✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-003-073

Introduction to Measurement Errors

Measurement error is the difference between a measured value and an appropriate reference value of the quantity being measured. It is an unavoidable consideration in experimental science, engineering, manufacturing, healthcare, environmental monitoring and other fields that depend on quantitative observations. Understanding measurement errors is essential for evaluating the reliability of results, interpreting experimental data, comparing measurements and making scientifically justified conclusions.

Signed measurement error: e = xₘ − xᵣ
Absolute error magnitude: |e| = |xₘ − xᵣ|
Relative error: eᵣ = |xₘ − xᵣ| / |xᵣ|, for xᵣ ≠ 0
Percentage error: eₚ = (|xₘ − xᵣ| / |xᵣ|) × 100%
Measurement result: y = ŷ ± U, when U is a stated uncertainty with a defined interpretation.

Explanation

Measurement is the process of experimentally obtaining one or more quantity values that can reasonably be attributed to a physical quantity. No measurement should automatically be regarded as perfectly exact. Every measurement has limitations arising from the measuring instrument, measurement procedure, environment, observer, reference standards and the physical nature of the quantity.

A measurement result is generally represented by a numerical value together with its unit and, where appropriate, an associated measurement uncertainty. For example, reporting a length as 12.46 cm communicates a measured value, but does not by itself explain how reliable that value is. A more informative result may be written as (12.46 ± 0.02) cm, provided that the meaning and coverage of the stated uncertainty are specified.

Measurement error and measurement uncertainty are related but different concepts. Measurement error is the difference between a measured quantity value and a reference quantity value. Measurement uncertainty is a non-negative parameter characterizing the dispersion of quantity values attributed to a measurand, based on the information used. Error is generally unknown exactly because the true value or reference value may not be known with sufficient certainty. Uncertainty expresses the doubt associated with a measurement result; it is not simply the actual error.

A reference value may be obtained from a calibrated reference standard, a certified reference material, a higher-accuracy measurement procedure or an accepted conventional value. In practical experiments, the reference value itself may also have uncertainty. Consequently, comparisons must consider the quality and uncertainty of both the measurement and the reference.

Measurement errors can arise at different stages. During instrument preparation, an incorrect zero setting may introduce an offset. During measurement, friction, parallax, environmental temperature, electrical interference or changing experimental conditions may affect the result. During data processing, incorrect unit conversion, inappropriate rounding, transcription mistakes or an unsuitable mathematical model may produce additional errors.

Errors are commonly studied through their patterns and causes. Systematic effects tend to produce a consistent bias or predictable change, while random effects produce variation among repeated observations. Gross mistakes, such as reading the wrong scale or recording an incorrect digit, can produce unusually large deviations. These categories are useful for investigation, although real measurement systems may contain several effects simultaneously.

Repeated measurements help reveal variation and identify unusual observations. However, repeating a measurement does not automatically eliminate a systematic bias. A measuring instrument that consistently reads 0.5 mm too high may produce highly repeatable results while remaining inaccurate relative to the reference.

A complete measurement process therefore includes defining the measurand, selecting an appropriate method and instrument, calibrating or verifying the instrument, controlling relevant conditions, collecting observations, evaluating uncertainty, checking for errors and reporting the result with suitable units and precision.

Variables

SymbolMeaningUnit

xₘ

Measured value of the quantity

Same unit as the measured quantity

xᵣ

Reference value used for comparison

Same unit as the measured quantity

e

Signed measurement error

Same unit as the measured quantity

|e|

Magnitude of the measurement error

Same unit as the measured quantity

eᵣ

Relative error magnitude

Dimensionless

eₚ

Percentage error

%

ŷ

Reported estimate of the measurand

Unit of the measurand

U

Expanded uncertainty when the reporting convention uses this symbol

Unit of the measurand

Example or application

A worked example has not yet been added.

Definition

Measurement error is the difference between a measured quantity value and a reference quantity value. For a measured value xₘ and a reference value xᵣ, the signed error is e = xₘ − xᵣ. The reference value should be identified and its own uncertainty considered when relevant.

Purpose

The purpose of studying measurement errors is to understand why measured values may differ from reference values, evaluate the quality of experimental observations, identify possible biases and variations, and establish methods for obtaining more dependable results.

Importance

Measurement error analysis is essential because scientific conclusions and engineering decisions depend on the quality of measured data. It helps prevent misleading interpretations, supports instrument calibration, improves experimental methods, enables meaningful comparisons and establishes confidence in reported results.

Measurement Process

Description

Measurement error should be investigated as part of the complete measurement process rather than treated only as a numerical difference after an experiment.

Stages

StageExplanation

Define the measurand

Specify exactly which quantity is being measured, including relevant conditions, geometry, time interval, operating state or other characteristics.

Select the measurement method

Choose a procedure suitable for the quantity, required measurement range, expected uncertainty and available equipment.

Select and prepare the instrument

Check the instrument's range, resolution, operating condition, zero setting and calibration status.

Control measurement conditions

Monitor environmental and experimental influences such as temperature, humidity, vibration, pressure and electrical interference.

Collect observations

Follow a consistent procedure, take appropriate repeated observations and record the original readings with units.

Evaluate the result

Examine possible systematic effects, random variation, unusual observations and uncertainty contributions.

Report the measurement

Present the result with its unit, appropriate numerical precision and uncertainty information where required.

Distinction Between Error And Uncertainty

ConceptExplanation

Measurement error

Difference between a measured value and a reference value. It may be positive or negative and is generally not known exactly.

Measurement uncertainty

A parameter describing the dispersion of values that could reasonably be attributed to the measurand based on available information. It is non-negative.

Measurement accuracy

Closeness of agreement between a measured value and the true quantity value. It is a qualitative concept rather than a numerical quantity with a universal formula.

Measurement precision

Closeness of agreement among repeated measured values obtained under specified conditions.

Types Of Measurement Results

Direct Measurement

A quantity value obtained directly from an instrument or measurement procedure, such as a length read from a calibrated ruler.

Indirect Measurement

A quantity value calculated from other measured quantities, such as density calculated from measured mass and volume.

Single Measurement

A result obtained from one observation. Its reliability depends strongly on instrument performance, method and available uncertainty information.

Repeated Measurement

A collection of observations of the same measurand under specified conditions. The observations can be analyzed to estimate variation and the mean.

Worked Examples

TitleProblemSolutionInterpretation

Calculating the signed error

A reference length is 20.00 cm. An instrument measures the length as 20.08 cm. Calculate the signed error.

e = xₘ − xᵣ = 20.08 cm − 20.00 cm = +0.08 cm.

The positive sign indicates that the measured value is greater than the reference value by 0.08 cm.

Calculating percentage error

A reference mass is 500 g and a measurement gives 495 g. Calculate the percentage error magnitude.

Absolute error = |495 − 500| = 5 g. Relative error = 5 / 500 = 0.01. Percentage error = 0.01 × 100% = 1%.

The measured mass differs from the reference value by 1%.

Interpreting a measurement result

A measured diameter is reported as (8.42 ± 0.03) mm. Explain the report.

The estimate is 8.42 mm and the stated uncertainty is 0.03 mm. The exact interpretation of the interval depends on whether the uncertainty is standard, expanded or another specified uncertainty measure.

The uncertainty should not automatically be interpreted as a guaranteed maximum error or as a particular confidence interval without additional information.

Common Misconceptions

  • A measurement error is not always caused by a faulty instrument; the method, environment, observer and data processing can also contribute.

  • A small measurement error does not necessarily mean that the measurement uncertainty is small.

  • A highly repeatable instrument can still produce biased results.

  • Repeating measurements can help evaluate random variation but does not automatically remove systematic effects.

  • The last displayed digit of an instrument does not establish the total measurement uncertainty.

  • Measurement uncertainty is not the same as a mistake or an actual error.

  • A reference value should not be treated as perfectly exact unless its definition or supporting evidence justifies that assumption.

Applications

  • Laboratory experiments and scientific research

  • Industrial quality control and dimensional inspection

  • Calibration and verification of measuring instruments

  • Medical and clinical measurements

  • Environmental monitoring and climate observations

  • Construction and structural engineering

  • Electrical testing and electronic instrumentation

  • Manufacturing process control and product certification

Related Topics

  • Systematic, Random and Gross Errors

  • Sources and Mechanisms of Measurement Errors

  • Accuracy, Precision, Trueness and Repeatability

  • Absolute, Relative and Percentage Error

  • Measurement Uncertainty

  • Calibration and Traceability

Reference

TitleOrganizationUrl

International Vocabulary of Metrology (VIM), JCGM 200

Joint Committee for Guides in Metrology

https://www.bipm.org/en/committees/jc/jcgm/publications

Evaluation of Measurement Data — Guide to the Expression of Uncertainty in Measurement

JCGM

https://www.bipm.org/en/committees/jc/jcgm/publications

NIST/SEMATECH e-Handbook of Statistical Methods

National Institute of Standards and Technology

https://www.itl.nist.gov/div898/handbook/

Related Topic

  • SCI-REF-003-074

  • SCI-REF-003-075

  • SCI-REF-003-076

  • SCI-REF-003-078

  • SCI-REF-003-080

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Units & Measurement