The measurement range specifies the interval over which an instrument is intended to operate under stated conditions. The span is the numerical difference between the upper and lower range limits. Resolution describes the smallest input change that produces a detectable change in indication. Sensitivity describes the ratio between output change and input change. Threshold describes the minimum input level or change required to produce a detectable response, depending on the instrument and specification.
For an analogue scale, resolution may be limited by the smallest readable scale division and the observer's ability to interpolate. For a digital instrument, it may be related to the least significant digit, display count or analogue-to-digital converter step. However, display resolution is not necessarily the same as effective measurement resolution because noise, drift and calibration uncertainty may be larger than one display count.
Sensitivity depends on the instrument's transfer function. A sensor may have constant sensitivity over its range, or sensitivity may vary with input. In a nonlinear instrument, local sensitivity is represented by the derivative of output with respect to input. Threshold and resolution may also depend on noise level, filtering, sampling rate and detection criteria.
Resolution, Sensitivity, Range and Threshold of Instruments
Resolution, sensitivity, range and threshold are fundamental instrument specifications that determine what an instrument can measure, how small a change it can distinguish and how strongly its output responds to changes in the measurand. They are related but represent different properties and must be evaluated separately.
Span
Span = Upper range limit − Lower range limit
Average Sensitivity
S_avg = Δy / Δx
Local Sensitivity
S(x) = dy/dx
Digital Step
q = (Upper limit − Lower limit) / Number of intervals
Relative Resolution
r = q / x_range × 100%
Note
The digital-step expression is an idealized model. Actual converter resolution, display counts, coding, noise and measurement range must be considered when evaluating a real instrument.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
S | Instrument sensitivity | Output unit per input unit |
Δy | Change in instrument output | Output unit |
Δx | Change in measurand | Input unit |
q | Smallest nominal digital step | Input unit |
x_range | Specified measurement span | Input unit |
Example or application
A worked example has not yet been added.
Definition
Range
The set of values of a quantity that an instrument is designed to measure under specified conditions.
Span
The difference between the upper and lower limits of the specified measurement range.
Resolution
The smallest change in the quantity being measured that causes a perceptible change in the corresponding indication.
Sensitivity
The change in instrument output divided by the corresponding change in input.
Threshold
The minimum input level or input change that produces a detectable response under specified conditions.
Least Significant Digit
The digit position representing the smallest displayed increment in a digital indication.
Purpose
To determine whether an instrument can cover the expected values, distinguish the required changes and provide an output sufficiently responsive for the measurement task.
Importance
Incorrect interpretation of these parameters can lead to selecting an instrument that saturates, misses small changes or displays more digits than its measurement performance justifies.
Range And Span
Lower Range Limit
The lowest specified value that the instrument can measure.
Upper Range Limit
The highest specified value that the instrument can measure.
Unidirectional Range
A range that extends in one direction from a reference, commonly zero.
Bidirectional Range
A range that includes positive and negative values around a reference.
Overrange
An input exceeding the specified measurement range. The instrument may give an invalid indication or suffer damage unless protected.
Selection Rule
Choose a range that covers all expected values while providing suitable resolution and uncertainty. Avoid unnecessary over-ranging when it reduces usable resolution.
Resolution Types
Analogue Resolution
Often related to the smallest scale division, pointer width, viewing conditions and interpolation capability.
Digital Display Resolution
The smallest change in input represented by a change in the displayed digit or count.
Adc Resolution
For an ideal n-bit analogue-to-digital converter, there are 2ⁿ possible output codes. The nominal step size depends on the converter's defined input range and coding convention.
Effective Resolution
The useful distinguishable input change after accounting for noise, nonlinearity, drift and other practical effects.
Sensitivity Behavior
Constant Sensitivity
The output changes proportionally with the input over a specified range.
Variable Sensitivity
The input-output slope changes with operating point.
High Sensitivity
A small input change produces a relatively large output change, which may improve detectability but can also amplify noise or make the system more susceptible to disturbances.
Low Sensitivity
A larger input change is needed to produce the same output change.
Threshold And Detection
Threshold Of Measurement
The lowest input that can be reliably detected according to a stated procedure.
Noise Influence
Random noise can hide small signals and make the effective threshold higher.
Filtering Influence
Filtering may improve detectability of slow signals but can reduce response speed or suppress rapid changes.
Zero Threshold
Some instruments are designed to respond close to zero input, but practical noise and offset prevent perfect detection of arbitrarily small quantities.
Worked Examples
| Problem | Solution |
|---|---|
An instrument has a range of 0 to 250 °C. Find its span. | Span = 250 °C − 0 °C = 250 °C. |
An instrument output changes from 1.0 V to 5.0 V when the input changes from 10 units to 30 units. Find average sensitivity. | S = (5.0 − 1.0) V/(30 − 10) units = 4.0/20 = 0.20 V per input unit. |
A digital instrument displays values in steps of 0.01 mm. What is its display resolution? | The smallest displayed increment is 0.01 mm. This is the display resolution; it does not establish that the instrument's accuracy or uncertainty is also 0.01 mm. |
An ideal 12-bit converter covers an input span of 10 V. Estimate the nominal step using 2¹² intervals. | Number of codes = 4096. Nominal step = 10 V/4096 ≈ 0.00244 V = 2.44 mV. Actual endpoint and code-width conventions depend on the converter design. |
Selection Guidelines
Confirm the minimum and maximum expected measurand values.
Choose a range that safely covers the expected values.
Determine the smallest change that must be detected.
Compare required resolution with the instrument's effective resolution.
Check sensitivity over the actual operating range.
Evaluate threshold, noise and environmental influences.
Check accuracy and uncertainty independently of display resolution.
Consider response time and sampling frequency for changing quantities.
Common Mistakes
Confusing range with span.
Assuming a high-resolution display guarantees high accuracy.
Assuming sensitivity and resolution mean the same thing.
Ignoring instrument saturation beyond the upper range limit.
Treating the smallest displayed digit as the smallest reliably measurable change.
Comparing resolution values without considering different measurement ranges.
Applications
Selecting digital multimeters and oscilloscopes
Choosing temperature and pressure sensors
Precision dimensional measurement
Data acquisition and automation
Scientific experiments requiring detection of small changes
Reference
JCGM 200, International Vocabulary of Metrology (VIM).
NIST, Special Publication 811, Guide for the Use of the International System of Units (SI).
IEC 61010 series, Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use.
Related Topic
Measuring Instrument Characteristics and Performance Parameters
Introduction to Measuring Instruments and Instrument Classification
Measurement Uncertainty
Digital Measurement Systems
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement