Optical measurement is based on interactions between electromagnetic radiation and matter, including reflection, refraction, absorption, transmission, scattering, diffraction and interference. Instruments may use lenses, mirrors, filters, gratings, detectors, lasers and image sensors to obtain measurement information.
Radiometry quantifies optical radiation in terms of radiant energy or power, independent of human visual response. Photometry weights visible radiation according to the standardized spectral luminous efficiency function for human vision. Consequently, radiant power and luminous flux are not interchangeable. A radiometer measures radiant quantities, while a photometer measures photometric quantities such as illuminance or luminous intensity.
Common instruments include photometers, lux meters, spectrometers, spectrophotometers, optical power meters, refractometers, interferometers, microscopes, telescopes, laser displacement sensors and imaging systems. Their performance depends on spectral response, wavelength calibration, detector linearity, optical alignment, stray light, aperture, spatial resolution and environmental conditions.
A measurement must identify the relevant optical quantity and geometry. For example, illuminance is luminous flux incident per unit area, while luminance describes luminous intensity per projected area in a specified direction. A lux meter cannot directly replace a radiometer when the required quantity is radiant power.
Optical and Photometric Measurement Instruments
Optical measurement instruments use light to determine physical quantities such as wavelength, intensity, reflectance, transmittance, refractive index, surface characteristics and dimensions. Photometric instruments measure light according to the spectral sensitivity of human vision, while radiometric instruments measure optical radiation in physical energy terms.
Illuminance
E_v = Φ_v/A
Luminous Intensity
I_v = dΦ_v/dΩ
Radiant Irradiance
E_e = dΦ_e/dA
Transmittance
T = P_transmitted/P_incident
Absorbance
A = −log₁₀(T)
Snell Law
n₁ sin θ₁ = n₂ sin θ₂
Diffraction Grating
d sin θ = mλ
Note
The photometric expressions depend on the specified geometry and photometric conventions. The diffraction-grating relation applies to the usual plane-grating geometry under the corresponding sign and order conventions.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
Φ_v | Luminous flux | lm |
E_v | Illuminance | lx |
I_v | Luminous intensity | cd |
Ω | Solid angle | sr |
Φ_e | Radiant flux | W |
E_e | Radiant irradiance | W·m⁻² |
T | Transmittance | Dimensionless |
n | Refractive index | Dimensionless |
λ | Wavelength | m |
θ | Angle | rad |
Example or application
A worked example has not yet been added.
Definition
Optical Measurement
Measurement using the properties or interactions of light and other optical radiation.
Radiometry
The science of measuring electromagnetic radiation in terms of radiant energy and power.
Photometry
The measurement of light according to the standardized spectral response of human vision.
Spectrometer
An instrument that separates radiation according to wavelength, frequency or another spectral variable.
Spectrophotometer
An instrument that measures spectral transmittance, absorbance or reflectance under specified conditions.
Illuminance
Luminous flux incident on a surface per unit area.
Luminance
Photometric quantity describing luminous intensity per projected area in a specified direction.
Purpose
To measure optical radiation, characterize light sources and materials, inspect surfaces, determine spectral properties and quantify illumination in scientific, industrial and environmental settings.
Importance
Optical and photometric measurements support lighting design, optical communications, astronomy, spectroscopy, medical imaging, semiconductor manufacturing, materials science and quality control.
Instrument Types
Photometer
Measures photometric quantities such as illuminance or luminous intensity according to its design.
Lux Meter
Measures illuminance in lux at a specified location and orientation.
Spectrometer
Measures the distribution of radiation over wavelength or frequency.
Spectrophotometer
Measures spectral transmittance, absorbance or reflectance.
Radiometer
Measures radiant power or related radiometric quantities.
Optical Power Meter
Measures optical power, commonly in optical-fibre systems.
Refractometer
Determines refractive index using refraction or related optical effects.
Interferometer
Uses interference to measure optical path differences, displacement or surface properties.
Microscope
Uses optical imaging to magnify and examine small structures.
Telescope
Collects and forms images of distant objects using optical systems.
Laser Displacement Sensor
Uses reflected or interferometric laser light to determine distance or displacement.
Photometric And Radiometric Distinction
Radiant Flux
Total radiant power emitted, transmitted or received; SI unit watt (W).
Luminous Flux
Radiant power weighted by the standardized human visual response; SI unit lumen (lm).
Radiant Intensity
Radiant power per unit solid angle; SI unit W·sr⁻¹.
Luminous Intensity
Luminous flux per unit solid angle; SI unit candela (cd).
Irradiance
Incident radiant power per unit area; SI unit W·m⁻².
Illuminance
Incident luminous flux per unit area; SI unit lux (lx).
Radiance
Radiant intensity per projected area; SI unit W·m⁻²·sr⁻¹.
Luminance
Photometric counterpart of radiance; SI unit cd·m⁻².
Measurement Principles
Photoelectric Detection
A detector converts incident light into an electrical signal.
Spectral Dispersion
A prism, grating or interferometric arrangement separates radiation by wavelength or frequency.
Interference
Superposition of coherent waves produces patterns related to optical path difference.
Refraction
Changes in propagation direction at an interface provide information about refractive index.
Absorption
Reduction in transmitted intensity provides information about absorbing materials.
Imaging
Optical systems form images that can be analyzed for dimensions, shape and surface features.
Measurement Procedure
Define the required optical or photometric quantity.
Select an instrument with a suitable wavelength range, spectral response and measurement range.
Check calibration, detector condition and optical cleanliness.
Set the measurement geometry, aperture, distance and orientation.
Control ambient light and stray radiation where required.
Allow the detector and electronics to stabilize.
Take background or dark measurements if the method requires them.
Measure the sample and reference under comparable conditions.
Apply appropriate calibration and correction factors.
Record the result, units, wavelength range, geometry and uncertainty information.
Worked Examples
| Problem | Solution |
|---|---|
A surface receives a luminous flux of 600 lm uniformly over an area of 3.0 m². Find the average illuminance. | E_v = Φ_v/A = 600/3.0 = 200 lx. |
A material transmits 25% of incident optical power. Find its absorbance using the ideal transmittance expression. | T = 0.25. A = −log₁₀(0.25) ≈ 0.602. |
A diffraction grating has spacing d = 1.0 μm. For first order, the diffraction angle is 30°. Estimate the wavelength. | d sin θ = mλ. λ = (1.0 × 10⁻⁶ × sin 30°)/1 = 5.0 × 10⁻⁷ m = 500 nm. |
Measurement Limitations
Spectral Mismatch
A detector whose spectral response differs from the intended standard may produce biased photometric results.
Stray Light
Unwanted light can affect low-level and spectral measurements.
Alignment
Optical measurements can be sensitive to angular and positional alignment.
Surface Properties
Reflectance and emissivity may depend on wavelength, surface finish and viewing geometry.
Detector Linearity
Detector response may deviate from proportionality at very low or high signal levels.
Environment
Temperature, vibration, ambient light and contamination can affect results.
Common Mistakes
Confusing lux with watts per square metre.
Treating lumen and candela as interchangeable.
Ignoring wavelength dependence in optical measurements.
Using a lux meter to determine radiant power without an appropriate conversion model.
Ignoring the orientation and position of a photometric sensor.
Failing to account for background light and stray radiation.
Applications
Lighting design and workplace illumination
Spectroscopy and chemical analysis
Optical-fibre communications
Astronomy and remote sensing
Microscopy and biomedical imaging
Semiconductor and surface inspection
Laser measurement and optical metrology
Reference
BIPM, The International System of Units (SI Brochure), 9th edition.
CIE, International Lighting Vocabulary and relevant photometry standards.
NIST, Optical Radiation Measurements publications.
Related Topic
Derived Units in Optics, Photometry and Radiation
Candela (cd): Unit of Luminous Intensity
Measurement of Length, Distance, Area and Volume
Advanced Electronic, Digital and Automated Measurement Systems
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement