average illuminance, assuming all the flux reaches the surface. |
| 300 lx. |
A material of mass 2 kg absorbs 10 J of ionizing radiation energy. Calculate the absorbed dose. |
| 5 Gy. |
Comparison
| Quantity | Unit | Meaning |
|---|---|---|
Radiant flux | W | Physical radiant power |
Luminous flux | lm | Visible-light output weighted by standardized visual response |
Irradiance | W/m² | Incident radiant power per unit area |
Illuminance | lx | Incident luminous flux per unit area |
Absorbed dose | Gy | Energy absorbed per unit mass |
Equivalent dose | Sv | Radiation-weighted dose for protection purposes |
Common Errors
Confusing lumens with watts.
Confusing illuminance with luminance.
Treating radiometry and photometry as identical.
Confusing radiant intensity with luminous intensity.
Treating becquerel as a unit of absorbed dose.
Treating gray and sievert as interchangeable.
Confusing exposure in C/kg with absorbed dose in Gy.
Reporting spectral quantities without specifying the spectral interval.
Learning Check
What is the difference between radiometry and photometry?
What does one lumen measure?
What is the SI unit of illuminance?
Distinguish radiant flux from luminous flux.
What is the difference between gray and sievert?
What does one becquerel represent?
Why must spectral quantities specify their wavelength or frequency interval?
Reference
| Title | Organization | Url |
|---|---|---|
The International System of Units (SI Brochure) | BIPM | https://www.bipm.org/en/publications/si-brochure |
CIE International Lighting Vocabulary | International Commission on Illumination | https://cie.co.at/e-ilv |
Radiological Protection and Safety of Radiation Sources: International Basic Safety Standards | International Atomic Energy Agency | https://www.iaea.org/publications/8930 |
Related Topic
SCI-REF-003-027
SCI-REF-003-032
SCI-REF-003-037
SCI-REF-003-039
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement