Temperature is a thermodynamic quantity whose SI base unit is the kelvin (K). A thermometer does not measure temperature by observing an abstract quantity directly; it detects a physical property that changes in a known relationship with temperature. The instrument is calibrated so that its output can be interpreted as a temperature value.
Liquid-in-glass thermometers use thermal expansion of a liquid. Bimetallic thermometers use the different thermal expansion coefficients of bonded metals. Resistance temperature detectors (RTDs) use the temperature dependence of electrical resistance, commonly in platinum elements. Thermistors use a strong resistance-temperature relationship in semiconductor materials. Thermocouples generate a thermoelectric voltage related to the temperature difference between two junctions. Infrared thermometers estimate surface temperature from detected thermal radiation and require appropriate emissivity and environmental assumptions.
Temperature sensors differ in range, sensitivity, accuracy, response time, stability, contact requirements and suitability for different environments. Contact sensors may disturb small or low-thermal-mass objects, while infrared sensors can be affected by emissivity, reflected radiation, viewing geometry and atmospheric absorption.
A reliable temperature measurement requires suitable sensor placement, thermal contact or optical alignment, sufficient stabilization time, correct calibration and consideration of heat transfer between the sensor and its surroundings.
Temperature Measurement Instruments and Sensors
Temperature measurement instruments determine the thermal state of a body, substance or environment. They operate through temperature-dependent physical properties such as thermal expansion, electrical resistance, thermoelectric voltage, semiconductor behavior and emitted infrared radiation.
Resistance Approximation
R(T) ≈ R₀[1 + α(T − T₀)]
Thermocouple Output
E ≈ S(T_hot − T_ref)
Temperature Conversion
T/K = t/°C + 273.15
Thermal Radiation
P = εσAT⁴
Note
The resistance and thermocouple equations are simplified approximations. Real sensor calibration uses appropriate reference functions, calibration curves or standardized tables. The radiation equation describes idealized total emitted power for a surface under stated assumptions.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
T | Thermodynamic temperature | K |
R(T) | Sensor resistance at temperature T | Ω |
R₀ | Reference resistance at temperature T₀ | Ω |
α | Temperature coefficient of resistance in the approximation | K⁻¹ |
E | Thermoelectric voltage | V |
S | Approximate thermoelectric sensitivity | V·K⁻¹ |
ε | Surface emissivity | Dimensionless |
σ | Stefan–Boltzmann constant | W·m⁻²·K⁻⁴ |
A | Radiating surface area | m² |
Example or application
A worked example has not yet been added.
Definition
Temperature
A thermodynamic quantity that characterizes thermal state and determines the direction of spontaneous heat transfer between systems in thermal contact.
Thermometer
An instrument that indicates temperature using a calibrated temperature-dependent property.
Temperature Sensor
A sensing element that responds to temperature and produces a measurable output.
Thermocouple
A temperature sensor formed by two dissimilar conductors joined to produce a thermoelectric voltage related to the temperature difference between junctions.
Emissivity
The ratio of radiation emitted by a real surface to that emitted by an ideal blackbody at the same temperature and under the same specified conditions.
Purpose
To determine and monitor temperature in experiments, manufacturing, environmental observation, healthcare, energy systems and industrial process control.
Importance
Temperature affects chemical reaction rates, material properties, biological processes, electrical resistance, phase changes and energy transfer. Reliable temperature measurement is therefore essential across nearly every scientific and engineering discipline.
Instrument Types
Liquid In Glass Thermometer
Uses expansion of a liquid in a calibrated capillary. It is simple but may be fragile and relatively slow.
Bimetallic Thermometer
Uses differential thermal expansion of two bonded metals to produce mechanical movement.
RTD
Uses the resistance-temperature relationship of a metal sensing element, commonly platinum, and offers good stability.
Thermistor
Uses a semiconductor element with a strong resistance change as temperature changes. Common types have negative or positive temperature coefficients.
Thermocouple
Uses the Seebeck effect to produce a voltage related to the temperature difference between measuring and reference junctions.
