Mass is an intrinsic property of an object in classical mechanics and does not change merely because the object is moved to a different gravitational field. Weight is the gravitational force acting on the object and depends on local gravitational acceleration. Near Earth's surface, the magnitude of weight is approximately the product of mass and local gravitational acceleration.
A beam balance compares an unknown mass with known reference masses. Under ideal conditions, equal gravitational acceleration acts on both sides, allowing a mass comparison. An electronic balance commonly uses an electromagnetic force-compensation mechanism or a load cell to measure the force required to support the object and converts the signal into a mass indication through calibration.
A spring balance measures force through elastic deformation of a spring. When calibrated as a weight-measuring device, its reading depends on the local gravitational field unless corrected. A load cell converts applied force into an electrical signal, often through strain gauges, piezoelectric elements or other sensing technologies.
Mass measurements require attention to air buoyancy, balance sensitivity, calibration, vibration, temperature, static electricity, magnetic effects and the placement of the object. High-precision mass metrology may require corrections for air buoyancy and comparison with traceable mass standards.
Mass and Weight Measurement Instruments
Mass and weight are different physical quantities and require different measurement concepts. Mass is a measure of inertia and is expressed in kilograms, while weight is a gravitational force and is expressed in newtons. Balances commonly determine mass by comparison or force compensation, whereas force-measuring devices can determine weight directly.
Weight
W = mg
Mass From Weight
m = W/g
Spring Extension Idealization
F = kx
Relative Difference
δ = (m_indicated − m_reference) / m_reference
Buoyancy Force
F_b = ρ_air V g
Note
The spring equation is an ideal linear model. Actual spring balances may require calibration and corrections for nonlinearity, hysteresis and temperature.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
m | Mass | kg |
W | Weight force | N |
g | Local gravitational acceleration | m·s⁻² |
k | Spring stiffness | N·m⁻¹ |
x | Spring extension | m |
ρ_air | Air density | kg·m⁻³ |
V | Volume of displaced air | m³ |
Example or application
A worked example has not yet been added.
Definition
Mass
A physical quantity associated with inertia and the amount of matter in a body; its SI unit is the kilogram (kg).
Weight
The gravitational force acting on a body; its SI unit is the newton (N).
Balance
An instrument used to determine mass, commonly by comparing or compensating for the gravitational force on an object.
Load Cell
A force transducer that converts applied load into an electrical output.
Calibration Mass
A mass standard with an assigned value and associated uncertainty used to calibrate or verify a weighing instrument.
Purpose
To determine the mass of objects or the force associated with their weight for laboratory experiments, commercial transactions, industrial processes and engineering measurements.
Importance
Reliable mass and force measurement are essential for material formulation, trade, chemical preparation, manufacturing, structural testing, logistics and scientific research.
Mass Versus Weight
Mass
Measured in kilograms; scalar in classical mechanics; measures inertia; does not depend on local gravitational acceleration.
Weight
Measured in newtons; a force; depends on the gravitational field; may vary with location or altitude.
Example
An object of mass 2 kg has a weight of approximately 19.6 N where g ≈ 9.81 m·s⁻². Its mass remains 2 kg when moved to a different location, although its weight may change.
Instrument Types
Beam Balance
Compares an unknown mass with reference masses through mechanical equilibrium.
Analytical Balance
A high-resolution laboratory balance designed for precise mass measurements, commonly with a draft shield.
Precision Balance
A laboratory balance designed for general accurate weighing with a broader capacity than many analytical balances.
Top Loading Balance
A balance with a platform or pan on which objects are placed from above.
Spring Balance
Measures force through spring deformation and may be graduated to indicate weight under specified gravitational conditions.
Electronic Load Cell Scale
Uses a force transducer and electronic processing to produce a mass or force indication.
Mass Comparator
Compares mass standards with high precision, often using substitution or electronic force compensation.
Measurement Principles
Comparison
An unknown mass is compared with known standards. A balance may reach equilibrium when the gravitational moments or forces are appropriately balanced.
Force Compensation
A controlled electromagnetic or other force balances the load, and the compensating signal is related to the applied force.
Strain Gauge
Applied force deforms an elastic element and changes the resistance of bonded or integrated strain gauges.
Spring Deflection
Applied force produces elastic displacement related to spring stiffness within the elastic operating region.
Measurement Procedure
Place the balance on a stable, level surface.
Check that the instrument is within its operating environment and calibration status.
Allow the instrument to warm up or stabilize if required.
Ensure the weighing pan is clean and the display is stable.
Tare the balance with the empty container when appropriate.
Place the object centrally and avoid touching it unnecessarily.
Allow the indication to stabilize before recording.
Apply relevant corrections when high-accuracy mass measurement requires them.
Record the value, unit, instrument identification and relevant conditions.
Remove the object and verify that the instrument returns to the expected zero condition.
Worked Examples
| Problem | Solution |
|---|---|
Find the approximate weight of a 5.0 kg object where g = 9.81 m·s⁻². | W = mg = 5.0 × 9.81 = 49.05 N. |
A force instrument indicates a weight of 98.1 N where local gravitational acceleration is 9.81 m·s⁻². Estimate the mass. | m = W/g = 98.1/9.81 = 10.0 kg. |
A spring with stiffness 200 N·m⁻¹ extends by 0.015 m. Estimate the force under the ideal linear model. | F = kx = 200 × 0.015 = 3.0 N. |
Important Corrections
Air Buoyancy
Air exerts an upward buoyant force on objects and calibration masses. This can influence high-precision mass comparisons.
Local Gravity
A force-based weighing system calibrated at one gravitational acceleration may require adjustment or compensation when used elsewhere.
Temperature
Temperature can affect balance mechanisms, load cells, reference masses and air density.
Vibration
Mechanical vibration can destabilize the indication.
Static Electricity
Electrostatic forces can disturb measurements of small masses.
Magnetic Effects
Magnetic materials or fields can influence sensitive weighing systems.
Common Mistakes
Using kilograms as the unit of weight instead of newtons.
Assuming a spring balance measures mass directly.
Ignoring local gravity when interpreting force-based weight measurements.
Failing to tare a container when required.
Placing objects off-centre or weighing in an unstable environment.
Assuming every electronic balance has the same resolution and uncertainty.
Applications
Chemical and pharmaceutical laboratories
Commercial and industrial weighing
Material testing and manufacturing
Agriculture and food processing
Logistics and shipping
Mechanical force experiments
Mass-standard calibration laboratories
Reference
BIPM, The International System of Units (SI Brochure), 9th edition.
JCGM 200, International Vocabulary of Metrology (VIM).
OIML R 76, Non-automatic Weighing Instruments.
Related Topic
Introduction to Measuring Instruments and Instrument Classification
Measurement of Length, Distance, Area and Volume
Pressure, Force and Torque Measurement Instruments
Measurement Uncertainty
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement