A measured value may differ from a reference value by a positive or negative amount. The signed difference indicates the direction of the deviation, while absolute error expresses only its magnitude. Relative and percentage errors describe the size of the deviation compared with the reference value.
Signed error is calculated by subtracting the reference value from the measured value. A positive signed error indicates that the measured value is greater than the reference; a negative signed error indicates that it is smaller. The sign is useful when investigating systematic bias because it shows the direction of the deviation.
Absolute error is the magnitude of the signed error. It is expressed in the same unit as the measured quantity. For example, if a reference length is 10.00 cm and a measurement is 10.15 cm, the signed error is +0.15 cm and the absolute error is 0.15 cm.
Relative error compares the absolute error with the magnitude of the reference value. It is dimensionless because the numerator and denominator have the same unit. It provides a scale-independent way to describe the deviation, making it easier to compare measurements involving different units or magnitudes.
Percentage error is relative error multiplied by 100%. It is commonly used in school experiments, laboratory reports and practical measurement comparisons. The reference value must be nonzero for the standard relative and percentage error formulas. When the reference value is zero or extremely close to zero, these measures are undefined or unstable, and an alternative measure should be selected.
These formulas are most straightforward when the reference value is sufficiently reliable. If the reference itself has significant uncertainty, the calculated difference should not be interpreted as an exact error. A proper comparison should consider the uncertainty of both values and whether they refer to the same measurand under comparable conditions.
Absolute, relative and percentage error should also be distinguished from measurement uncertainty. Error is a difference from a reference value. Uncertainty characterizes the dispersion of values attributed to the measurand. A percentage error calculated from one experiment does not automatically represent the measurement uncertainty or the probability that a result is correct.
When a result is derived from multiple measured quantities, the uncertainty of the result may depend on the uncertainties of all inputs and their correlations. In such cases, a single percentage error calculation against an assumed reference may be insufficient to describe the reliability of the result.
Absolute, Relative and Percentage Error
Absolute, relative and percentage error are numerical ways of describing the difference between a measured value and a reference value. Absolute error expresses the magnitude of the difference in the same unit as the measured quantity. Relative error compares that magnitude with the reference value, while percentage error expresses the relative error as a percentage. These measures are useful for comparing measurement deviations, evaluating experimental results and communicating the scale of an error.
Signed error: e = xₘ − xᵣ
Absolute error: Eₐ = |xₘ − xᵣ|
Relative error: Eᵣ = |xₘ − xᵣ| / |xᵣ|, for xᵣ ≠ 0
Percentage error: Eₚ = [|xₘ − xᵣ| / |xᵣ|] × 100%, for xᵣ ≠ 0
If signed relative deviation is required: eᵣ = (xₘ − xᵣ) / xᵣ, for xᵣ ≠ 0.
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
xₘ | Measured quantity value | Unit of the measurand |
xᵣ | Reference quantity value | Unit of the measurand |
e | Signed measurement error | Unit of the measurand |
Eₐ | Absolute error magnitude | Unit of the measurand |
Eᵣ | Relative error magnitude | Dimensionless |
Eₚ | Percentage error | % |
Example or application
A worked example has not yet been added.
Definition
Signed Error
The measured value minus the reference value, retaining the sign of the difference.
Absolute Error
The absolute magnitude of the difference between the measured value and the reference value.
Relative Error
The absolute error divided by the magnitude of the nonzero reference value.
Percentage Error
The relative error multiplied by 100%.
Purpose
The purpose of these error measures is to quantify the difference between a measurement and a reference value in ways that communicate the magnitude, direction and relative significance of the deviation.
Importance
These measures help students and researchers evaluate experimental results, compare measurement methods, identify potential bias and communicate deviations clearly. They are especially useful when the same type of quantity is measured at different scales or with different units.
Interpretation Of Error Measures
| Measure | Information | Unit |
|---|---|---|
Signed error | Indicates both the magnitude and direction of the difference. | Same as the measurand |
Absolute error | Indicates the magnitude of the difference without direction. | Same as the measurand |
Relative error | Indicates the error magnitude in relation to the reference value. | Dimensionless |
Percentage error | Expresses the relative error as a percentage. | % |
Calculation Procedure
Identify the measured value and the reference value.
Confirm that both values represent the same physical quantity under comparable conditions.
Convert both values to the same unit.
Subtract the reference value from the measured value to obtain signed error.