Semiconductor Temperature Sensor
Uses temperature-dependent semiconductor junction or integrated-circuit behavior to provide an electrical output.
Infrared Thermometer
Estimates surface temperature from infrared radiation without direct contact.
Thermal Camera
Produces a spatial map of apparent surface temperature from infrared measurements.
Measurement Principles
Thermal Expansion
A material changes dimensions or volume with temperature.
Resistance Change
Electrical resistance varies with temperature.
Thermoelectric Effect
A temperature difference between dissimilar conductors produces an electromotive force.
Semiconductor Response
Electrical properties of semiconductor junctions and devices vary with temperature.
Infrared Radiation
Thermal radiation emitted by a surface carries information about its temperature and emissivity.
Sensor Selection
Required temperature range
Required accuracy and uncertainty
Response time and thermal mass
Contact or non-contact measurement
Chemical compatibility and environmental resistance
Stability, calibration interval and long-term drift
Sensor interchangeability and signal-conditioning needs
Electrical noise and lead-wire effects
Surface emissivity and optical conditions for infrared instruments
Measurement Procedure
Define whether the required quantity is surface, internal, ambient or fluid temperature.
Choose a sensor with a suitable range and calibration specification.
Check sensor condition, calibration and electrical connections.
Place the sensor at a representative measurement location.
Ensure suitable thermal contact for contact sensors.
Avoid excessive heat conduction through sensor leads where it can bias the result.
Allow sufficient time for thermal equilibrium or a defined response criterion.
For infrared measurement, set or determine emissivity and appropriate viewing geometry.
Record the measured value, unit, sensor type, location and relevant conditions.
Apply calibration corrections and evaluate uncertainty where required.
Worked Examples
| Problem | Solution |
|---|---|
A platinum resistance sensor has R₀ = 100 Ω at T₀ and an approximate temperature coefficient α = 0.00385 K⁻¹. Estimate its resistance increase for a 10 K rise using the linear model. | ΔR ≈ R₀αΔT = 100 × 0.00385 × 10 = 3.85 Ω. The estimated resistance is 103.85 Ω. |
Convert 25 °C to kelvin. | T = 25 + 273.15 = 298.15 K. |
A thermocouple has an approximate sensitivity of 40 μV/K and a temperature difference of 100 K. Estimate its output using the linear approximation. | E ≈ 40 μV/K × 100 K = 4000 μV = 4.0 mV. |
Measurement Errors And Limitations
Thermal Lag
The sensor may take time to reach the temperature of the measured object.
Stem Conduction
Heat may flow along the sensor stem or leads, causing the sensing element to differ from the local measurand temperature.
Self Heating
Electrical current through a resistance sensor can heat the sensing element.
Emissivity Error
Infrared temperature estimates can be inaccurate if surface emissivity is incorrectly set.
Reference Junction Error
Thermocouple measurements require appropriate reference-junction compensation.
Calibration Drift
Sensor characteristics can change with age, thermal cycling or harsh operating conditions.
Common Mistakes
Confusing Celsius temperature values with kelvin values without applying the offset.
Assuming all temperature sensors measure the same physical property.
Ignoring response time and sensor placement.
Using an infrared thermometer without considering emissivity.
Ignoring thermocouple reference-junction compensation.
Assuming a linear sensor equation is valid across the entire temperature range.
Applications
Industrial furnaces and process control
Laboratory experiments
Weather and environmental monitoring
Food storage and processing
Medical and biomedical equipment
Automotive engines and battery systems
Building energy management
Thermal imaging and equipment inspection
Reference
BIPM, The International System of Units (SI Brochure), 9th edition.
NIST, Thermocouple Reference Tables and Temperature Measurement publications.
IEC 60751, Industrial platinum resistance thermometers and platinum temperature sensors.
Related Topic
Kelvin (K): Unit of Thermodynamic Temperature
Temperature Scales and Temperature Conversion
Derived Units in Thermodynamics and Heat Transfer
Advanced Electronic, Digital and Automated Measurement Systems
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement