✦ScienexySCIENCE KNOWLEDGE LIBRARY
reference · SCI-REF-003-096

Reference Materials, Certified Reference Materials and Standard Conditions

Reference materials provide characterized values or properties that support calibration, method validation, quality control and measurement comparability. Certified reference materials provide certified property values accompanied by uncertainty and traceability information. Standard conditions define controlled environmental or operational states needed for consistent and comparable measurements.

For a measured property x and certified reference value x_CRM, the difference is Δ = x_meas − x_CRM. A normalized comparison may use Eₙ = Δ/√(U_meas² + U_CRM²) when the expanded uncertainties are compatible and the comparison assumptions are satisfied.

Explanation

Reference materials are essential in chemical, biological, physical and industrial measurements. A reference material is sufficiently homogeneous and stable with respect to specified properties and is fit for its intended measurement use. It may be used to check instrument performance, validate a measurement procedure, evaluate method bias, establish calibration relationships or monitor long-term analytical quality. A certified reference material is a reference material accompanied by documentation issued by an authoritative body that provides one or more certified property values, their associated uncertainties and metrological traceability statements. Certification may involve carefully designed characterization studies, homogeneity assessment, stability evaluation and statistical analysis. Not every reference material is certified, and a material should not be treated as a certified reference material unless it meets the relevant requirements. Reference materials are particularly important in chemical analysis because many measured properties cannot be realized directly using a simple physical standard. Examples include certified concentrations of elements in water, composition of alloys, purity of chemical substances and biological reference preparations. Standard conditions are another important part of measurement science. Measurement results may depend on temperature, pressure, humidity, illumination, sample conditioning or other variables. A standard or reference condition defines the conditions under which a quantity or property is specified or a measurement is performed. Standard temperature and pressure are not universal single values for every scientific field; the exact conditions must be stated. For example, standard conditions used in thermodynamics, gas-volume calculations and industrial testing may differ. Measurements must therefore identify the relevant reference conditions rather than assume that all uses of the word standard refer to the same temperature and pressure.

Variables

SymbolMeaningSi Unit

x_meas

Measured property value

Unit of the property

x_CRM

Certified property value of the reference material

Same unit as x_meas

Δ

Difference between measured and certified values

Same unit as the property

U_meas

Expanded uncertainty of the measurement result

Same unit as the property

U_CRM

Expanded uncertainty associated with the certified value

Same unit as the property

Example or application

A worked example has not yet been added.

Definition

A reference material is a material sufficiently homogeneous and stable with respect to one or more specified properties, established to be fit for its intended use in a measurement process. A certified reference material is accompanied by authoritative documentation providing certified property values, associated uncertainties and metrological traceability statements.

Purpose

To provide reliable reference materials and defined measurement conditions for calibration, method validation, quality control, analytical comparison and reproducibility.

Importance

Reference materials support accurate chemical and biological analysis, industrial material testing, pharmaceutical quality, environmental monitoring, laboratory validation and international measurement comparability.

Reference Material Classification

TypeDescriptionExamples

Reference material

A material characterized sufficiently for its intended measurement use.

  • Compositionally characterized alloy

  • Water with a known conductivity value

  • Stable reference solution

Certified reference material

A reference material accompanied by certified values, associated uncertainties and traceability statements.

  • Certified elemental concentration in water

  • Certified alloy composition

  • Certified purity material

Primary measurement standard material

A material or substance used at a high metrological level where the relevant quantity value is established through an appropriate primary procedure.

  • High-purity substances used in primary measurement procedures

Working reference material

A reference material used for routine laboratory control or measurement checks.

  • Routine quality-control solution

  • Laboratory control sample

Matrix reference material

A material designed to resemble the sample matrix encountered in actual analysis.

  • Soil reference material

  • Biological tissue reference material

  • Food composition reference material

Certified Reference Material Characteristics

  • Clearly identified material and intended use.

  • Certified property values.