Take the absolute value when the error magnitude is required.
Divide by the magnitude of the nonzero reference value to obtain relative error.
Multiply the relative error by 100 to obtain percentage error.
Report a suitable number of digits and consider the uncertainty of the reference.
Special Cases
| Case | Explanation |
|---|---|
Reference value equals zero | Relative and percentage error are undefined because division by zero is not possible. Report the absolute difference or use a suitable application-specific metric. |
Reference value is close to zero | Relative error can become extremely large and unstable. Absolute error or an alternative normalized measure may be more informative. |
Negative reference value | For error magnitude, use the absolute value of the reference in the denominator. Preserve the sign separately if the direction of the deviation matters. |
Reference value has uncertainty | The measured-reference difference is not an exact statement of the measurement error. Consider uncertainty in both values and their relationship. |
Reference and measured values use different units | Convert them to a common unit before subtraction or division. |
Worked Examples
| Title | Problem | Solution | Interpretation |
|---|---|---|---|
Absolute and percentage error in length | A reference length is 25.00 cm, while the measured length is 24.80 cm. Calculate signed error, absolute error and percentage error. | Signed error = 24.80 − 25.00 = −0.20 cm. Absolute error = 0.20 cm. Relative error = 0.20 / 25.00 = 0.008. Percentage error = 0.008 × 100% = 0.8%. | The measurement is 0.20 cm below the reference, corresponding to a deviation magnitude of 0.8%. |
Comparing errors for different quantities | Measurement A differs from its reference by 2 mm when the reference is 100 mm. Measurement B differs by 0.5 m when the reference is 50 m. Compare their percentage errors. | A: (2/100) × 100% = 2%. B: (0.5/50) × 100% = 1%. | Although the absolute errors have different magnitudes and units, Measurement A has the larger relative deviation. |
Negative signed error | A reference voltage is 12.00 V and the measured voltage is 11.70 V. | Signed error = 11.70 − 12.00 = −0.30 V. Absolute error = 0.30 V. Percentage error = (0.30/12.00) × 100% = 2.5%. | The negative signed error indicates that the measured voltage is lower than the reference. |
Zero reference value | A sensor should indicate 0.00 V under a specified zero-input condition but indicates 0.04 V. | Absolute difference = |0.04 − 0.00| = 0.04 V. Relative and percentage error using the standard reference-based formulas are undefined. | The absolute difference is useful for describing the zero offset. A different normalization may be used only if it has a clearly defined basis. |
Error And Uncertainty Distinction
Error
A difference between a measured value and a reference value.
Uncertainty
A parameter describing the dispersion of values attributed to the measurand.
Explanation
A calculated percentage error is not the same as percentage uncertainty. Percentage uncertainty is commonly formed by dividing an uncertainty by the magnitude of the measured estimate, where meaningful. It describes the relative scale of uncertainty, not a known deviation from a reference.
Common Misconceptions
Absolute error and relative error are not the same quantity.
Absolute error has units, while relative error is dimensionless.
Percentage error is not calculated by dividing by the measured value unless a particular convention explicitly defines that denominator.
The sign of signed error should not be discarded when the direction of bias matters.
Relative error is undefined when the reference value is zero.
A small percentage error does not automatically establish that a measurement is sufficiently reliable for every application.
Percentage error does not replace a complete uncertainty evaluation.
Applications
School and university laboratory experiments
Instrument calibration comparisons
Engineering measurements
Experimental physics and chemistry
Sensor testing
Manufacturing quality control
Numerical model validation
Scientific reporting
Related Topics
Introduction to Measurement Errors
Accuracy, Precision, Trueness and Repeatability
Significant Figures and Rules of Numerical Reporting
Measurement Uncertainty
Error Detection, Correction and Reduction Techniques
Reference
| Title | Organization | Url |
|---|---|---|
International Vocabulary of Metrology (VIM), JCGM 200 | Joint Committee for Guides in Metrology | https://www.bipm.org/en/committees/jc/jcgm/publications |
NIST/SEMATECH e-Handbook of Statistical Methods | National Institute of Standards and Technology | https://www.itl.nist.gov/div898/handbook/ |
Guide to the Expression of Uncertainty in Measurement | JCGM | https://www.bipm.org/en/committees/jc/jcgm/publications |
Related Topic
SCI-REF-003-073
SCI-REF-003-076
SCI-REF-003-079
SCI-REF-003-080
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Units & Measurement