  • Associated measurement uncertainty.

  • Statement of metrological traceability where applicable.

  • Evidence of homogeneity assessment.

  • Evidence of stability assessment.

  • Appropriate characterization procedure.

  • Certificate or documentation specifying handling and use.

Certification Process

  • Define the intended use and target properties.

  • Select and prepare a suitable material.

  • Assess homogeneity between units and within units.

  • Assess stability during storage and transport.

  • Characterize the material using suitable measurement procedures.

  • Evaluate data from competent laboratories where appropriate.

  • Determine certified values and associated uncertainties.

  • Establish traceability statements where applicable.

  • Prepare certification documentation.

  • Establish storage, handling and validity conditions.

Uses Of Reference Materials

ApplicationDescription

Calibration

Reference materials may establish or verify measurement response and calibration relationships.

Method validation

They help evaluate method performance, bias, precision and measurement uncertainty.

Quality control

Control materials help monitor whether an analytical process remains stable over time.

Proficiency testing

Suitable materials may be used to evaluate the performance of participating laboratories.

Measurement comparability

Common reference materials help compare results from different laboratories and methods.

Standard Conditions

Description

Standard conditions are defined environmental, physical or operational conditions under which a measurement, specification or reference value is established.

Common Conditions

ConditionExamplesImportance

Temperature

  • 20 °C reference temperature for many dimensional measurements

  • Specified temperature for material testing

Temperature can change dimensions, density, electrical resistance and chemical reaction rates.

Pressure

  • Specified reference pressure in gas measurements

  • Controlled pressure in instrument testing

Pressure influences gas volume, boiling behavior and some sensor responses.

Humidity

  • Controlled laboratory relative humidity

Humidity can affect materials, electrical insulation and mass measurements.

Illumination

  • Specified lighting in optical inspection

Lighting can affect visual measurements and optical sensor response.

Sample conditioning

  • Specified drying, equilibration or conditioning procedure

Sample history and moisture content may affect measured properties.

Important Distinction

Standard temperature and pressure are context-dependent conventions. Always state the exact values and definitions used rather than assuming a universal STP condition.

Worked Example

Problem

A laboratory measures the concentration of an element in a water sample using a certified reference material.

Certified Value

10.00 mg/L

Measured Value

10.12 mg/L

Difference

Δ = 10.12 − 10.00 = +0.12 mg/L

Interpretation

The measured result is 0.12 mg/L higher than the certified value. Whether this difference is acceptable depends on the combined uncertainty, reference-material uncertainty and predefined evaluation criteria.

Handling And Storage

  • Follow the certificate's storage instructions.

  • Avoid contamination during sampling and handling.

  • Observe expiry or validity information.

  • Use the specified preparation and reconstitution procedure.

  • Allow materials to equilibrate when required.

  • Avoid repeated opening or temperature cycling when these affect stability.

  • Maintain records of lot numbers and preparation dates.

Limitations

  • A reference material may not represent every possible sample matrix.

  • Certified values apply to specified properties and stated conditions.

  • Material inhomogeneity can influence small test portions.

  • Stability may be limited by storage, transport and preparation conditions.

  • A certified reference material cannot replace a complete measurement uncertainty evaluation.

  • Standard conditions must be defined clearly because conventions may differ between fields.

Reference

  • ISO 17034:2016, General Requirements for the Competence of Reference Material Producers.

  • ISO Guide 30, Reference Materials — Selected Terms and Definitions.

  • ISO Guide 31, Reference Materials — Contents of Certificates, Labels and Accompanying Documentation.

  • ISO Guide 35, Reference Materials — Guidance for Characterization and Assessment of Homogeneity and Stability.

  • JCGM 200, International Vocabulary of Metrology (VIM).

Related Topic

  • SCI-REF-003-092

  • SCI-REF-003-093

  • SCI-REF-003-094

  • SCI-REF-003-097

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.

Suggest a correction or source · More in Units & Measurement